IFM Electronic AS-Interface Safety at Work


502.70 EUR
AS-i safety monitor, 1 safety-related output, Basic version, 1-channel, Configuration and setup by configuration software ASIMON, Screw terminal

661.87 EUR
AS-i safety monitor, 2 safety-related outputs, Basic version, 2-channel, Configuration and setup by configuration software ASIMON, Screw terminal

564.30 EUR
AS-i safety monitor, 1 safety-related output, Extended functionality, 1-channel, Configuration and setup by configuration software ASIMON, Screw terminal

756.14 EUR

AS-Interface Monitor IFM electronic

AS-i safety monitor with 2 safety-related outputs and 2-channel. Extended functionality.


151.03 EUR

Safe AS-Interface ClassicLine module

ClassicL45 2SI 1DO M12

200.42 EUR
Safe active AS-i ClassicLine module, AS-i interface to FC/FC-E lower parts, 2 safe inputs / 2 non-safe LED outputs / 2 non-safe transistor outputs, IR addressing possible, Performance Level e, to EN ISO 13849-1 , for the connection of mechanical contacts, Sockets M12 x 1

183.81 EUR
Safe active AS-i module, 2 safe inputs (OSSD), Connection via M12x1 sockets or cage clamps, For connection of an electro-sensitive protective equipment (ESPE) type 4 to EN 61496-1

196.57 EUR

Safe AS-Interface control cabinet module

  • Safe active AS-i module
  • Operating voltage DC 26.5...31.6 V
  • DC
  • AS-i
  • terminals

206.58 EUR
Illuminated E-STOP with integrated AS-i connection, 2 safe inputs / 1 unsafe LED output, fool-proof E-STOP to EN ISO 13850, Pull to reset, AS-i interface via AS-i flat cable IP 67

212.63 EUR
Key-release E-STOP with integrated AS-i connection, 2 safe inputs, Connector M12 x 1, AS-i interface via AS-i flat cable IP 67, fool-proof E-STOP to EN ISO 13850, Reset by key operation

371.69 EUR

Safe AS-Interface E-STOP operating unit

AS-i e-stop push button box

101.86 EUR
AS-i safety PCB, 2 safe inputs / 1 unsafe LED output, Connection of mechanical contact and LED components, Certification to ISO 13849-1: PL e and IEC 61508 / SIL 3

289.30 EUR
Safe active AS-i ClassicLine module, AS-i interface to FC/FC-E lower parts, 1 safe input / 1 unsafe output, AS-i version 2.1, IR addressing possible, Control category 4 according to EN954-1, For the connection of fail-safe inductive sensors of the control category 4, Sockets M12 x 1

351.56 EUR
Safe active AS-i output module, Mounting on DIN rail, 4 non-safe inputs, 2 non-safe LED outputs, 1 safe relay output, SIL 3 to EN 62061, IEC 61508 / , SIL 3 and EN ISO 13849 - 1 / PL e, for the safe triggering of actuators, Combicon connection

588.94 EUR

AS-Interface safety monitor

  • AS-i safety monitor
  • Operating voltage DC 24 V
  • DC

784.85 EUR
AS-i safety monitor, 1 safety-related output, Extended functionality and integrated safe slave for triggering a safe AS-i output, 2-channel, Configuration and setup by configuration software ASIMON V3.0, Screw terminal

608.52 EUR
AS-i safety monitor, 2 safe semi-conductor outputs, SIL 3 to EN 62061, IEC 61508 / , SIL 3 and EN ISO 13849 - 1 / PL e, Chip card to save the configuration data, Configuration and setup by configuration software ASIMON V3 G2, USB 2.0 interface, Chip card and Combicon screw terminals supplied with the device, Screw terminal

1209.00 EUR

AS-i Profinet gateway with safe preprocessing, Housing for DIN rail mounting, 4 safe local inputs (dual channel) and 4 safe local semiconductor outputs, Ethernet configuration interface with dynamic web interface for configuration and diagnosis including remote maintenance, Profinet RT device class B, LCD colour display, Integrated safety and non safety PLC, Configuration and setup by configuration software CODESYS V3


1270.00 EUR

AS-Interface PROFIBUS DP gateway

  • AS-i PROFIBUS gateway with fail-safe PLC
  • Operating voltage DC 18...32 V
  • DC
  • PROFIBUS gateway with safe preprocessing

1209.00 EUR

AS-i EtherNet/IP gateway with safe preprocessing, Housing for DIN rail mounting, 4 safe local inputs (dual channel) and 4 safe local semiconductor outputs, Ethernet configuration interface with dynamic web interface for configuration and diagnosis including remote maintenance, LCD colour display, Integrated safety and non safety PLC, Configuration and setup by configuration software CODESYS V3


1293.00 EUR

AS-Interface EtherCAT gateway with PLC

  • AS_Interface_EtherCAT_Gateway_mit_SPS
  • Operating voltage DC 18...32 V
  • DC
  • use as AS-i EtherCAT gateway with safe preprocessing

139.15 EUR
AS-i Safety at Work, AS-i flat cable connection, 2 safe inputs / 2 non-safe LED outputs, Safe AS-i input module 2SI - 2LO, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1

183.37 EUR
AS-i Safety at Work, AS-i flat cable connection, 2x2 safe inputs / 2 non-safe LED outputs / 2 non-safe outputs, Safe AS-i input module 4SI / 2DO T / 2LO, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1

175.45 EUR
AS-i Safety at Work, AS-i flat cable connection, 2 safe inputs / 2 non-safe LED outputs / 2 non-safe outputs, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1

175.45 EUR
AS-i Safety at Work, AS-i flat cable connection, 2 safe inputs / 2 non-safe LED outputs / 2 non-safe outputs, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1