Pepperl+Fuchs FB8209H0907.3 Unicom Com Unit for PROFIBUS DP/DP-V1

Pepperl+Fuchs FB8209H0907.3
Item Number: FB8209H0907.3
  • Interface between the I/O modules and the PCS/PLC
  • Com unit for 80 analog or 184 digital channels
  • Communication via PROFIBUS DP
  • Installation in suitable enclosures in Zone 1
  • HART communication via PROFIBUS DP V1 or service bus
  • Configuration via FDT 1.2 DTM
  • Configuration in run (CiR) for any PCS
  • Non-volatile memory for configuration and parameter settings
  • Self configuration in redundant systems
  • Permanently self-monitoring
  • Outputs drive to safe state in case of failures
Price on Request
Quantity
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments
Relative humidity95 % non-condensing
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance
Connectionbackplane bus
Rated voltage5 V DC , only in connection with the power supplies FB92**
Power dissipation1.8 W
Environmental testEN 60068-2-14
Dimensions57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch)
Power consumption1.8 W
Relative humidityEN 60068-2-56
PROFIBUS address0 ... 126
(factory standard setting: 126)
Connectionbackplane bus
HART communicationvia PROFIBUS or service bus
Redundancyvia front connector
System informationThe module has to be mounted in appropriate backplanes (FB92**) in Zone 1, 2, or outside hazardous areas. Observe the corresponding EC-type examination certificate.
Damaging gasEN 60068-2-42
Degree of protectionIEC 60529
Cyclic process data240 bytes input and (simultaneously) 240 bytes output
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
GSE fileCGV61710.gsd/gse
Electromagnetic compatibilityNE 21
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Bus lengthmax. 1000 m (FOL, 1.5 MBaud),
max. 1000 m (copper cable, 187.5 kBd),
max. 200 m (copper cable, 1.5 MBd)
Number of stations per bus segmentmax. 31 (RS-485 standard)
Shock resistanceEN 60068-2-27
Configuration (240 bytes I/O)Standard: 80 analog, 184 digital
Universal 2I2O: 48 analog, 184 digital
Universal 4I4O: 60 analog, 120 digital
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
LED indicationLED green (power supply): On = operating, fast flash = cold start, slow flash = HCIR loading active
LED red (collective alarm): On = internal fault, flashing = no PROFIBUS connection
LED yellow (operating mode): flashing 1 (1:1 ratio) = active, normal operation; flashing 2 (7:1 ratio) = active, simulation
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
ATEX approvalPresafe 19 ATEX 14058U
Fieldbus typePROFIBUS DP/DP-V1
Supported I/O modulesall FB remote I/O modules
Connectionvia backplane
Addressingvia configuration software
Number of repeaters between Master and Slavemax. 3
Massapprox. 750 g
Fieldbus standardIEC 61158-2
Degree of protectionIP20 (module) , a separate housing is required acc. to the system description
Vibration resistanceEN 60068-2-6
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
EU-type examination certificatePresafe 19 ATEX 14058U
IECEx approvalIECEx PRE 19.0013U
Number of stations per bus linemax. 125 (PROFIBUS), max. 119 (service bus)
Occupied slots2