Pepperl+Fuchs TopScan-S-T0V1-MS/L750 Active infrared scanner

Pepperl+Fuchs TopScan-S-T0V1-MS/L750
Item Number: TopScan-S-T0V1-MS/L750
  • Moving presence sensor for swing doors
  • Configurable for a wide range of door leaf widths
  • Category 2, tested and certified to DIN 18650/EN 16005
  • Modular construction with master/slave modules
  • Safe function even on difficult floors
  • Each beam can be adjusted individually
  • Easy adjustment of transmitter for hinge side/ opposite hinge side
  • Double-beam version
Price on Request
Quantity
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments
Test inputactive at U = -3 VDC to +1 VDC inactive at U = +4 VDC to 30 VDC
Relative humidityHumidity at 20 В°C: < 90 %
Humidity at 60 В°C: < 50 %
Degree of protectionIP52 , IP54 Optional (with special seal)
Black/White difference (6 %/90 %)< 2 % at 2000 mm sensor range
Diagnostic Coverage (DC)90 %
Connectionscrew terminals ; Cable cross-section 0.3 mm2 ... 1.3 mm2 (AWG26-16), single-stranded/multistranded CU
Reference targetMinimum degree of reflection of the floor: 6 %
Minimum degree of reflection to objects being detected: 0 %
Response time 70 ms
Housing length L750 mm
Mission Time (TM)20 a
TГњV approvalTГњV NORD
MTTFd880 a per module
Detection range min.0 ... 1500 mm
Light sourceIRED
Product standardEN 12978 ; EN 16005 ; DIN 18650
CategoryCat. 2
Switching voltage5 V ... 30 V AC/DC
CCC approvalCCC approval / marking not required for products rated 36 V
Light typemodulated infrared light 875 nm
Signal outputRelay, 1 alternator
Switching typeRelay de-energized at object inside the scanning range
Control elementsSensing range adjuster ; Adjuster for edge monitoring left/right
Operating modeBackground evaluation
Detection range max.0 ... 2500 mm
Functional safetyISO 13849-1
Performance level (PL)PL c
Mounting heightmax. 2500 mm
Diameter of the light spot1.1 cm x 8.3 cm at 2000 mm sensor range
Safety Integrity Level (SIL)SIL 1
No-load supply current140 mA
NoteSafety fuse 1 A (slow-blow) according to IEC 60127-2 Sheet 1
Recommendation: after a short circuit, check that the device is functioning correctly.
Number of beams2 (number of built-in sensor modules AIR)
Operating voltage24 V DC +/- 20 %
ResolutionReference object CA DIN 186850-1/EN 16005 in all applicable locations
Function indicatorLED red/green
Ambient temperature-10 ... 50 В°C (14 ... 122 В°F)
Switching currentmax. 300 mA

Comments

No comments yet

Write a comment

captcha
in international format without spaces