Sick MLG1-2240P811 Measuring automation light grids

Sick MLG1-2240P811
Item Number: MLG1-2240P811
  • Integrated PROFIBUS interface
  • Resolutions of 10 / 20 / 30 / 50 mm and customer-specific resolutions
  • Working range up to 8.5 m
Price on Request
Quantity
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments

Specification:

Part Number1028536
Configuration:GSD data file
Output load capacitive:100 nF
Ambient light safety :Direct: ≥12,500 lx, Indirect: ≥50,000 lx
Indication:7-segment display, LED
Shock load:10 g / IEC 68-2-29 / 16 ms
Synchronization:Cable
Wave length:IR 880 nm
Initialization time:1 s
Output load inductive:1 H
Vibration resistance:5 g, 10 Hz ... 55 Hz (IEC 68-2-6)
Minimum detectable object (MDO) :Parallel beam: ≥15 mm
Power consumption receiver :775 mA
Dimensions (W x H x D):34 mm x 2,314 mm x 29 mm
Minimum range:Parallel beam: ≥0 mm
Switching output:1 x PNP
Beam separation:10 mm
EMC:EN 60947-5-2
Protection class:III
Working range :5 m
Maximum range :7 m
Weight:5.652 kg
Power consumption sender :590 mA
Connection type:Male connector M12, 8-pin
Enclosure rating:IP 65
Response time :Parallel beam: ≥34.75 ms
Power consumption:590 mA
Output current Imax.:100 mA
Ripple:< 5 Vpp
Circuit protection:Output Q short-circuit protected, Interference suppression, VS connections reverse-polarity protected
Detection height:2,240 mm
Technology:Sender/receiver
Housing material:Aluminum
Number of beams:225
Task:Measurement light grid
Front screen:PMMA
Inputs:1 x PNP
Ambient temperature:Operation: -25 ... +55 °C, Storage: -40 ... +70 °C
Supply voltage Vs :DC 18 V ... 30 V

Comments

No comments yet

Write a comment

in international format without spaces