• Counter/Timer/TacPepperl+Fuchster with analog voltage and current output
  • Bright 6-digit LED indicator
  • AC/DC multi-range power pack
  • Counter frequency up to 25 kHz
  • Power supply for pulse generator
  • 2 separate switch inputs
  • Menu driven operation
  • Degree of protection IP64 in accordance with DIN EN 60529 (front only)
  • Including hardware for control panel mounting

Thermocouple

Accuracy

class 1 acc. to IEC 60584

Response time

depending on configuration
t50 = 6 s
t90 = 13 s

Max. process pressure (static)

at 20 В°C: 75 bar (1088 psi)

Operating temperature range

Type K:
-40 В°C ...1.100 В°C
(-40 В°F ...2.012 В°F)
Type J:
-40 В°C ...750 В°C)
(-40 В°F ...1.382 В°F)

Max. immersion length on request

up to 10.000,00 mm (393,70'')

Thermocouple

Accuracy

class 1 acc. to IEC 60584

Response time

depending on configuration
t50 = 6 s
t90 = 13 s

Max. process pressure (static)

at 20 В°C: 40 bar (580 psi)

Operating temperature range

Type K:
-40 В°C ...1.100 В°C
(-40 В°F ...2.012 В°F)
Type J:
-40 В°C ...750 В°C
(-40 В°F ...1.382 В°F)

Max. immersion length on request

up to 10.000,00 mm (393,70'')

Thermocouple

Accuracy

class 1 acc. to IEC 60584

Response time

depending on configuration
t50 = 6 s
t90 = 13 s

Max. process pressure (static)

at 20 В°C: 50 bar (725 psi)

Operating temperature range

Type K:
-40 В°C ... 1.100 В°C
(-40 В°F ...2.012 В°F)
Type J:
-40 В°C ...750 В°C
(-40 В°F ...1.382 В°F)

Max. immersion length on request

up to 10.000,00 mm (393,70'')

Thermocouple

Accuracy

class 1 acc. to IEC 60584

Response time

depending on configuration

Max. process pressure (static)

at 20 В°C: 400 bar (5.802 psi)

Operating temperature range

Type K:
-40 В°C ... 1.100 В°C
(-40 В°F ...2.012 В°F)
Type J:
-40 В°C ...750 В°C
(-40 В°F ...1.382 В°F)

Max. immersion length on request

up to 30.000,00 mm (1.181,10'')

Explosion proof thermocouple

Accuracy

class 1 acc. to IEC 60584

Response time

depending on configuration
t50 = 3 s
t90 = 7 s

Max. process pressure (static)

at 20 В°C: 100 bar (1.450 psi)

Operating temperature range

Type K:
-40 В°C ...1.100 В°C
(-40 В°F ...2.012 В°F)
Type J:
-40 В°C ...750 В°C
(-40 В°F ...1.382 В°F)

Max. immersion length on request

up to 10.000,00 mm (393,70'')

Explosion proof thermocouple

Accuracy

class 1 acc. to IEC 60584

Response time

depending on configuration
t50 = 3 s
t90 = 7 s

Max. process pressure (static)

at 20 В°C: 500 bar (7.252 psi)

Operating temperature range

Type K:
-40 В°C ...1.100 В°C
(-40 В°F ...2.012 В°F)
Type J:
-40 В°C ...750 В°C
(-40 В°F ...1.382 В°F)

Max. immersion length on request

up to 30.000,00 mm (1.181,10'')

Explosion proof thermocouple

Explosion proof thermocouple

Accuracy

class 1 acc. to IEC 60584

Response time

depending on configuration
t50 = 3 s
t90 = 7 s

Max. process pressure (static)

at 20 В°C: 80 bar (1,160 psi)

Operating temperature range

Type K:
-40 В°C ...1.100 В°C
(-40 В°F ...2.012 В°F)
Type J:
-200 В°C ...750 В°C
(-328 В°F ...1.382 В°F)

Max. immersion length on request

up to 30.000,00 mm (1.181,10'')

Explosion proof thermocouple

Accuracy

class 1 acc. to IEC 60584

Response time

depending on configuration
t50 = 3 s
t90 = 7 s

Max. process pressure (static)

at 20 В°C: 500 bar (7.252 psi)

Operating temperature range

Type K:
-40 В°C ...1.100 В°C
(-40 В°F ...2.012 В°F)
Type J:
-200 В°C ...750 В°C
(-328 В°F ...1.382 В°F)

Max. immersion length on request

up to 5.000,00 mm (196,85'')

Heating dial thermometer back bulb
Heating dial thermometer vertical bulb
TC-035CLFR12-QKPKG / US

Thermocouple

Accuracy

class 1 acc. to IEC 60584

Response time

depending on configuration
t50 = 1 s
t90 = 2 s

Max. process pressure (static)

at 20 В°C: 500 bar (7.252 psi)

Operating temperature range

Type K:
-40 В°C ...1.100 В°C
(-40 В°F ...2.012 В°F)
Type J:
-40 В°C ...750 В°C
(-40 В°F ...1.382 В°F)

Max. immersion length on request

up to 30.000,00 mm (1.181,10'')

TCC550K1ED06-A-DKG/US
TCC150K1ED06-A-DKG/US
TCC030K1ER12-A-DKG/US
TCC050K1ER12-A-DKG/US
TCC150K1ER12-A-DKG/US
  • Pluggable, mounts between device coupler and trunk cable
  • Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose
  • Optional diagnostics for wear
  • Grounding of shield via gas-discharge tube
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • Indication via LED and Advanced Diagnostics
Type of connectorRS485
RJ45
Sustainable offer statusNot Green Premium product
RoHS (date code: YYWW)Will not be Compliant