Pepperl+Fuchs NJ5-11-N-15M Inductive sensor

Pepperl+Fuchs NJ5-11-N-15M
Item Number: NJ5-11-N-15M
  • Comfort series
  • 5 mm non-flush
  • Usable up to SIL 2 acc. to IEC 61508
Price on Request
Quantity
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments
Effective internal inductancemax. 50 µH ; a cable length of 10 m is considered.
Connection typecable PVC , 15 m
Assured operating distance0 ... 4.05 mm
CCC approvalCCC approval / marking not required for products rated ≤36 V
Reduction factor r304 0.85
Housing materialPVDF
Output type2-wire
CE marking[*PD-Z02585A*]
Output typeNAMUR
Reduction factor rCu 0.3
Rated operating distance5 mm
CE marking[*PD-Z02585A*]
Nominal voltage8 V
Hysteresistyp. %
MTTFd11774 a
Installationnon-flush
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Switching frequency0 ... 3000 Hz
Effective internal inductancemax. 50 µH
A cable length of 10 m is considered.
Switching functionNormally closed (NC)
Mission Time (TM)20 a
StandardsEN 60079-0:2012+A11:2013, EN 60079-11:2012
Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
Use in the hazardous areasee instruction manuals
Diagnostic Coverage (DC)0 %
Degree of protectionIP68
StandardsEN 60079-0:2012+A11:2013, EN 60079-11:2012
Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
Maximum permissible ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate.
Reduction factor rAl 0.4
Appropriate typeNJ 5-11-N...
ATEX marking II 1D Ex ia IIIC T135В°C Da
The Ex-related marking can also be printed on the enclosed label.
ATEX marking II 2G Ex ia IIC T6…T1 Gb
The Ex-related marking can also be printed on the enclosed label.
Sensing facePVDF
Effective internal capacitancemax. 45 µF
A cable length of 10 m is considered.
UL approvalcULus Listed, General Purpose
Effective internal capacitancemax. 45 nF ; a cable length of 10 m is considered.
Appropriate typeNJ 5-11-N...
Core cross-section0.34 mm2
Ambient temperature-25 ... 100 В°C (-13 ... 212 В°F)

Comments

No comments yet