UM30-213118 ULTRASONIC SENSOR art. 6036923
UM30-21311B ULTRASONIC SENSOR art. 6068449
UM30-214111 ULTRASONIC SENSOR art. 6037662
UM30-214112 ULTRASONIC SENSOR art. 6037667
UM30-214113 ULTRASONIC SENSOR art. 6036919
UM30-214118 ULTRASONIC SENSOR art. 6036924
UM30-21411B ULTRASONIC SENSOR art. 6068450
UM30-215111 ULTRASONIC SENSOR art. 6037663
UM30-215113 ULTRASONIC SENSOR art. 6036920
UM30-215114 ULTRASONIC SENSOR art. 6037678
UM30-215118 ULTRASONIC SENSOR art. 6036925

The Product is No Longer Available!

Please contact for a replacement.

  • ATEX-approval for zone 2 and zone 22
  • Front of transducer and housing manufactured entirely from stainless steel
  • Degree of protection IP68 / IP69K
  • Programmable via DTM with PACTWARE
  • Front of transducer and housing manufactured entirely from stainless steel
  • Hygienic design, easy to clean
  • Degree of protection IP68 / IP69K
  • Programmable via DTM with PACTWARE
  • Mounting bracket MH-30H-01-FA included in delivery
  • ATEX-approval for zone 2 and zone 22
  • Front of transducer and housing manufactured entirely from stainless steel
  • Degree of protection IP68 / IP69K
  • Programmable via DTM with PACTWARE
  • Front of transducer and housing manufactured entirely from stainless steel
  • Hygienic design, easy to clean
  • Degree of protection IP68 / IP69K
  • Programmable via DTM with PACTWARE
  • Mounting bracket MH-30H-01-FA included in delivery

art. 10156815

scanning range sd60 ... 400 mm
scanning range close limit Sdc60 ... 400 mm
scanning range far limit Sde60 ... 400 mm
output circuitcurrent output
operating temperature-10 ... +60 °C

art. 10151966

scanning range sd20 ... 200 mm
scanning range close limit Sdc20 ... 200 mm
scanning range far limit Sde20 ... 200 mm
output circuitcurrent output
operating temperature-10 ... +60 °C

art. 10158528

scanning range sd40 ... 400 mm
scanning range far limit Sde60 ... 400 mm
hysteresis typ.4 % Sde
output circuitNPN break function (NC)
operating temperature-10 ... +60 °C

art. 10156843

scanning range sd40 ... 400 mm
scanning range far limit Sde60 ... 400 mm
hysteresis typ.4 % Sde
output circuitPNP make function (NO)
operating temperature-10 ... +60 °C

art. 11053880

special typeHighspeed
scanning range sd10 ... 70 mm
scanning range far limit Sde30 ... 70 mm
output circuitPNP make function (NO) / break function (NC)
operating temperature-10 ... +60 °C

art. 11053882

special typeHighspeed
scanning range sd0 ... 40 mm
scanning range far limit Sde0 ... 40 mm
output circuitPNP make function (NO) / break function (NC)
operating temperature-10 ... +60 °C

art. 10156844

scanning range sd60 ... 400 mm
scanning range close limit Sdc60 ... 400 mm
scanning range far limit Sde60 ... 400 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10147642

scanning range sd20 ... 200 mm
scanning range close limit Sdc20 ... 200 mm
scanning range far limit Sde20 ... 200 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10151802

scanning range sd2 ... 82 mm
scanning range close limit Sdc2 ... 82 mm
scanning range far limit Sde2 ... 82 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10123679

scanning range sd100 ... 700 mm
scanning range far limit Sde110 ... 700 mm
hysteresis typ.4 % Sde
output circuitNPN break function (NC)
operating temperature-10 ... +60 °C

art. 10233682

scanning range sd100 ... 700 mm
scanning range far limit Sde110 ... 700 mm
hysteresis typ.4 % Sde
output circuitPNP make function (NO)
operating temperature-10 ... +60 °C
scanning range sd100 ... 700 mm
scanning range far limit Sde110 ... 700 mm
hysteresis typ.4 % Sde
output circuitPNP break function (NC)
operating temperature-10 ... +60 °C