Festo
Choose a subcategory:
Show all categories
Festo VBNF
Festo VBNF
Festo VBOH
Valve function | 3/2 double solenoid |
Pneumatic connection, port 1 | G1/4 |
Standard nominal flow rate (standardised to DIN 1343) | 1675 l/min |
Grid dimension | 31 mm |
Festo VBOH
Valve function | 3/2 double solenoid |
Pneumatic connection, port 1 | G1/8 |
Standard nominal flow rate (standardised to DIN 1343) | 777 l/min |
Grid dimension | 24 mm |
Festo VBQF
Valve function | Quick exhaust |
Pneumatic connection, port 2 | G1/8 |
0 MPa (6->0 bar, 87->0 psi)" class="article-detail-page-header-top-feature-row-elment--HOW7D article-detail-page-header-top-feature-name--vbPt7">Standard nominal flow rate, exhaust 0.6->0 MPa (6->0 bar, 87->0 psi) | 1300 l/min |
Operating pressure | 0.5 bar - 10 bar |
Festo VBQF
Valve function | Quick exhaust |
Pneumatic connection, port 2 | G1/8 |
0 MPa (6->0 bar, 87->0 psi)" class="article-detail-page-header-top-feature-row-elment--HOW7D article-detail-page-header-top-feature-name--vbPt7">Standard nominal flow rate, exhaust 0.6->0 MPa (6->0 bar, 87->0 psi) | 1300 l/min |
Operating pressure | 0.5 bar - 10 bar |
Standard nominal flow rate (standardised to DIN 1343) | 100 l/min |
Pneumatic connection, port 1 | PK-3 |
Valve function | 3-way proportional pressure regulator |
Pneumatic connection, port 1 | QS-4 |
Electrical connection | 4-pin - M8x1 - Plugs - To EN 60947-5-2 |
Standard nominal flow rate (standardised to DIN 1343) | 5 l/min |
Valve function | 3-way proportional pressure regulator |
Pneumatic connection, port 1 | QS-4 |
Electrical connection | 4-pin - M8x1 - Plugs - To EN 60947-5-2 |
Standard nominal flow rate (standardised to DIN 1343) | 13 l/min |
Valve function | 3-way proportional pressure regulator |
Pneumatic connection, port 1 | QS-4 |
Electrical connection | 4-pin - M8x1 - Plugs - To EN 60947-5-2 |
Standard nominal flow rate (standardised to DIN 1343) | 20 l/min |
Valve function | 3-way proportional pressure regulator |
Pneumatic connection, port 1 | QS-4 |
Electrical connection | 4-pin - M8x1 - Plugs - To EN 60947-5-2 |
Standard nominal flow rate (standardised to DIN 1343) | 20 l/min |
Valve function | 2-way proportional flow control valve |
Max. current consumption | 40 mA |
Electrical connection | 4-pin - M8x1 A-encoded to EN 61076-2-104 - Plugs |
Valve function | 2-way proportional flow control valve |
Max. current consumption | 65 mA |
Electrical connection | 4-pin - M8x1 A-encoded to EN 61076-2-104 - Plugs |
Festo VFOE
Valve function | Exhaust air one-way flow control function |
Standard nominal flow rate in flow control direction | 400 l/min |
Width across flats | 16 mm |
Pneumatic connection, port 1 | QS-6 |
Festo VFOE
Valve function | Exhaust air one-way flow control function |
Standard nominal flow rate in flow control direction | 500 l/min |
Width across flats | 16 mm |
Pneumatic connection, port 1 | QS-8 |
Festo VFOE
Valve function | Exhaust air one-way flow control function |
Standard nominal flow rate in flow control direction | 720 l/min |
Width across flats | 21 mm |
Pneumatic connection, port 1 | QS-8 |
Festo VFOE
Valve function | Exhaust air one-way flow control function |
Standard nominal flow rate in flow control direction | 90 l/min |
Width across flats | 9 mm |
Pneumatic connection, port 1 | QS-4 |
Festo VFOE
Valve function | Exhaust air one-way flow control function |
Standard nominal flow rate in flow control direction | 105 l/min |
Width across flats | 9 mm |
Pneumatic connection, port 1 | QS-6 |
Festo VFOF
Valve function | Exhaust air one-way flow control function |
Standard nominal flow rate in flow control direction | 590 l/min |
Standard nominal flow rate in blocked direction | 310 l/min - 540 l/min |
Pneumatic connection, port 1 | QS-8 |
Festo VFOF
Valve function | Exhaust air one-way flow control function |
Standard nominal flow rate in flow control direction | 240 l/min |
Standard nominal flow rate in blocked direction | 120 l/min - 220 l/min |
Pneumatic connection, port 1 | QS-6 |
Valve function | 5/2 double solenoid |
Standard nominal flow rate (standardised to DIN 1343) | 750 l/min |
Pneumatic connection, port 1 | G1/8 |
Operating pressure | -0.95 bar - 10 bar |
Valve function | 3/2 double solenoid |
Standard nominal flow rate (standardised to DIN 1343) | 750 l/min |
Pneumatic connection, port 1 | G1/8 |
Operating pressure | -0.95 bar - 10 bar |
Valve function | 5/2 double solenoid |
Standard nominal flow rate (standardised to DIN 1343) | 1200 l/min |
Pneumatic connection, port 1 | G1/4 |
Operating pressure | -0.95 bar - 10 bar |
Valve function | 3/2-way, monostable, open/closed |
Standard nominal flow rate (standardised to DIN 1343) | 750 l/min |
Pneumatic connection, port 1 | G1/8 |
Operating pressure | -0.95 bar - 10 bar |
Valve function | 3/2-way, monostable, open/closed |
Standard nominal flow rate (standardised to DIN 1343) | 750 l/min |
Pneumatic connection, port 1 | G1/8 |
Operating pressure | 3.5 bar - 10 bar |
Valve function | 4/3 closed |
Standard nominal flow rate (standardised to DIN 1343) | 1500 l/min |
Pneumatic connection, port 1 | G1/4 |
pneumatic working port | G1/4 |
Valve function | 4/3 closed |
Standard nominal flow rate (standardised to DIN 1343) | 1150 l/min |
Pneumatic connection, port 1 | G1/4 |
pneumatic working port | G1/4 |
Valve function | 4/3 closed |
Standard nominal flow rate (standardised to DIN 1343) | 600 l/min |
Pneumatic connection, port 1 | G1/8 |
pneumatic working port | G1/8 |