Pepperl+Fuchs LB1003C

Frequency / Counter Input
Pepperl+Fuchs LB1003C
362.36
One click request
Occupied slots1
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Connectionchannel I: 1+, 2-; direction: 4+, 5-
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Line fault detectioncan be switched on/off for each channel via configuration tool
Shock resistanceEN 60068-2-27
IECEx approvalBVS 09.0037X
Relative humidity95 % non-condensing
Interfacemanufacturer-specific bus to standard com unit
Minimum pulse duration; in frequency + counter mode: 12.5 ms ; otherwise 20 micro/s
Connectionbackplane bus
Power dissipation0.65 W
CertificatePF 08 CERT 1234 X
Environmental testEN 60068-2-14
Operating frequency0 ... 400 Hz ; in frequency + counter mode ... 40 Hz
ATEX approvalPTB 03 ATEX 2042
Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529
LED indicationPower LED (P) green: supply
Status LED (1) red: line fault
Relative humidityEN 60068-2-56
Damaging gasEN 60068-2-42
Connectionbackplane bus
Vibration resistanceEN 60068-2-6
Voltage8.2 V
Internal resistor1 kandOmega;
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F) , 70 В°C (non-Ex)
Dimensions16 x 100 x 102 mm (0.63 x 3.9 x 4 inch)
Codingoptional mechanical coding via front socket
Massapprox. 90 g
Number of channels1
Degree of protectionIP20 when mounted on backplane
Switching point/switching hysteresis1.2 ... 2.1 mA / В± 0.2 mA
Rated voltage12 V DC , only in connection with the power supplies LB9***
Connectionremovable front connector with screw flange (accessory)
wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
System informationThe module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity.
For use in hazardous areas (e. g. Zone 2 or Zone 22) the module must be installed in an appropriate enclosure.
Power consumption0.65 W
in international format without spaces