IFM ASI modules

Active AS-i module, Mounting on DIN rail, 4 outputs, String mounting possible, Version 2.11 and 3.0 with extended addressing mode
Active AS-i module, Mounting on DIN rail, 4 inputs, String mounting possible, Version 2.11 and 3.0 with extended addressing mode
Active AS-i module, Mounting on DIN rail, 4 inputs / 4 outputs, String mounting possible, Addressing socket, Version 3.0 with extended addressing mode, Only for operation with AS-i masters with the profile M4
Active AS-i module, Mounting on DIN rail, 4 inputs / 4 outputs, String mounting possible, Addressing socket, Version 3.0 with extended addressing mode, Only for operation with AS-i masters with the profile M4

SmartL25 4DI 4DO T C

SmartL25 4DI AUX 2DO R C
SmartL25 4DI AUX 2DO R C
SmartL25 4DI 3DO T C
SmartL25 4DI AUX 3DO T C
Active ClassicLine module, AS-i flat cable connection, 4 inputs, Addressing socket, Three orientations of the flat cable are possible, ATEX approval, Group II, category 3D, Only in conjunction with impact protection housing E7000A or equivalent protection, Sockets M12 x 1
Active ClassicLine module, AS-i flat cable connection, 2 inputs / 2 outputs, Addressing socket, Three orientations of the flat cable are possible, ATEX approval, Group II, category 3D, Only in conjunction with impact protection housing E7000A or equivalent protection, Digital inputs and outputs (2 A), Sockets M12 x 1
Active ClassicLine module, AS-i flat cable connection, 4 outputs, Addressing socket, Three orientations of the flat cable are possible, ATEX approval, Group II, category 3D, Only in conjunction with impact protection housing E7000A or equivalent protection, Sockets M12 x 1
Active ClassicLine module, AS-i flat cable connection, 2 outputs / 2 inputs, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, Three orientations of the flat cable are possible, ATEX approval, Group II, category 3D, Only in conjunction with impact protection housing E7000A or equivalent protection, Sockets M12 x 1
Active ClassicLine module, AS-i flat cable connection, 4 inputs, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, Three orientations of the flat cable are possible, ATEX approval, Group II, category 3D, Only in conjunction with impact protection housing E7000A or equivalent protection, Sockets M12 x 1

ClassicLine splitter box module, AS-i flat cable connection, 4-way splitter box, Three orientations of the flat cable are possible, Sockets M12 x 1, AS-i and AUX splitter box for the connection of intelligent sensors/actuators

Active ClassicLine module, 2 outputs / 2 inputs, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, Three orientations of the flat cable are possible, Outputs supplied from AS-i, Sockets M12 x 1
Active ClassicLine module, AS-i flat cable connection, 3 outputs, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1, Digital outputs
Active ClassicLine module, AS-i flat cable connection, 4 inputs / 3 outputs, Addressing socket, Three orientations of the flat cable are possible, Version 2.11 and 3.0 with extended addressing mode, Sockets M12 x 1, Digital inputs and outputs
Active ClassicLine module, AS-i flat cable connection, 4 inputs, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1, Digital inputs
Active ClassicLine module, AS-i flat cable connection, 4 outputs, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1, Digital outputs
Active ClassicLine module, AS-i flat cable connection, 4 inputs / 4 outputs, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1, Digital inputs and outputs
Active ClassicLine module, AS-i flat cable connection, 8 digital inputs (2 slaves), Version 2.11 and 3.0 with extended addressing mode, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1, Digital inputs
Active ClassicLine module, AS-i flat cable connection, 2 inputs / 2 outputs, Addressing socket, Three orientations of the flat cable are possible, Digital inputs and outputs (2 A), Sockets M12 x 1
Active ClassicLine module, AS-i flat cable connection, 4 inputs / 4 outputs, Addressing socket, Three orientations of the flat cable are possible, Digital inputs and outputs (2 A), Sockets M12 x 1
Active ClassicLine module, AS-i flat cable connection, 4 outputs, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1, Digital outputs 2 A
Active ClassicLine module, AS-i flat cable connection, 2 outputs / 2 inputs, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1, Digital outputs and inputs
Active ClassicLine module, 2 analogue outputs 4...20 mA, Electrical isolation, Three orientations of the flat cable are possible, Sockets M12 x 1
Active ClassicLine module, AS-i flat cable connection, 2 inputs 4...20 mA, 2 analogue inputs, 4...20 mA, For the connection of 2-wire and 3-wire sensors, Addressing socket, Three orientations of the flat cable are possible
Active ClassicLine module, AS-i flat cable connection, 2 inputs 4...20 mA, 2 analogue inputs, 4...20 mA, For the connection of 2-wire and 4-wire sensors, Electrical isolation, Addressing socket, Three orientations of the flat cable are possible
Active ClassicLine module, 2 outputs / 2 inputs, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, Three orientations of the flat cable are possible, Outputs supplied from AS-i, Sockets M12 x 1, Digital outputs and inputs