KB-3020-BNKG/NI/OBVZ/SN5MM
Plastic housing, ? 34 mm, DC PNP, Increased immunity to conducted radio frequency interference, Connector, Sensing range 20 mm [nf] adjustable
Capacitive sensor, Plastic housing, ? 34 mm, DC PNP, Increased immunity to conducted radio frequency interference, Connector, Sensing range 20 mm [nf] adjustable
Capacitive sensor, Plastic housing, ? 34 mm, DC NPN, Increased immunity to conducted radio frequency interference, Cable, Sensing range 20 mm [nf] adjustable 3...20 mm
  • 2-pin
  • For KC modules of K-System
  • Integrated Cold Junction Compensation
  • Packaging unit: 1 piece KC-CJC, 1 piece KC-STP-BU
  • 2-pin
  • For KC modules of K-System
  • Integrated Cold Junction Compensation
  • Packaging unit: 1 piece KC-CJC, 1 piece KC-STP-GN
  • Counter/Timer
  • Adding/subtracting via 2 separate inputs
  • Batch controller with 1 pre-selection
  • Easy-to-read, 2-line LCD display with symbols for indicated pre-selection and output status
  • Display range and preselection range from -999999 up to 999999
    Overflow will be evaluated correctly up to 1 decade
  • PNP and NPN sensors can be connected
  • Degree of protection IP65 (front only)
  • Counter/Timer
  • Adding/subtracting via 2 separate inputs
  • Batch controller with 1 pre-selection
  • Easy-to-read, 2-line LCD display with symbols for indicated pre-selection and output status
  • Display range and preselection range from -999999 up to 999999
    Overflow will be evaluated correctly up to 1 decade
  • PNP and NPN sensors can be connected
  • Degree of protection IP65 (front only)
  • Counter/Timer/TacPepperl+Fuchster
  • Adding/subtracting via 2 separate inputs
  • Batch controller with 2 pre-selections
  • Easy-to-read backlit 2-line LCD display with icons for the displayed preselection and the status of both outputs
  • Multicolor display
  • Display range and preselection range from -999999 up to 999999
    Overflow will be evaluated correctly up to 1 decade
  • PNP and NPN sensors can be connected
  • Degree of protection IP65 (front only)
  • Counter/Timer/TacPepperl+Fuchster
  • Adding/subtracting via 2 separate inputs
  • Batch controller with 2 pre-selections
  • Easy-to-read backlit 2-line LCD display with icons for the displayed preselection and the status of both outputs
  • Multicolor display
  • Display range and preselection range from -999999 up to 999999
    Overflow will be evaluated correctly up to 1 decade
  • PNP and NPN sensors can be connected
  • Degree of protection IP65 (front only)
  • Counter/Timer/TacPepperl+Fuchster
  • Adding/subtracting via 2 separate inputs
  • Batch controller with 2 pre-selections
  • Easy-to-read backlit 2-line LCD display with icons for the displayed preselection and the status of both outputs
  • Display range and preselection range from -999999 up to 999999
    Overflow will be evaluated correctly up to 1 decade
  • PNP and NPN sensors can be connected
  • Degree of protection IP65 (front only)
  • 1-channel signal conditioner
  • 24 V DC supply (loop powered)
  • Logic input 19 V DC ... 26.5 V DC, non-polarized
  • Relay contact output for de-energized to safe function
  • Test pulse immunity
  • Up to SIL 3 acc. to IEC 61508
  • Up to PL e acc. to EN/ISO 13849
  • 1-channel signal conditioner
  • 24 V DC supply (loop powered)
  • Logic input 19 V DC ... 26.5 V DC, non-polarized
  • Relay contact output for energized to safe function
  • Test pulse immunity
  • Up to SIL 3 acc. to IEC 61508
  • 1-channel isolated barrier
  • 24 V DC supply (loop powered)
  • Current limit 45 mA at 12 V DC
  • Housing width 12.5 mm
  • Connection via spring terminals with push-in connection technology
  • Up to SIL 3 acc. to IEC 61508
  • 1-channel isolated barrier
  • 24 V DC supply (loop powered)
  • Current limit 45 mA at 10 V DC
  • Test pulse immunity
  • Housing width 12.5 mm
  • Up to SIL 3 acc. to IEC 61508
  • 1-channel isolated barrier
  • 24 V DC supply (loop powered)
  • Current limit 45 mA at 12 V DC
  • Test pulse immunity
  • Housing width 12.5 mm
  • Up to SIL 3 acc. to IEC 61508
  • 1-channel isolated barrier
  • 24 V DC supply (loop powered)
  • Current limit 45 mA at 12 V DC
  • Test pulse immunity
  • Housing width 12.5 mm
  • Connection via spring terminals with push-in connection technology
  • Up to SIL 3 acc. to IEC 61508

