Driver
Repeater
- 1-channel isolated barrier
- 24 V DC supply (loop powered)
- SMART fire alarm input
- Current input 1 mA ... 20 mA
Repeater
Repeater
- 2-channel isolated barrier
- 24 V DC supply (loop powered)
- Current input/output 4 mA ... 20 mA
- transmitter power supply
- Accuracy 0.1 %
- Reverse polarity protection
- Up to SIL 2 acc. to IEC 61508
- 2-channel isolated barrier
- 24 V DC supply (loop powered)
- Current input/output 0 mA ... 40 mA
- I/P or transmitter power supply
- Accuracy 1 %
- Up to SIL 2 acc. to IEC 61508
- 2-channel isolated barrier
- 24 V DC supply (loop powered)
- Current input/output 4 mA ... 20 mA
- Accuracy 0.1 %
- Entity parameter Io/Isc = 0 mA
- 2-channel isolated barrier
- 24 V DC supply (loop powered)
- SMART fire alarm input
- Current input 1 mA ... 20 mA
- Up to SIL 3 acc. to IEC 61508
- 16-channel
- No external power required
- HART field device input (revision 5 to 7)
- Used with HART Multiplexer Master KFD2-HMM-16
- Up to SIL3 acc. to IEC 61508
- IS K-System place holder module
- Housing width 20 mm
- Marshalling for field and control side circuits
- Configurable via plug-in jumpers
- Non-IS K-System place holder module
- Housing width 20 mm
- Marshalling for field and control side circuits
- No electrical function: empty housing
- 2-channel signal conditioner
- 24 V DC supply (loop powered)
- Logic input 15 V DC ... 30 V DC, non-polarized
- Relay contact output
- Up to SIL 3 acc. to IEC 61508
- 2-channel isolated barrier
- 24 V DC supply (loop powered)
- Logic input 15 V DC ... 30 V DC, non-polarized
- Relay contact output
- Up to SIL 3 acc. to IEC 61508
- 1-channel signal conditioner
- 24 V DC supply (loop powered)
- Logic input 20 V DC ... 30 V DC, non-polarized
- Fail-safe relay contact output
- Test pulse immunity
- Up to SIL 3 acc. to IEC 61508
- 1-channel signal conditioner
- 24 V DC supply (loop powered)
- Logic input 20 V DC ... 26.5 V DC, non-polarized
- Fail-safe relay contact output for de-energized and energized to safe function
- Test pulse immunity
- Up to SIL 3 acc. to IEC 61508
- 1-channel signal conditioner
- 24 V DC supply (loop powered)
- Current input/output 4 mA ... 20 mA
- HART I/P or transmitter power supply
- Low voltage drop
- Line fault detection (LFD)
- Up to SIL 2 acc. to IEC 61508
- 1-channel isolated barrier
- 24 V DC supply (loop powered)
- Current limit 100 mA at 10 V DC
- Up to SIL 3 acc. to IEC 61508
- 1-channel isolated barrier
- 24 V DC supply (loop powered)
- Current limit 65 mA at 9.8 V DC
- Up to SIL 3 acc. to IEC 61508
- 2-channel isolated barrier
- 24 V DC supply (loop powered)
- Current limit 45 mA at 10 V DC
- Up to SIL 3 acc. to IEC 61508
- 2-channel isolated barrier
- 24 V DC supply (loop powered)
- Current limit 45 mA at 12 V DC
- Up to SIL 3 acc. to IEC 61508
- 1-channel signal conditioner
- 24 V DC supply (loop powered)
- 2- or 3-wire Pt100 RTD input
- Output 4 mA ... 20 mA, temperature linearization selectable
- DIP switch selectable ranges
- Sensor breakage detection
- 1-channel isolated barrier
- 24 V DC supply (loop powered)
- 2- or 3-wire Pt100 RTD input
- Output 4 mA ... 20 mA, temperature linearization selectable
- DIP switch selectable ranges
- Sensor breakage detection
- 1-channel signal conditioner
- 24 V DC supply (loop powered)
- Thermocouple input
- Output 4 mA ... 20 mA
- Internal cold junction compensation
- Sensor breakage detection
- DIP switch selectable ranges
- 1-channel isolated barrier
- 24 V DC supply (loop powered)
- Thermocouple input
- Output 4 mA ... 20 mA
- Internal cold junction compensation
- Sensor breakage detection
- DIP switch selectable ranges
p&f kfd2
- Installation: KFD2 barriers can be mounted on a DIN rail or on a wall.
- Operating temperature range: -20 °C to +60 °C
- Humidity: 95% at 40 °C
- Vibration resistance: 0.3 g RMS
- Noise: <60 dBA
pepperl fuchs kfd2 sr2
- Mechanical protection: IP67
- Thermal protection: overheating protection
- Electromagnetic compatibility: meets EMC requirements
- Signal transmission rate: up to 10 Hz.
- Resource: up to 10 billion switching operations.