IEBC2,8BASKG/1,5M/PH
IEB3002BANOG/5M/PH
IEBC003BASKG/6M
IEBC003BASKG/3M
- DC
- 3-wire
- PNP
- 2 m PUR-Cable
- 2 m
- PUR
IEB21,5-ARKG/3M
Metal thread, M8 x 1, DC PNP/NPN, Cable, Sensing range 2 mm [f]
Metal thread, M8 x 1, DC PNP, Full metal housing, Increased sensing range, Gold-plated contacts, Connector, Increased sensing range, Gold-plated contacts, Sensing range 2 mm [f]
Metal thread, M8 x 1, DC PNP, Full metal housing, Increased sensing range, Gold-plated contacts, Connector, Increased sensing range, Gold-plated contacts, Sensing range 2 mm [f]
Metal thread, M8 x 1, DC NPN, Full metal housing, Increased sensing range, Gold-plated contacts, Connector, Increased sensing range, Gold-plated contacts, Sensing range 2 mm [f]
Metal thread, M8 x 1, DC NPN, Full metal housing, Increased sensing range, Gold-plated contacts, Connector, Increased sensing range, Gold-plated contacts, Sensing range 2 mm [f]
Metal thread, M8 x 1, DC PNP, Full metal housing, Increased sensing range, Gold-plated contacts, Connector, Increased sensing range, Gold-plated contacts, Sensing range 2 mm [f]
Metal thread, M8 x 1, DC PNP/NPN, Full metal housing, Increased sensing range, Cable, Increased sensing range, Sensing range 2 mm [f]
Metal thread, M8 x 1, DC PNP/NPN, Full metal housing, Increased sensing range, Cable, Increased sensing range, Sensing range 2 mm [f]
Metal thread, M8 x 1, DC PNP/NPN, Full metal housing, Increased sensing range, Gold-plated contacts, Cable with connector, Increased sensing range, Gold-plated contacts, Sensing range 2 mm [f]
- Sensing range 3 mm flush mountable
- Operating voltage 10...30 DC V
- 3-wire
- PNP
- M8 Connector
- Gold-plated contacts,Increased sensing range,Correction factor K = 1,Magnetic-field immune
- Sensing range 3 mm flush mountable
- Operating voltage 10...30 DC V
- 3-wire
- PNP
- 2 m PUR-Cable
- 2 m
- PUR
- Increased sensing range,Correction factor K = 1,Magnetic-field immune
- Sensing range 6 mm non-flush mountable
- Operating voltage 10...30 DC V
- 3-wire
- PNP
- 2 m PUR-Cable
- 2 m
- PUR
- Increased sensing range,Correction factor K = 1,Magnetic-field immune
- Sensing range 3 mm flush mountable
- Operating voltage 10...30 DC V
- 3-wire
- PNP
- 2 m PUR-Cable
- 2 m
- PUR
- Increased sensing range,Correction factor K = 1,Magnetic-field immune
- Sensing range 6 mm non-flush mountable
- Operating voltage 10...30 DC V
- 3-wire
- PNP
- 2 m PUR-Cable
- 2 m
- PUR
- Increased sensing range,Correction factor K = 1,Magnetic-field immune
- Sensing range 3 mm flush mountable
- Operating voltage 10...30 DC V
- 3-wire
- NPN
- 2 m PUR-Cable
- 2 m
- PUR
- Increased sensing range,Correction factor K = 1,Magnetic-field immune
- Sensing range 3 mm flush mountable
- Operating voltage 10...30 DC V
- 3-wire
- PNP
- M8 Connector
- Gold-plated contacts,Increased sensing range,Correction factor K = 1,Magnetic-field immune,anti-spatter
Plastic thread, M12 x 1, AC, Cable, Sensing range 2 mm [f]
Plastic thread, M12 x 1, AC, Cable, Sensing range 4 mm [nf]
Metal thread, M12 x 1, AC, Cable, Sensing range 2 mm [f]
art. 11173270
- 0 ...2 mm
- voltage output
- cable PUR, 2 m
- 10 ... 60 °C
- IP 67
art. 11173193
- 0 ... 2 mm
- voltage output
- cable PVC, 2 m
- 10 ... 60 °C
- IP 67
art. 11173266
- 0 ... 2 mm
- voltage output
- flylead connector PVC M8, L=200 mm
- 10 ... 60 °C
- IP 67
art. 11214892
- Distance measuring
- 0 ... 3 mm
- PNP / push-pull
- IO-Link
- Cable PUR, 2m
- -20 ... 70 °C
- IP 67