Baumer Encoder Accessories
IN STOCK!!!
Handheld Programming Tool
- Status: LED
- Backlit display
- Menu: based intuitive programming
IN STOCK!!!
Cover
- Protective covering
- for NEMA 56C (4.5) and fan cover
- accessory for Baumer 11076547
Baumer PC Programming Tool for HS35P, EIL580P, ITD2P Programmable Encoders
Magnetic multiturn encoder
- Blind hollow shaft
- 1024 pulses per revolution
Tachometric dynamos
Magnetic detector for rotary application
Capacitance wire/wire | 67 pF/m |
Voltage | ≤ 300 V |
67 pF/m | 250...2500 |
Operating temperature | -20...+90 °C |
Baumer PC Programming Tool Z
- Ex-approved by ATEX II 2 G Ex db IIC T4/T5 Gb (gas)
- IEC Ex db IIC T4/T5 Gb (gas)
- Leakage of parasetical shaft currents
- Hollow shaft Diam.20...42 mm
9-pin, CAN, angled, with terminating resistor
- SIL3 and PLe certification
- Monitoring of underspeed, overspeed, standstill and rotating direction
- Inputs for HTL/RS422/SinCos encoders and sensors
- Safety related outputs and signal splitter
- Mounting to 35 mm DIN rail (according to EN 60715)
- USB interface for simple parametrization by the OS 6.0 operator surface
- Signal level shifting from HTL - TTL or TTL - HTL
- Isolating signal cables to multiple receivers to avoid earth loops
- Regenerating of signals when transmitting over long distance
- 1 input unit and 3 output units
- Signal level shifting from HTL - TTL or TTL - HTL
- Isolating signal cables to multiple receivers to avoid earth loops
- Regenerating of signals when transmitting over long distance
- Converting of SinCos signals into TTL and HTL signals
- Additional interpolation of the signals (multiplying or dividing)
- Oversampling with 24 MHz
- Digitally pre-filter
- Very high output frequency possible
- Converting of SinCos signals into multiplied SinCos signals
- Multiplying factor 1...128
- Offset and amplitude adjustment
- Oversampling with 24 MHz
- Digitally pre-filter
- High signal quality
- Converting of SinCos signals into multiplied SinCos signals
- Additional interpolation of HTL or TTL signals (multiplying or dividing)
- Oversampling with 24 MHz
- Digitally pre-filter
- Very high output frequency possible
Fiber-optic receiver for interference-free transmission of square-wave signals
- For high interference locations
- Each channel is coupled onto fiber-optic easy-to-fit plug
- Reconversion of optical to electrical signals in the receiver control cabinet
- 3 different plug versions available
- Delay time over a 100 m length of fiber-optic is 1 Вµs
- Except of POF all fiber optic cable usable, e. g. PCF 200 Ојm, silica fiber 50 and 62.5 Ојm
- For high interference locations
- Converting standard square-wave signals into fiber-optic signals
- Each channel is coupled onto fiber-optic easy-to-fit plug
- 3 different plug versions available
- Delay time over a 100 m length of fiber-optic is 1 Вµs
- Except of POF all fiber optic cable usable, e. g. PCF 200 Ојm, silica fiber 50 and 62.5 Ојm
- Transmission length up to 1500 m
- Reconversion of optical signals into electrical signals and generation of status signals
- Transmission error detection via checksum (CRC)
- High-precision transmission of signals (Jitter <100 ns)
- Constant delay time <20 Ојs
- Automatic channel switchover in realtime upon failure of one fiber-optic channel
- Leakage of parasetical shaft currents
- Blind hollow shaft Diam.16...30 mm
Bore Diam. 4 mm
Bore Diam. 7 mm
Bore Diam. 5 mm
Bore Diam. 6 mm
Bore Diam. 7 mm
Bore Diam. 10 mm
Bore Diam. 4 mm
Bore Diam. 6 mm