Pepperl+Fuchs LB5001A

RTD Converter
Pepperl+Fuchs LB5001A
391.51
One click request
Vibration resistanceEN 60068-2-6
LED indicationPower LED (P) green: supply
Status LED (1) red: line fault
Dimensions16 x 100 x 102 mm (0.63 x 3.9 x 4 inch)
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Number of channels1
CertificatePF 08 CERT 1234 X
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
Electromagnetic compatibilityNE 21
Codingoptional mechanical coding via front socket
Smallest span20 andOmega; for 0.1 % accuracy
Massapprox. 90 g
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance
Connectionbackplane bus
Rated voltage12 V DC , only in connection with the power supplies LB9***
Slide-wire sensor10 ... 400 andOmega;
Power consumption0.4 W
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Measurement range10 ... 400 andOmega; (500 andOmega; incl. line resistance)
Damaging gasEN 60068-2-42
Occupied slots1
Shock resistanceEN 60068-2-27
Power dissipation0.4 W
Lead resistancemax. 50 andOmega; per strand
Measuring current200 andmicro;A
Connectionbackplane bus
Degree of protectionIP20 when mounted on backplane
Environmental testEN 60068-2-14
IECEx approvalBVS 09.0037X
System informationThe module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity.
For use in hazardous areas (e. g. Zone 2 or Zone 22) the module must be installed in an appropriate enclosure.
Relative humidityEN 60068-2-56
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Linearity error0.1 %
Relative humidity95 % non-condensing
Conversion timemax. 20 ms without LFD max. 150 ms with LFD
Connection2-wire connection: 5, 6
3-wire connection: 1, 5, 6
4-wire connection: 1, 2, 5, 6
Line fault detectioncan be switched on/off for each channel via configuration tool
Degree of protectionIEC 60529
Connectionremovable front connector with screw flange (accessory)
wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Interfacemanufacturer-specific bus to standard com unit
in international format without spaces