Sick AFS60E-TDAA001024 AFS60 Absolute encoder

Sick AFS60E-TDAA001024
Item Number: AFS60E-TDAA001024
  • High-resolution absolute encoders with up to 30 bits (AFM60) or up to 18 bits (AFS60)
  • Face mount flange, servo flange, blind or through hollow shaft
  • SSI, SSI + Incremental or SSI + Sin/Cos interface
398.82
Quantity
-
+
Total price: 398.82
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments

Sick AFS60E-TDAA001024 is outdated.

Specification:

Part Number1038057
Interface signals:Clock +, Clock -, Data +, Data-
Shaft diameter:10 mm
MTTFd: mean time to dangerous failure:250 a (EN ISO 13849-1)
Start up torque:0.8 Ncm (20 °C)
Permissible movement radial static/dynamic:± 0.3 mm, ± 0.1 mm
Type of mounting shaft:Through hollow shaft
Measuring step:0.09 ° 360 ° / number of steps
Max. angular acceleration:500,000 rad/s²
CW/CCW (counting sequence when turning):L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V)
Max. number of revolutions:1
Resolution power:1,024 x 1
Connection type:Connector M23, 12-pin, radial
Enclosure rating:IP 65 (according to IEC 60529), housing side, IP 65 (according to IEC 60529), shaft side
Electrical interface:SSI/Gray
Maximum operating speed:9,000 /min
Resistance to shocks:50 g, 6 ms (according to EN 60068-2-27)
Code type:Gray
Mass:0.2 kg
SET (electronic adjustment):H-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V)
Mechanical interface:Through hollow shaft
Error limits:± 0.3 °
Operating voltage range:4.5 V DC ... 32 V DC
Repeat accuracy:0.002 °
Operating torque:0.6 Ncm (20 °C)
Storage temperature range:-40 °C ... 100 °C, without package
Code sequence:CW/CCW, parameter adjustable
Resistance to vibration:20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
Bearing lifetime:3.0 x 10^9 revolutions
Power consumption:0.5 W (without load)
Max. number of steps per revolution:1,024
Clock frequency:1 MHz
Initialization time:50 ms
Moment of inertia of the rotor:40 gcm²
Permissible relative humidity:90 % (condensation of the optical scanning not permitted)
Reverse polarity protection:1
Working temperature range:0 °C ... 85 °C
EMC:(according to EN 61000-6-2 and EN 61000-6-3)
Permissible movement axial static/dynamic:± 0.5 mm, ± 0.2 mm
Measuring step deviation:± 0.2 °

Comments

No comments yet

Write a comment