Sick MLG2-3140I212

Measuring automation light grids
Sick MLG2-3140I212
Price on Request
One click request

Specification:

Part Number1022096
Front screen:PMMA
Configuration:Parameterization interface (measuring)
Enclosure rating:IP 65
Power consumption receiver :574 mA
Ambient light safety :Direct: ≥12,500 lx, Indirect: ≥50,000 lx
Inputs:2 x PNP
Initialization time:1 s
Ripple:< 5 Vpp
Minimum range:Parallel beam: ≥0 mm
Housing material:Aluminum
Ambient temperature:Operation: -25 ... +55 °C, Storage: -40 ... +70 °C
EMC:EN 60947-5-2
Synchronization:Cable
Working range :5 m
Output current Imax.:100 mA
Response time :Parallel beam: ≥24.7 ms
Number of beams:158
Connection type:Terminals
Wave length:IR 880 nm
Vibration resistance:5 g, 10 Hz ... 55 Hz (IEC 68-2-6)
Output load capacitive:100 nF
Shock load:10 g / IEC 68-2-29 / 16 ms
Circuit protection:Output Q short-circuit protected, Interference suppression, VS connections reverse-polarity protected
Weight:7.722 kg
Technology:Sender/receiver
Detection height:3,140 mm
Output load inductive:1 H
Task:Measurement light grid
Maximum range :7 m
Protection class:III
Switching output:4 x PNP
Dimensions (W x H x D):34 mm x 3,335 mm x 29 mm
Minimum detectable object (MDO) :Parallel beam: ≥25 mm
Power consumption sender :456 mA
Power consumption:456 mA
Beam separation:20 mm
Supply voltage Vs :DC 18 V ... 30 V
Indication:7-segment display, LED
in international format without spaces