altivar 11kw

  • Communication protocols: Modbus RTU, Profibus DP, CANopen, EtherNet/IP
  • Certificates: CE, UL, CSA, CCC

altivar 15kw

Input characteristics:

  • Rated voltage: 380-480 VAC
  • Voltage range: 300-550 V AC
  • Rated frequency: 50/60 Hz
  • Frequency range: 47-63 Hz

altivar 2.2 kw

  • Efficiency: > 95%
  • Power factor: > 0,95
  • Overload capacity: 150% for 60 seconds

altivar 22kw

  • Analog inputs: 2 current inputs (0-10 mA, -10-10 mA), 2 virtual inputs
  • Digital inputs: 6 program inputs (230 VAC/24 VDC)
  • Analog outputs: 1 current output (0-10 mA, -10-10 mA), 1 virtual output
  • Digital outputs: 2 relay outputs (250 VAC, 30 VDC)
  • Communication interfaces: RS-485, Modbus RTU, CANopen

altivar 31 0.75 kw

  • Degree of protection: IP20
  • Ambient temperature: -10°C to +40°C
  • Relative humidity: up to 90% without condensation

altivar 4kw

  • Degree of protection: IP20
  • Installation: wall mounted

altivar 5.5 kw

  • Supply voltage range: 380-460 VAC (+/- 10%)
  • Rated current: 12.5 А
  • Maximum current: 19.5 А
  • Power factor: 0.95
  • Switching frequency: 8 kHz
  • Efficiency: up to 97%.

altivar 7.5 kw

  • Nominal supply voltage: 380-500 VAC (+/- 10%)
  • Rated power supply current: 16.2 А
  • Maximum overload current: 19.8 A (60 seconds)
  • Power factor: 0.95

altivar process

  • Ambient temperature: -10°C - +40°C (standard)
  • Vibration: 0.5 g (peak-to-peak)
  • Impact: 5 g (peak-to-peak)

Pneumatic Foot Valves

univer am 5109

  • Dissipation losses: 0.35 W
  • Insulation resistance: > 100 MΩ
  • Vibration resistance: 10 G at 50-2000 Hz
  • Resistance to shocks: 50 G

univer am 5111

  • Compatibility: Compatible with other Univer Group AM series connectors and compatible with some connectors from other manufacturers.
  • Certifications: CE, UL and CSA.

univer am 5112

  • Vibration resistance: 10 G (10 Hz to 2 kHz)
  • Resistance to shocks: 50 G (0.5 ms)

univer am 5400

  • Ambient temperature: -20°C to +80°C
  • Liquid viscosity: Up to 30 cSt
  • Protection class: IP65
  • Seal material: EPDM
  • Standard: ISO 2281

univer am 5430

  • Body: aluminum alloy
  • Valve: stainless steel 304
  • Seals: NBR (butadiene nitrile rubber)
  • Spring: stainless steel 302


Pneumatic foot valve G1/4 with protecrion

Pneumatic foot valve G1/4 with protecrion

  • AMC
  • Exhaust Cleaner
  • AMC
  • Exhaust Cleaner

amg 11

  • Multiturn SSI / Profibus / CANopen® / DeviceNet / PROFINET
  • Optical sensing method
  • Singleturn 13 bit, multiturn 12 bit / 16 bit
  • EURO flange B10 / solid shaft ø11 mm
  • Multiturn sensing with microGen technologie, without gear or battery
  • Available with redundant absolute signals

AMG 11 + FSL

  • Code: Gray (SSI Version)
  • Code Sequence: CW by default
  • Inputs: SSI clock (SSI version)

amg 71

  • Measurement method: Optical
  • Code: Gray
  • Code sequence: CW
  • Inputs: SSI clock

AMG 73 S W29 S2048

  • Interface: SSI (Synchronous Serial Interface)
  • Output signal: Parallel, SSI
  • Maximum refresh rate: 10 kHz
  • Moment of inertia: 6.2 x 10^-6 kg·m²

AMG 81

  • Optical sensing method
  • Multiturn/SSI/Profibus/CANopen®
  • Singleturn 13 bit, multiturn 12 bit / 16 bit
  • EURO flange B10 / solid shaft ø11 mm

The miniature tolerance ring AN90X23 from Bosch Rexroth is a compact component designed to ensure precise and reliable positioning in pneumatic systems.

  • AN(BC Sintered)
  • Silencer
  • General Purpose
  • Metric

Size 10 (Exhaust:Circumference,Noise Reduction:21dB,Effective Area:35mm2)

muffler 1/8 pt

  • AN(BC Sintered)
  • Silencer
  • General Purpose
  • Metric

Read/write head, Cylindrical type, M12 connector

Read/write head, Cylindrical type, M18 x 1, M12 connector