Sick DFS60E-THEM01024 DFS60 Incremental Encoder

Sick DFS60E-THEM01024
Item Number: DFS60E-THEM01024
  • Compact installation depth
  • High resolution up to 16 bits
  • Optionally programmable: Output voltage, zero pulse position, zero pulse width and number of pulses
225.54
Quantity
-
+
Total price: 225.54
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments

Sick DFS60E-THEM01024 is outdated.

Specification:

Part Number1053730
Shaft diameter:15 mm
Power consumption:0.5 W (without load)
Mass:0.2 kg
MTTFd: mean time to dangerous failure:300 a (EN ISO 13849-1)
Enclosure rating:IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side
Reference signal, position:90 °, electronically, gated with A and B
Operating voltage range:10 V ... 32 V
Permissible movement radial static/dynamic:± 0.3 mm, ± 0.1 mm
Measuring step deviation:± 0.2 °
Permissible relative humidity:90 % (condensation of the optical scanning not permitted)
Moment of inertia of the rotor:40 gcm²
Bearing lifetime:3.6 x 10^10 revolutions
Maximum output frequency:300 kHz
Operating torque:0.6 Ncm (+20 °C)
Pulses per revolution:1,024
Resistance to vibration:20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
EMC:(according to EN 61000-6-2 and EN 61000-6-3)
Reference signal, number:1
Maximum operating speed:9,000 /min
Working temperature range:0 °C ... +85 °C
Max. angular acceleration:500,000 rad/s²
Electrical interface:10 V ... 32 V, HTL/Push pull, Cable, 8-pin, universal, 5 m
Storage temperature range:-40 °C ... +100 °C, without package
Start up torque:0.8 Ncm (+20 °C)
Connection type:Cable, 8-wire, universal, 5 m
Resistance to shocks:50 g (according to EN 60068-2-27)
Permissible movement axial static/dynamic:± 0.5 mm, ± 0.2 mm
Shaft material:Metal
Error limits:± 0.3 °
Load current max.:30 mA
Initialization time:40 ms
Mechanical interface:Through hollow shaft
Measuring step:90 ° / electronically/number of lines

Comments

No comments yet

Write a comment