kcd2

  • Signal transmission rate: up to 100 kbps
  • Signal transmission distance: up to 100 meters
  • Service life: up to 10 years
  • Operating temperature: -20 to +60 °C

kcd2 e2

  • Output signal: 0-20 mA, 4-20 mA, 0-10 V, 2-10 V
  • Measuring range: 0-20 mA: 4-20 mA: 0-10 В: 2-10 В
  • Accuracy: 0.5% FS
  • Response time: 10 ms
  • Operating temperature range: -25...+70 °C
  • Humidity: 95% at 40 °C

kcd2 sr

  • Overvoltage protection: up to 300 V
  • Short circuit protection: up to 20 A
  • Wire break detection: yes
  • Thermostat: yes
  • Temperature range: -20...+60 °C
  • Humidity: up to 95% without condensation

kcd2 stc

  • Rated supply current: 45 mA
  • Maximum output signal voltage: 250 V DC
  • Maximum output signal current: 20 mA
  • SmartLink support
  • HART support
  • Support for Modbus RTU
  • 1-channel terminal amplifier
  • NAMUR sensor input
  • DC 24 V supply voltage
  • Standard interface for prevention of signal transmission errors
  • Switching status indicator, yellow LED
  • Short-circuit proof electronic output
  • Low noise sensitivity
  • Compact terminal housing
  • Clips onto standard 35 mm rail to DIN EN 50 022
  • Degree of protection IP20
  • 1-channel terminal amplifier
  • NAMUR sensor input
  • DC 24 V supply voltage
  • Standard interface for prevention of signal transmission errors
  • Switching status indicator, yellow LED
  • Lead breakage monitoring: The lead breakage monitoring can be disconnected by bridging terminals 1 and 3
  • Short-circuit proof electronic output
  • Low noise sensitivity
  • Compact terminal housing
  • Clips onto standard 35 mm rail to DIN EN 50 022
  • Degree of protection IP20
  • 1-channel terminal amplifier
  • NAMUR sensor input
  • DC 24 V supply voltage
  • Standard interface for prevention of signal transmission errors
  • Switching status indicator, yellow LED
  • Short-circuit proof electronic output
  • Low noise sensitivity
  • Compact terminal housing
  • Clips onto standard 35 mm rail to DIN EN 50 022
  • Degree of protection IP20
  • 1-channel terminal amplifier
  • NAMUR sensor input
  • DC 24 V supply voltage
  • Standard interface for prevention of signal transmission errors
  • Switching status indicator, yellow LED
  • Lead breakage monitoring: The lead breakage monitoring can be disconnected by bridging terminals 1 and 3
  • Short-circuit proof electronic output
  • Low noise sensitivity
  • Compact terminal housing
  • Clips onto standard 35 mm rail to DIN EN 50 022
  • Degree of protection IP20
  • Relay output with 1 pole, yellow LED indicates switching state
  • Free-wheeling diode
  • Compact terminal housing
  • Clips onto standard 35 mm rail to DIN EN 50 022
  • Degree of protection IP20