DC PNP/NPN, Analogue display 0...350° rotatable, Resolution 0.25%

with analogue display, DC PNP/NPN, Analogue display 0...350° rotatable, Resolution 0.25%, Pointer not visible when unit disconnected, Connector, analogue display, 4-digit alphanumeric display, 2 outputs, OUT1 = switching output, OUT2 = analogue output, 4-digit alphanumeric display
with analogue display, DC PNP/NPN, Analogue display 0...350° rotatable, Resolution 0.25%, Pointer not visible when unit disconnected, Connector, analogue display, 4-digit alphanumeric display, 2 outputs, OUT1 = switching output, OUT2 = analogue output, 4-digit alphanumeric display
with analogue display, DC PNP/NPN, Analogue display 0...350° rotatable, Resolution 0.25%, Pointer not visible when unit disconnected, Connector, analogue display, 4-digit alphanumeric display, 2 outputs, OUT1 = switching output, OUT2 = analogue output, 4-digit alphanumeric display
with analogue display, DC PNP/NPN, Suitable for all standard CIP and SIP processes, Analogue display 0...350° rotatable, Resolution 0.25%, Pointer not visible when unit disconnected, no dead space, Connector, analogue display, 4-digit alphanumeric display, 2 outputs, OUT1 = switching output, OUT2 = analogue output, 4-digit alphanumeric display
with analogue display, DC PNP/NPN, Suitable for all standard CIP and SIP processes, Analogue display 0...350° rotatable, Resolution 0.25%, Pointer not visible when unit disconnected, no dead space, Connector, analogue display, 4-digit alphanumeric display, 2 outputs, OUT1 = switching output, OUT2 = analogue output, 4-digit alphanumeric display

Electronic pressure sensor, with analogue display, DC PNP/NPN, Suitable for all standard CIP and SIP processes, Analogue display 0...350° rotatable, Resolution 0.25%, Pointer not visible when unit disconnected, no dead space, Connector, analogue display, 4-digit alphanumeric display, 2 outputs, OUT1 = switching output, OUT2 = analogue output, 4-digit alphanumeric display

with analogue display, DC PNP/NPN, Suitable for all standard CIP and SIP processes, Analogue display 0...350° rotatable, Resolution 0.25%, Pointer not visible when unit disconnected, no dead space, Connector, analogue display, 4-digit alphanumeric display, 2 outputs, OUT1 = switching output, OUT2 = analogue output, 4-digit alphanumeric display
with analogue display, DC PNP/NPN, Suitable for all standard CIP and SIP processes, Analogue display 0...350° rotatable, Resolution 0.25%, Pointer not visible when unit disconnected, Sealing cone G1 male, Connector, analogue display, 4-digit alphanumeric display, 2 outputs, OUT1 = switching output, OUT2 = analogue output, 4-digit alphanumeric display
with analogue display, DC PNP/NPN, Suitable for all standard CIP and SIP processes, Analogue display 0...350° rotatable, Resolution 0.25%, Pointer not visible when unit disconnected, Sealing cone G1 male, Connector, analogue display, 4-digit alphanumeric display, 2 outputs, OUT1 = switching output, OUT2 = analogue output, 4-digit alphanumeric display
with analogue display, DC PNP/NPN, Suitable for all standard CIP and SIP processes, Analogue display 0...350° rotatable, Resolution 0.25%, Pointer not visible when unit disconnected, Sealing cone G1 male, Connector, analogue display, 4-digit alphanumeric display, 2 outputs, OUT1 = switching output, OUT2 = analogue output, 4-digit alphanumeric display
with analogue display, DC PNP/NPN, Suitable for all standard CIP and SIP processes, Analogue display 0...350° rotatable, Resolution 0.25%, Pointer not visible when unit disconnected, Sealing cone G1 male, Connector, analogue display, 4-digit alphanumeric display, 2 outputs, OUT1 = switching output, OUT2 = analogue output, 4-digit alphanumeric display
with analogue display, DC PNP/NPN, Suitable for all standard CIP and SIP processes, Analogue display 0...350° rotatable, Resolution 0.25%, Pointer not visible when unit disconnected, Sealing cone G1 male, Connector, analogue display, 4-digit alphanumeric display, 2 outputs, OUT1 = switching output, OUT2 = analogue output, 4-digit alphanumeric display
  • Converts PG 9 to 1/2 inch NPT conduit
PGT-08-S PROGRAMMING TOOL art. 1036616
PGT-13-S PROGRAMMING TOOL art. 1113462
  • High chemical resistance
  • Low weight
  • Self-adhesive mounting
  • High temperature resistance
  • High mechanical stability
  • High chemical resistance
  • Low weight
  • Self-adhesive mounting
  • High temperature resistance
  • High mechanical stability
  • High chemical resistance
  • Low weight
  • High temperature resistance
  • Screw mounting for simple installation
  • Abrasion-resistant laser inscription
  • High chemical resistance
  • Low weight
  • High temperature resistance
  • Screw mounting for simple installation
  • Abrasion-resistant laser inscription
  • High chemical resistance
  • Low weight
  • Self-adhesive mounting
  • High temperature resistance
  • High mechanical stability
  • Mechanically rugged: no wearing parts, long operating life, maintenance-free
  • PROFINET interface
  • Noncontact lane tracking of a colored strip
  • Reading of Data Matrix control codes
  • Non-contact positioning on Data Matrix code tape
  • Mechanically rugged: no wearing parts, long operating life, maintenance-free
  • RS-485 interface
  • Noncontact lane tracking of a colored strip
  • Non-contact positioning on Data Matrix code tape
  • Reading of Data Matrix control codes
  • Mechanically rugged: no wearing parts, long operating life, maintenance-free
  • CANopen interface
  • Noncontact lane tracking of a colored strip
  • Noncontact positioning along the colored strip using Data Matrix codes
  • Reading of Data Matrix control codes
  • Mechanically rugged: no wearing parts, long operating life, maintenance-free
  • PROFINET interface
  • Noncontact lane tracking of a colored strip
  • Reading of Data Matrix control codes
  • Non-contact positioning on Data Matrix code tape
  • Mechanically rugged: no wearing parts, long operating life, maintenance-free
  • PROFIBUS interface
  • Noncontact lane tracking of a colored strip
  • Noncontact positioning along the colored strip using Data Matrix codes
  • Reading of Data Matrix control codes
  • Mechanically rugged: no wearing parts, long operating life, maintenance-free
  • RS-485 interface
  • Noncontact lane tracking of a colored strip
  • Noncontact positioning along the colored strip using Data Matrix codes
  • Reading of Data Matrix control codes
  • SIL 3 (EN 61508)
  • Category 4 PL e (EN ISO 13849)
  • PROFINET interface
  • PROFIsafe interface
  • Safe, non-contact positioning on Data Matrix code tape
  • Traverse distance up to 100 km
  • Mechanically rugged: no wearing parts, long operating life, maintenance-free
  • SIL 3 (EN 61508)
  • Category 4 PL e (EN ISO 13849)
  • PROFINET interface
  • PROFIsafe interface
  • Safe, non-contact positioning on Data Matrix code tape
  • Traverse distance up to 100 km
  • Mechanically rugged: no wearing parts, long operating life, maintenance-free