Pepperl+Fuchs UC6000-30GM-E7R2-V15 Ultrasonic sensor

Pepperl+Fuchs UC6000-30GM-E7R2-V15
Item Number: UC6000-30GM-E7R2-V15
  • Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 3000
  • 2 programmable switch outputs
  • Hysteresis mode selectable
  • Window mode selectable
  • Synchronization options
  • Adjustable acoustic power and sensitivity
  • Temperature compensation
Price on Request
Quantity
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments
Temperature/TEACH-IN connectorTemperature compensation , Switch points programming , output function setting
Ambient temperature-25 ... 70 В°C (-13 ... 158 В°F)
CSA approvalcCSAus Listed, General Purpose
Adjustment range400 ... 6000 mm
Transducer frequencyapprox. 65 kHz
Temperature influence 2 % from full-scale value (with temperature compensation)
0.2 %/K (without temperature compensation)
Response delay285 ms minimum
850 ms factory setting
Output type2 switch outputs NPN, NO/NC, programmable
LED yellow 1solid: switching state switch output 1
flashing: program function
Mass270 g
Interface typeRS 232, 9600 Bit/s , no parity, 8 data bits, 1 stop bit
Voltage drop 2.5 V
LED greensolid: Power-on
flashing: Standby mode or program function object detected
No-load supply current 50 mA
Storage temperature-40 ... 85 В°C (-40 ... 185 В°F)
Repeat accuracy 0.1 % of full-scale value
Connection typeConnector M12 x 1 , 5-pin
Rated operating current200 mA , short-circuit/overload protected
Synchronizationbi-directional
0 level -UB...+1 V
1 level: +4 V...+UB
input impedance: > 12 KOhm
synchronization pulse: 100 micro/s, synchronization interpulse period: 2 ms
Degree of protectionIP65
Operating voltage10 ... 30 V DC , ripple 10 %SS
LED redsolid: temperature/program plug not connected
flashing: fault or program function object not detected
Sensing range350 ... 6000 mm
Switching frequency 0.5 Hz
CCC approvalCCC approval / marking not required for products rated 36 V
Standard target plate100 mm x 100 mm
LED yellow 2solid: switching state switch output 2
flashing: program function
Range hysteresis1 % of the adjusted operating range (default settings), programmable
Dead band0 ... 350 mm
UL approvalcULus Listed, General Purpose

Comments

No comments yet