Sick ICR847-2E0030 Image-based code readers

Sick ICR847-2E0030
Item Number: ICR847-2E0030
  • Configure with live image and auto setup
  • High resolution, 1,2 megapixel imager for large field of view with high density codes
  • Fast, omni-directional reading of printed and direct part marked 1D and 2D codes
Price on Request
Quantity
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments

Sick ICR847-2E0030 is outdated.

Specification:

Part Number1051094
Dimensions:112 mm x 80 mm x 39 mm
Housing color:Light blue (RAL 5012)
Reading distance:100 mm ... 230 mm
No. of characters per reading interval:4,000
Sensor:CMOS matrix sensor
Light source:Visible red light (lighting LEDs, 617 nm, ± 15 nm)
Bar code types:Interleaved 2 of 5, Codabar, Code 128, Code 39, GS1-128 / EAN 128, Pharmacode, UPC / GTIN / EAN
Focus position:175 mm
Remark (DeviceNet):Optional via external connection module (CDM + CMF)
Electrical connection:1 x M12 cylindrical connector (4-pin female connector, Ethernet)
1
Operating voltage:15 V DC ... 30 V DC
2D code types:Data Matrix ECC200, GS1 Data-Matrix, QR code
Switching inputs:2
Remark (PROFIBUS DP):Optional via external connection module (CDM + CMF)
No. of codes per scan:1 ... 50
Protocol (Ethernet):TCP/IP, FTP (image transmission), PROFINET (optional via external connection module CDM)
PROFIBUS DP:+
MTBF:75,000 h
Housing:Die-cast zinc
Ambient light safety:2,000 lx
Reading pulse:Non-powered, Switching inputs, Serial interface
Reading field:Front
Optical indicators:6 LEDs (status displays)
Switching outputs:2 (Result 1 NPN, Result 2 PNP)
Data transmission rate (Ethernet):10/100 Mbit
Data transmission rate (CAN bus):10 kbit/s ... 1 Mbit/s
Permissible relative humidity:± 90 %, non-condensing
Function (Serial (RS-232)):Host, AUX
Vibration resistance:EN 60068-2-6
DeviceNet:+
Data transmission rate (Serial (RS-232)):300 Baud ... 57,600 Baud, AUX: 9,600 Baud
Electromagnetic compatibility (EMC):EN 61000-6-2 / EN 61000-6-4
Protocol (CAN bus):CANopen, CSN (SICK CAN Sensor Network)
Weight:900 g, with connecting cable
Protection class:III (EN 61140)
Function (CAN bus):SICK CAN sensor network (Master/Slave, Multiplexer)
No. of codes per reading interval:1 ... 50
Focus:Fixed focus
Laser class:1 (EN 60825-1)
Serial (RS-232):+
Function (Ethernet):Host, AUX, image transmission
Power consumption:13 W
Ambient operating temperature:0 °C ... +40 °C
Ethernet:+
Version:Extended Long Range
Enclosure rating:IP 65 (EN 60529)
IP 30
Shock resistance:EN 60068-2-27
Storage temperature:-20 °C ... +70 °C
Code resolution:≥0.2 mm
Sensor resolution:1,280 px x 960 px x 1.2 megapixel )
CAN bus:+
Acoustic indicators:Beeper/buzzer (can be switched off, can be assigned a function to signal a result)

Comments

No comments yet

Write a comment

People also buy