Sick MLG3-0270F812 Measuring automation light grids

Sick MLG3-0270F812
Item Number: MLG3-0270F812
  • Resolutions of 10 / 20 / 30 / 50 mm and customer-specific resolutions
  • Working range up to 8.5 m
  • Detection heights of over 3 m and up to 240 beams possible
Price on Request
Quantity
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments

Sick MLG3-0270F812 is outdated.

Specification:

Part Number1029455
Output current Imax.:100 mA
Power consumption:160 mA
Weight:1.121 kg
Indication:7-segment display, LED
Response time :Parallel beam: ≥2.5 ms
Ambient light safety :Direct: ≥12,500 lx, Indirect: ≥50,000 lx
Housing material:Aluminum
Configuration:Parameterization interface (measuring)
Output load capacitive:100 nF
Protection class:III
Ambient temperature:Operation: -25 ... +55 °C, Storage: -40 ... +70 °C
Front screen:PMMA
Detection height:270 mm
Minimum detectable object (MDO) :Parallel beam: ≥35 mm
Circuit protection:Output Q short-circuit protected, Interference suppression, VS connections reverse-polarity protected
Enclosure rating:IP 65
Beam separation:30 mm
Dimensions (W x H x D):34 mm x 364 mm x 29 mm
Output load inductive:1 H
Connection type:Male connector M12, 8-pin
Shock load:10 g / IEC 68-2-29 / 16 ms
Supply voltage Vs :DC 18 V ... 30 V
Power consumption receiver :130 mA
Working range :5 m
Synchronization:Cable
Minimum range:Parallel beam: ≥0 mm
Switching output:3 x PNP
Wave length:IR 880 nm
Inputs:1 x PNP
Power consumption sender :160 mA
Number of beams:10
Maximum range :7 m
Technology:Sender/receiver
Ripple:< 5 Vpp
Vibration resistance:5 g, 10 Hz ... 55 Hz (IEC 68-2-6)
EMC:EN 60947-5-2
Task:Measurement light grid
Initialization time:1 s

Comments