• 40 mm non-flush
  • Reduction factor = 1
  • Magnetic field resistant
  • Weld Immune
  • IO-link interface for service and process data
  • Switch point mode or window mode can be set
  • Switching function, stability alarm and pulse extension can be set
  • 4-way LED indicator
  • Quick mounting bracket
Series: VariKont ®, Housing material: PA/metal with epoxy powder coating, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 4-wire, Installation: non-flush, Type of voltage: DC
Series: Cylindrical type, Housing diameter: 8 mm, Housing material: Brass, PTFE coated, Rated operating distance: 6 mm, Connection type: Connector M12 x 1 , 3-pin, Output type: 3-wire, Installation: non-flush, Type of voltage: DC
  • 6 mm non-flush
  • Reduction factor = 1
  • Magnetic field resistant
  • Stainless steel housing
Series: Rectangular type, Housing material: PBT/metal, Rated operating distance: 75 mm, Connection type: Connector M12 x 1 , 4-pin, Output type: 4-wire, Installation: non-flush, Type of voltage: DC
Series: Rectangular type, Housing material: PBT, Rated operating distance: 75 mm, Connection type: screw terminals, Output type: 4-wire, Installation: non-flush, Type of voltage: DC

Series: Rectangular type, Housing material: PBT/metal, Rated operating distance: 75 mm, Connection type: Connector M12 x 1 , 4-pin, Output type: 4-wire, Installation: non-flush, Type of voltage: DC

art. NSR 0001D

Visualisation

art. NS120701R

NS-series

art. NS127003R

NS-series

art. NS127004G

NS-series

art. NS120009M

NS12 series

art. NS050727B

NS5 series

art. NS050729R

NS5 series

Rectangular, plastics, Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW, ATEX approval, Group II, category 1D, Group II, category 1G/2G, Cable, Sensing range 2 mm [f]

IS-2002-N/OLED/0,098M/1D/1G

art. NS077001A

NS-series

art. NS077002M

NS-series

art. NS080701B

NS-series

  • No unusable area
  • 15 mm flush
  • Use of standard metallic actuating surfaces
  • Applications up to Cat. 2, PLd/SIL 2 possible (can be used redundantly up to Cat. 3, PLe/SIL 3)
  • LED for switching state and fault indication
  • Safety outputs OSSD
  • Sensor head bidirectional and rotatable
  • T??V certified
  • No unusable area
  • 2 mm flush
  • Use of standard metallic actuating surfaces
  • Applications up to Cat. 2, PLd/SIL 2 possible (can be used redundantly up to Cat. 3, PLe/SIL 3)
  • LED for switching state and fault indication
  • Safety outputs OSSD
  • T??V certified
  • E1-Type approval
  • Extended temperature range
    -40 ... +85 ?°C
  • No unusable area
  • 2 mm flush
  • Use of standard metallic actuating surfaces
  • Applications up to Cat. 2, PLd/SIL 2 possible (can be used redundantly up to Cat. 3, PLe/SIL 3)
  • LED for switching state and fault indication
  • Safety outputs OSSD
  • T??V certified
  • E1-Type approval
  • Extended temperature range
    -40 ... +85 ?°C
  • No unusable area
  • 2 mm flush
  • Use of standard metallic actuating surfaces
  • Applications up to Cat. 2, PLd/SIL 2 possible (can be used redundantly up to Cat. 3, PLe/SIL 3)
  • LED for switching state and fault indication
  • Safety outputs OSSD
  • T??V certified
  • No unusable area
  • 5 mm flush
  • Use of standard metallic actuating surfaces
  • Applications up to Cat. 2, PLd/SIL 2 possible (can be used redundantly up to Cat. 3, PLe/SIL 3)
  • LED for switching state and fault indication
  • Safety outputs OSSD
  • T??V certified
  • high-grade steel housing V4A/316L
  • No unusable area
  • 5 mm flush
  • Use of standard metallic actuating surfaces
  • Applications up to Cat. 2, PLd/SIL 2 possible (can be used redundantly up to Cat. 3, PLe/SIL 3)
  • LED for switching state and fault indication
  • Safety outputs OSSD
  • E1-Type approval
  • Extended temperature range
    -40 ... +85 ?°C
  • T??V certified