Operating voltage10 ... 30 V DC
Operation indicatorPower on: static illumination , Undervoltage indicator: Green LED, pulsing (approx. 0.8 Hz) , short-circuit : LED green flashing (approx. 4 Hz)
Mission Time (TM)20 a
Voltage drop 2 V DC at 100 mA ; 0.7 V at 10 mA
Degree of protectionIP50
Ripple10 %
Pre-fault indication output1 NPN, short-circuit protected open collector
Diagnostics indicator7-segment display
CCC approvalCCC approval / marking not required for products rated 36 V
Ambient temperature-10 ... 55 В°C (14 ... 131 В°F)
Sensor rangeup to 150 mm (KLR-C02-2,2-2,0-K146)
Ambient light limit10000 Lux
Storage temperature-20 ... 70 В°C (-4 ... 158 В°F)
Gang mountingmaximum 20 units
Switching currentmax. 100 mA , resistive load
Function indicatorLED yellow: static illumination switching state, flashes when falling short of the stability control
Light sourceLED
Light typemodulated visible red light , 660 nm
Diagnostic Coverage (DC)0 %
Switching typelight/dark on selectable programmable
Switching voltagemax. 30 V DC
Switching frequencyHigh speed mode: 16 kHz , Standard mode: 3 kHz , High resolution: 250 Hz ~ 3 kHz (selection by the sensor), Automatic: 250 Hz , Glass mode: 250 Hz
Signal output1 NPN, short-circuit protected open collector
Housing height34.5 mm
UL approvalcULus Listed, Class 2 Power Source, Type 1 enclosure
No-load supply current 30 mA
Mass45 g
Detection rangeup to 450 mm (KLE-C01-2,2-2,0-K116)
Control elementsButton (Mode) for menu choice ; Button (Set) for Teach-In ; Button (Up/Down) for fine adjusting and parameterization
Response timeHigh speed mode: 30 micro/s , Standard mode: 160 micro/s , High resolution: 2 ms , Automatic: 160 micro/s ~ 2 ms (choice by the sensor), Glass mode: 2 ms
Repeat accuracy 0.5 % of adjusted sensor range
MTTFd500 a
Housing depth62.3 mm
Connection2 m PVC cable, 4 x 0,14 mm2
Housing width9 mm
Timer functionON-delay, OFF-delay, one shot, pulse extension ; adjustable 0 ... 999 ms in 1 ms increments

Comments