actual range Sb (FSE 200C1002)90 mm
sensing distance Tw (FUE 200C1003)25 mm
light sourcepulsed red LED
output circuitanalog 1 ... 5 VDC
operating temperature-20 ... +60 °C
FX0-GCC100200 CCLINK GATEWAY art. 1085195
FX0-GDEV00000 FLEXISOFT DNET GATEW. art. 1044077
  • A maximum of 50 bytes of data can get freely configured
  • Selectable modes: active heartbeat or passive polling
  • Diagnostics interface for all common networks: PROFINET IO, PROFIBUS-DP, EtherCAT, CANopen, Modbus TCP, Ethernet (TCP/IP), DeviceNet
  • XTDI input extension with eight safety inputs and eight test pulse outputs
  • XTIO input/output extension with eight safety inputs and four safety outputs (according to SIL3)
  • XTDS input/output extension with eight safety inputs, four standard outputs, two switchable outputs or test pulse outputs
FX3-ANA020002 ANALOG MODULE art. 1051134
FX3-ANA020012 ANALOG MODULE art. 1112299
  • CPU0: Basic functions incl. RS-232 programming interface
  • CPU1: CPU0 functions plus interface for advanced functions of SICK safety sensors
  • CPU2: CPU1 functions plus backup function automatic configuration recovery (ACR)
FX3-CPU320012 FX CTLR EFI LINE USB art. 1112302
FX3-EBX400002 CONNECTOR BOX art. 2068729
  • XTDI input extension with eight safety inputs and eight test pulse outputs
  • XTIO input/output extension with eight safety inputs and four safety outputs (according to SIL3)
  • XTDS input/output extension with eight safety inputs, four standard outputs, two switchable outputs or test pulse outputs
FX3-XTIO84012 FLEXISOFT 8IN/4OUT(C) art. 1050618
  • Stainless Steel enclosure
  • Installation in Zone 1, Zone 2, Zone 21 and Zone 22
  • Ex e, Ex ia and Ex tb certified
  • 21 enclosure size options
  • Return Flange Sealing
  • Customizable configuration of terminals, cable entries and cable gland types as per specification
  • Up to 4 gland plates
  • Wide range of accessories available
  • Suitable for operation in Class I, II Division 2
  • Suitable for operation in Class I Zone 2, Class II Zone 22
Terminal Box
  • Safe protection of fiber optic cable splices in hazardous areas
  • Installation in Zone 1, Zone 2, Zone 21 and Zone 22
  • Ex op pr and Ex tb certified
  • Stainless Steel enclosure
  • Up to 8 splice trays, 12 fusion-type splices per tray
  • Wide range of cable glands and stopping plugs
  • Return Flange Sealing
  • Safe protection of fiber optic cable splices in hazardous areas
  • Installation in Zone 1, Zone 2, Zone 21 and Zone 22
  • Ex op pr and Ex tb certified
  • Stainless Steel enclosure
  • 1 splice tray, 12 fusion-type splices per tray
  • Wide range of cable glands and stopping plugs
  • Return Flange Sealing
  • Safe protection of fiber optic cable splices in hazardous areas
  • Installation in Zone 1, Zone 2, Zone 21 and Zone 22
  • Ex op pr and Ex tb certified
  • Stainless Steel enclosure
  • 2 splice trays, 12 fusion-type splices per tray
  • Wide range of cable glands and stopping plugs
  • Return Flange Sealing