Sick AFS60B-TDAA000360 AFS60 Absolute encoder

Sick AFS60B-TDAA000360
Item Number: AFS60B-TDAA000360
  • High-resolution absolute encoders with up to 30 bits (AFM60) or up to 18 bits (AFS60)
  • Face mount flange, servo flange, blind or through hollow shaft
  • SSI, SSI + Incremental or SSI + Sin/Cos interface
435.60
Quantity
-
+
Total price: 435.60
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments

Specification:

Part Number1065724
Permissible relative humidity:90 % (condensation of the optical scanning not permitted)
Electrical interface:SSI/Gray
Clock frequency:2 MHz
Maximum operating speed:9,000 /min
Connection type:Connector M23, 12-pin, radial
Max. angular acceleration:500,000 rad/s²
Error limits:± 0.05 °
Resistance to shocks:70 g, 6 ms (according to EN 60068-2-27)
Permissible movement axial static/dynamic:± 0.5 mm, ± 0.2 mm
Max. number of steps per revolution:360
Resistance to vibration:30 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
Resolution power:360 x 1
Operating torque:0.6 Ncm (20 °C)
Shaft diameter:10 mm
Mechanical interface:Through hollow shaft
Code sequence:CW/CCW, parameter adjustable
Moment of inertia of the rotor:40 gcm²
Start up torque:0.8 Ncm (20 °C)
Power consumption:0.5 W (without load)
Interface signals:Clock +, Clock -, Data +, Data-
SET (electronic adjustment):H-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V)
Measuring step deviation:± 0.08 °
Initialization time:50 ms
MTTFd: mean time to dangerous failure:250 a (EN ISO 13849-1)
Permissible movement radial static/dynamic:± 0.3 mm, ± 0.1 mm
Type of mounting shaft:Through hollow shaft
Code type:Gray
Working temperature range:-30 °C ... 100 °C
Mass:0.2 kg
Operating voltage range:4.5 V DC ... 32 V DC
Resolution:8.49 bit
Reverse polarity protection:1
Max. number of revolutions:1
CW/CCW (counting sequence when turning):L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V)
Enclosure rating:IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side
EMC:(according to EN 61000-6-2 and EN 61000-6-3)
Repeat accuracy:0.002 °
Storage temperature range:-40 °C ... 100 °C, without package
Bearing lifetime:3.0 x 10^9 revolutions
Measuring step:0.01 °

Comments

No comments yet

Write a comment