Service kit for TRM/900
Service kit for TRM/900
Service kit for TRM/900

Resistance thermometer

Accuracy

class A acc. to IEC 60751
class AA acc. to IEC 60751

Response time

depending on configuration

Max. process pressure (static)

at 20 В°C: 75 bar (1088 psi)

Operating temperature range

PT100 TF StrongSens:
-50 В°C ...500 В°C
(-58 В°F ...932 В°F)
PT100 WW:
-200 В°C ...600 В°C
(-328 В°F ...1.112 В°F)
PT100 TF:
-50 В°C ...400 В°C
(-58 В°F ...752 В°F)

Max. immersion length on request

up to 10.000,00 mm (393,70'')

Resistance thermometer

Accuracy

class A acc. to IEC 60751
class AA acc. to IEC 60751

Response time

depending on configuration

Max. process pressure (static)

at 20 В°C: 75 bar (1088 psi)

Operating temperature range

PT100 TF StrongSens:
-50 В°C ...500 В°C
(-58 В°F ...932 В°F)
PT100 WW:
-200 В°C ...600 В°C
(-328 В°F ...1.112 В°F)
PT100 TF:
-50 В°C ...400 В°C
(-58 В°F ...752 В°F)

Max. immersion length on request

up to 10.000,00 mm (393,70'')

TR110-SLU2B00 TRANSPONDER SAFETY SWITCH art. 6068077
TR110-SLUSA00 TRANSPONDER SAFETY SWITCH art. 6034589
TR110-SRU2B00 TRANSPONDER SAFETY SWITCH art. 6068076
TR110-SRU2B01 TRANSPONDER SAFETY SWITCH art. 6068078
TR110-SRUCA00 TRANSPONDER SAFETY SWITCH art. 6044635
TR110-SRUCA01 TRANSPONDER SAFETY SWITCH art. 6068075
TR110-SRUFL00 TRANSPONDER SAFETY SWITCH art. 6044632
TR110-SRUSA01 TRANSPONDER SAFETY SWITCH art. 6044631
  • Series:TR110 Lock
  • Category:Security locking devices
  • Output type: semiconductor
  • Connector type: M12
  • Connection type: connector

Resistance thermometer

Accuracy

class A acc. to IEC 60751
class AA acc. to IEC 60751

Response time

depending on configuration

Max. process pressure (static)

at 20 В°C: 40 bar (580 psi)

Operating temperature range

PT100 TF StrongSens:
-50 В°C ...500 В°C
(-58 В°F ...932 В°F)
PT100 WW:
-200 В°C ...600 В°C
(-328 В°F ...1.112 В°F)
PT100 TF:
-50 В°C ...400 В°C
(-58 В°F ...752 В°F)

Max. immersion length on request

up to 10.000,00 mm (393,70'')

Resistance thermometer

Accuracy

class A acc. to IEC 60751
class AA acc. to IEC 60751

Response time

depending on configuration

Max. process pressure (static)

at 20 В°C: 50 bar (725 psi)

Operating temperature range

PT100 TF StrongSens:
-50 В°C ...500 В°C
(-58 В°F ...932 В°F)
PT100 WW:
-200 В°C ...600 В°C
(-328 В°F ...1.112 В°F)
PT100 TF:
-50 В°C ...400 В°C
(-58 В°F ...752 В°F)

Max. immersion length on request

up to 10.000,00 mm (393,70'')

Tesistance thermometer

Accuracy

class A acc. to IEC 60751
class AA acc. to IEC 60751

Response time

depending on configuration

Max. process pressure (static)

at 20 В°C: 400 bar (5.802 psi)

Operating temperature range

PT100 TF StrongSens:
-50 В°C ...500 В°C
(-58 В°F ...932 В°F)
PT100 WW:
-200 В°C ...600 В°C
(-328 В°F ...1.112 В°F)
PT100 TF:
-50 В°C ...400 В°C
(-58 В°F ...752 В°F)

Max. immersion length on request

up to 30.000,00 mm (1.181,10'')

Resistance thermometer

Accuracy

class A acc. to IEC 60751
class AA acc. to IEC 60751

Response time

depending on configuration
t50 = 2 s
t90 = 5 s

Max. process pressure (static)

at 20 В°C: 40 bar (580 psi)

Operating temperature range

PT 100:
-200 В°C ...500 В°C
(-328 В°F ...932 В°F)

Max. immersion length on request

up to 10.000,00 mm (393,70'')

TR-000KDBM12-MFPKG/US/

Resistance thermometer

Accuracy

class A acc. to IEC 60751
class AA acc. to IEC 60751

Response time

depending on configuration
t50 = 2 s
t90 = 5 s

Max. process pressure (static)

at 20 В°C: 40 bar (580 psi)

Operating temperature range

PT 100:
-200 В°C ...600 В°C
(-328 В°F ...1.112 В°F)

Max. immersion length on request

up to 10.000,00 mm (393,70'')

TR4-RBU000 ACTUATOR art. 5321033
TR4-RFM000 ACTUATOR art. 5325633
TR4-SAM03PB TRANSPONDER SAFETY SWITCH art. 6070787
TR4-SAM10PB TRANSPONDER SAFETY SWITCH art. 6070788
TR4-SBM01CB TRANSPONDER SAFETY SWITCH art. 6070795
TR4-SBM02CB TRANSPONDER SAFETY SWITCH art. 6070801
TR4-SBU02CB TRANSPONDER SAFETY SWITCH art. 6070802
TR4-SDM03PB TRANSPONDER SAFETY SWITCH art. 6070803
  • Series:TR4 Direct
  • Category:Proximity safety switches
  • Output type: semiconductor
  • Connection type: cable
  • Case material: plastic
  • Cable length, m: 3
TR4-SDM10PB TRANSPONDER SAFETY SWITCH art. 6070804
  • Series:TR4 Direct
  • Category:Proximity safety switches
  • Output type: semiconductor
  • Connection type: cable
  • Case material: plastic
  • Cable length, m: 10
TR4-SEM02CB TRANSPONDER SAFETY SWITCH art. 6070823