Sick MLG1-0140F812 Measuring automation light grids

Sick MLG1-0140F812
Item Number: MLG1-0140F812
  • Resolutions of 10 / 20 / 30 / 50 mm and customer-specific resolutions
  • Working range up to 8.5 m
  • Detection heights of over 3 m and up to 240 beams possible
Price on Request
Quantity
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments

Specification:

Part Number1022147
Initialization time:1 s
Beam separation:10 mm
Detection height:140 mm
Inputs:1 x PNP
Protection class:III
Output load capacitive:100 nF
Ripple:< 5 Vpp
Maximum range :7 m
Response time :Parallel beam: ≥3.25 ms
Power consumption sender :170 mA
Shock load:10 g / IEC 68-2-29 / 16 ms
Minimum detectable object (MDO) :Parallel beam: ≥15 mm
Output current Imax.:100 mA
Indication:7-segment display, LED
Ambient light safety :Direct: ≥12,500 lx, Indirect: ≥50,000 lx
Output load inductive:1 H
Housing material:Aluminum
Technology:Sender/receiver
Power consumption receiver :145 mA
Working range :5 m
Vibration resistance:5 g, 10 Hz ... 55 Hz (IEC 68-2-6)
Configuration:Parameterization interface (measuring)
Wave length:IR 880 nm
Weight:0.822 kg
Power consumption:170 mA
Task:Measurement light grid
Ambient temperature:Operation: -25 ... +55 °C, Storage: -40 ... +70 °C
Minimum range:Parallel beam: ≥0 mm
Switching output:3 x PNP
Supply voltage Vs :DC 18 V ... 30 V
Number of beams:15
Synchronization:Cable
Dimensions (W x H x D):34 mm x 214 mm x 29 mm
Front screen:PMMA
Connection type:Male connector M12, 8-pin
EMC:EN 60947-5-2
Enclosure rating:IP 65
Circuit protection:Output Q short-circuit protected, Interference suppression, VS connections reverse-polarity protected

Comments

No comments yet

Write a comment

in international format without spaces