Sick MLG5-2350F511 Measuring automation light grids


Item Number: MLG5-2350F511
- Up to 3 x PNP or NPN switching outputs
- Resolutions of 10 / 20 / 30 / 50 mm and customer-specific resolutions
- Working range up to 8.5 m
- Overview
- Datasheet
- Alternative numbers
- Comments
Sick MLG5-2350F511 is outdated.
Specification:
Part Number | 1040304 |
Minimum range: | Parallel beam: ≥0 mm |
Minimum detectable object (MDO) : | Parallel beam: ≥55 mm |
Ambient temperature: | Operation: -25 ... +55 °C, Storage: -40 ... +70 °C |
Configuration: | Standard (switching) |
Supply voltage Vs : | DC 18 V ... 30 V |
Output current Imax.: | 100 mA |
Enclosure rating: | IP 65 |
Vibration resistance: | 5 g, 10 Hz ... 55 Hz (IEC 68-2-6) |
Housing material: | Aluminum |
Number of beams: | 48 |
Wave length: | IR 880 nm |
Task: | Measurement light grid |
Technology: | Sender/receiver |
Connection type: | Male connector M12, 5-pin |
Switching output: | 1 x PNP |
Initialization time: | 1 s |
Ambient light safety : | Direct: ≥12,500 lx, Indirect: ≥50,000 lx |
Front screen: | PMMA |
Response time : | Parallel beam: ≥8.2 ms |
Power consumption sender : | 236 mA |
Ripple: | < 5 Vpp |
Power consumption: | 236 mA |
Output load capacitive: | 100 nF |
Detection height: | 2,350 mm |
Power consumption receiver : | 244 mA |
EMC: | EN 60947-5-2 |
Maximum range : | 7 m |
Working range : | 5 m |
Output load inductive: | 1 H |
Protection class: | III |
Beam separation: | 50 mm |
Weight: | 5.905 kg |
Synchronization: | Cable |
Shock load: | 10 g / IEC 68-2-29 / 16 ms |
Indication: | 7-segment display, LED |
Dimensions (W x H x D): | 34 mm x 2,464 mm x 29 mm |
Circuit protection: | Output Q short-circuit protected, Interference suppression, VS connections reverse-polarity protected |
People also buy
Comments
No comments yet