Sick AFS60A-S4AL065536 AFS60 Absolute encoder

Sick AFS60A-S4AL065536
Item Number: AFS60A-S4AL065536
  • High-resolution absolute encoders with up to 30 bits (AFM60) or up to 18 bits (AFS60)
  • Face mount flange, servo flange, blind or through hollow shaft
  • SSI, SSI + Incremental or SSI + Sin/Cos interface
402.69
Quantity
-
+
Total price: 402.69
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments

Sick AFS60A-S4AL065536 is outdated.

Specification:

Part Number1038172
Power consumption:0.5 W (without load)
Operating torque:0.3 Ncm (20 °C)
Moment of inertia of the rotor:6.2 gcm²
Max. number of revolutions:1
Permissible Load capacity of shaft:40 N (axial), 80 N (radial)
SET (electronic adjustment):H-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V)
Measuring step:0.014 ° 360 ° / number of steps
Resolution power:65,536 x 1
Resistance to vibration:20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
Clock frequency:2 MHz
Storage temperature range:-40 °C ... 100 °C, without package
Shaft diameter:10 mm
:Face mount flange
Code sequence:CW/CCW, parameter adjustable
CW/CCW (counting sequence when turning):L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V)
Interface signals:Clock +, Clock -, Data +, Data-
Maximum operating speed:9,000 /min
Start up torque:0.5 Ncm (20 °C)
Electrical interface:SSI/Gray
Mechanical interface:Solid shaft with flat, Face mount flange
Max. angular acceleration:500,000 rad/s²
Code type:Gray
Max. number of steps per revolution:65,536
Resistance to shocks:60 g, 6 ms (according to EN 60068-2-27)
Reverse polarity protection:1
MTTFd: mean time to dangerous failure:250 a (EN ISO 13849-1)
EMC:(according to EN 61000-6-2 and EN 61000-6-3)
Bearing lifetime:3.0 x 10^9 revolutions
Type of mounting shaft:Solid shaft with flat
Initialization time:50 ms
Connection type:Cable, 8-wire, universal, 3 m
Working temperature range:-30 °C ... 100 °C
Enclosure rating:IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side
Error limits:± 0.03 °
Repeat accuracy:0.002 °
Measuring step deviation:± 0.002 °
Permissible relative humidity:90 % (condensation of the optical scanning not permitted)
Operating voltage range:4.5 V DC ... 32 V DC