5 ms, 10 - 30V DC, 2 input

5 ms, 10 - 30V DC, 1 input

Micropulse level gauge

Accuracy

Rod probe: +/- 2 mm (0.08 in)
Rope probe: +/- 2 mm (0.08 in)

Process temperature

-20...+80 В°C
(-4...+176 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...6 bar,
(Vacuum...87 psi)

Max. measurement distance

Rod: 4 m (13 ft) Min DK>1.6
Rope: 12 m (40 ft) Min DK>1.6

Main wetted parts

Rod probe: 316L, PPS, Viton
Rope probe: 316, PPS, Viton

Micropulse level gauge

Micropulse level gauge

Accuracy

Rod probe :+/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft):
+/- 2 mm (0.08 in)
Rope probe > 15 m (49 ft):
+/- 10 mm (0.39 in)

Process temperature

-50...+200 В°C
(-58...+392 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...40 bar
(Vacuum...580 psi)

Max. measurement distance

Rod:
4 m (13 ft) Min DK>1.6
Rope:
25 m...30 m (82 ft...98 ft) Min DK>1.6;
30 m...45 m (98 ft...148 ft) Min DK>1,9

Main wetted parts

Rod probe:
304, 304L, 316L, PTFE, PFA
Rope probe:
304, 304L, 316, 316L, PTFE, PFA

Micropulse level gauge

Accuracy

Rod probe:+/- 2 mm (0.08 in)

Process temperature

-20...+150 В°C
(-4...+302 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...16 bar
(Vacuum...232 psi)

Max. measurement distance

Rod: 6 m (20 ft)
Min DK>1.6

Main wetted parts

Rod probe:
304, 304L, 316L, PEEK

Micropulse level gauge

Accuracy

Rod probe: +/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft):
+/- 2 mm (0.08 in)
Rope probe > 15 m (49 ft):
+/- 10 mm (0.39 in)
Coaxial probe: +/- 2 mm (0.08 in)

Process temperature

XT: -196...+280 В°C
(-321...+536 В°F)
HT: -196...+450 В°C
(-321...+842 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...400 bar
(Vacuum...5800 psi)

Max. measurement distance

Rod:
10 m (33 ft) Min DK>1.6
Rope:
25 m...30 m (82 ft...98 ft) Min DK>1.6;
30 m...45 m (98 ft...148 ft) Min DK >1,9
Coaxial probe: 6 m (20 ft) Min DK>1.4

Main wetted parts

Rod probe:
304, 316L, Alloy C, Ceramic
Rope probe:
304, 316, 316L, Alloy C, Ceramic
Coaxial probe:
304, 316L, Alloy C, Ceramic

Micropulse level gauge

Accuracy

Rod probe :
+/- 2 mm (0.08 in)
Rope probe:
+/- 2 mm (0.08 in)
Coaxial probe:
+/- 2 mm (0.08 in)

Process temperature

-40...+200 В°C
(-40...+392 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...40 bar
(Vacuum...580 psi)

Max. measurement distance

Rod: 4 m (13 ft)
Min DK >1.4
Rope: 10 m (33 ft)
Min DK >1.4
Coaxial: 6 m (20 ft)
Min DK >1.4

Main wetted parts

Rod probe:
316L, PTFE, PFA
Rope probe:
316, 316L, PTFE, PFA
Coaxial probe:
316L, PTFE, PFA

Micropulse level gauge

Accuracy

Rope probe: +/- 2 mm (0.08 in)

Process temperature

40...+120 В°C
(40...+248 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...16 bar
(Vacuum...232 psi)

Max. measurement distance

Rope: 12 m (40 ft)
Min DK >1.4

Main wetted parts

Rope probe:
304, 316, 316Ti, 316L, PEEK, PPS, PA

Micropulse level gauge

Accuracy

Rod probe: +/- 2 mm (0.08 in)
Rope probe <= 15 m (49ft):
+/- 2 mm (0.08 in)
Rope probe > 15 m (49ft):
+/- 10 mm (0,39 in)

Process temperature

-40...+150 В°C
(-40...+302 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...16 bar
(Vacuum...232 psi)

Max. measurement distance

Rod:
4 m (13 ft) Min DK>1.4
Rope:
20 m...25 m (66 ft...82 ft) Min DK >1.4;
25 m...30 m (82ft...98 ft) Min DK >1.6;
30 m...45 m (98ft...148 ft) Min DK>1,9

Main wetted parts

Rod probe:
316Ti, 316L, PEEK, PPS
Rope probe:
304, 316, 316Ti, 316L, PEEK, PPS, PA

Micropulse level gauge
Micropulse level gauge
Micropulse level gauge
Micropulse level gauge

Micropulse level gauge

Micropulse level gauge
Micropulse level gauge
Micropulse level gauge
Micropulse level gauge
Micropulse level gauge
Micropulse level gauge
TypeSWITCH ACCESSORIES
Weight0.5 kg
  • LEY
  • Electric Actuator
  • Rod Type
TypeCURRENT TRANSDUCER
Weight0.21 kg
TypeCURRENT TRANSDUCER
Weight0.15 kg
TypeCURRENT TRANSDUCE LF 305-S/SP6
Weight0.12 kg

Festo LF

Pneumatic connection, port 1G1/2
Standard nominal flow rate (standardised to DIN 1343)3000 l/min
Operating pressure0 bar - 16 bar

Festo LF

Pneumatic connection, port 1Sub-base
Operating pressure0 bar - 16 bar