Pepperl+Fuchs LB6017E Digital Output with Shutdown Input

Pepperl+Fuchs LB6017E
Item Number: LB6017E
  • 2-channel
  • Outputs Ex ic
  • Installation in Zone 2 or safe area
  • Line fault detection switched on and off
  • Positive or negative logic selectable
  • Simulation mode for service operations (forcing)
  • Permanently self-monitoring
  • Output with watchdog
  • Output with bus-independent safety shutdown
  • Module can be exchanged under voltage (hot swap)
Price on Request
Quantity
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments
Vibration resistanceEN 60068-2-6
Massapprox. 150 g
Response time10 ms (depending on bus cycle time)
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance
Relative humidity95 % non-condensing
System informationThe module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity.
For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure.
Degree of protectionIP20 when mounted on backplane
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Degree of protectionIEC 60529
Electromagnetic compatibilityNE 21
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Environmental testEN 60068-2-14
Current limit50 mA both channels parallel 100 mA
Line fault detectioncan be switched on/off for each channel via configuration tool also when turned off (every 2.5 s the valve is turned on for 2 ms)
Power consumption2.7 W
ATEX approvalEXA 16 ATEX 0035X
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
Connectionbackplane bus
LED indicationPower LED (P) green: supply
Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit
Status LED (1, 2) red: line fault (lead breakage or short circuit) , yellow: state of digital I/O (0/1)
Mode LED (M) white: Parallel operation of outputs
Relative humidityEN 60068-2-56
Shock resistanceEN 60068-2-27
Rated voltageUse only in connection with the power supplies LB9***
Connectionbackplane bus
Connectionremovable front connector with screw flange (accessory)
wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Occupied slots1
Open loop voltage16.5 V , both channels parallel 16.5 V
Number of channels2
Interfacemanufacturer-specific bus to standard com unit
Damaging gasEN 60068-2-42
Dimensions16 x 100 x 102 mm (0.63 x 3.9 x 4 inch)
Power dissipation1.7 W
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
EU-type examination certificateEXA 16 ATEX 0035X
Internal resistor131 Ω , both channels parallel 66 Ω
Watchdogwithin 0.5 s the device goes in safe state, e.g. after loss of communication
Codingoptional mechanical coding via front socket
Connectionchannel I: 1+, 4/5/6/8-; channel II: 7+, 4/5/6/8-