Distance sensorsOADM 12I6460/S35A with16 ... 120 mm,0 ... +50 °C,100 mA

measuring distance Sd16 ... 120 mm
adjustmentTeach-in: button / external
Teach-in range min.> 2 mm
operating temperature0 ... +50 °C
measuring distance Sd16 ... 26 mm
adjustmentTeach-in: button / external
Teach-in range min.> 1 mm
operating temperature0 ... +50 °C
measuring distance Sd50 ... 350 mm
adjustmentTeach-in: button / external
Teach-in range min.> 5 mm
operating temperature0 ... +50 °C
measuring distance Sd50 ... 550 mm
adjustmentTeach-in: button / external
Teach-in range min.> 10 mm
operating temperature0 ... +50 °C
measuring distance Sd50 ... 550 mm
adjustmentTeach-in: button / external
Teach-in range min.> 10 mm
operating temperature0 ... +50 °C
measuring distance Sd50 ... 550 mm
adjustmentTeach-in: button / external
Teach-in range min.> 10 mm
operating temperature0 ... +50 °C
measuring distance Sd100 ... 200 mm
adjustmentTeach-in: button / external
Teach-in range min.> 5 mm
operating temperature0 ... +50 °C
  • output circuit: analog
  • operating temperature: 0 ... +50 °C
  • protection class: IP 67

art. 11164061

measuring distance Sd30 ... 130 mm
adjustmentno
wave length650 nm
operating temperature0 ... +50 °C

art. 10144598

measuring distance Sd30 ... 70 mm
adjustmentTeach-in: button / external
Teach-in range min.> 2 mm
operating temperature0 ... +50 °C

art. 10144599

measuring distance Sd30 ... 130 mm
adjustmentTeach-in: button / external
Teach-in range min.> 3 mm
operating temperature0 ... +50 °C

art. 10144601

measuring distance Sd100 ... 600 mm
adjustmentTeach-in: button / external
Teach-in range min.> 10 mm
operating temperature0 ... +50 °C

art. 10144602

measuring distance Sd200 ... 1000 mm
adjustmentTeach-in: button / external
Teach-in range min.> 20 mm
operating temperature0 ... +50 °C

art. 10144603

measuring distance Sd30 ... 70 mm
adjustmentTeach-in: button / external
Teach-in range min.> 2 mm
operating temperature0 ... +50 °C

art. 11012177

measuring distance Sd200 ... 1000 mm
adjustmentTeach-in: button / external
Teach-in range min.> 20 mm
operating temperature-20 ... +60 °C

art. 11003837

measuring distance Sd200 ... 1000 mm
adjustmentTeach-in: button / external
Teach-in range min.> 10 mm
operating temperature0 ... +50 °C

art. 11017788

measuring distance Sd50 ... 300 mm
special typeWashdown design
adjustmentexternal
operating temperature0 ... +50 °C
typetolerance analysis
sensing distance Tw16 ... 120 mm
Teach-in range min.> 0,4 mm
operating temperature0 ... +50 °C
typewindow analysis
sensing distance Tw16 ... 120 mm
Teach-in range min.> 0,4 mm
operating temperature0 ... +50 °C

art. 11224111

  • art. 11224111
  • Intiutive OLED display
  • Programmable input configurations
  • Crosstalk rejection between two sensors without a wire
  • Six AUTOSET modes
  • Advanced remote programming
typemeasuring mode: edges, center, width, gap
versionPosCon 3D
measuring range (width)75 ... 125 mm
output circuitanalog and RS 485
  • Compact pressure switch 0 .. 6 bar max.40 bar
  • 1 SPDT, G1/2 male

art. 10118863

Contact Form: Double Pole, Single Throw (DPST)
Type: DC
Sensing Type: Proximity Style
Compatible Mounting Type: Surface Mount
Shield: Unshielded
Sensor Type: Solid State
Termination Type: Connector

art. 10234440

emitter / receiverreceiver
scanning range sd0 ... 700 mm
scanning range far limit Sde0 ... 700 mm
output circuitPNP complementary
operating temperature0 ... +60 °C

art. 10140060

scanning range sd10 ... 200 mm
scanning range far limit Sde30 ... 200 mm
hysteresis typ.4 % Sde
output circuitPNP make function (NO)
operating temperature-10 ... +60 °C

art. 10149127

scanning range sd100 ... 1000 mm
scanning range close limit Sdc100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10134142

scanning range sd400 ... 2500 mm
scanning range close limit Sdc400 ... 2500 mm
scanning range far limit Sde400 ... 2500 mm
output circuitcurrent output
operating temperature-10 ... +60 °C

art. 10129530

scanning range sd400 ... 2500 mm
scanning range close limit Sdc400 ... 2500 mm
scanning range far limit Sde400 ... 2500 mm
output circuitcurrent output
operating temperature-10 ... +60 °C