IFM Industrial communication

Choose a subcategory:
Show all categories
discontinued
IFM Electronic

AC2474

No longer produced
Find a replacement
  • PNP; (type 2 selon CEI 61131-2)
  • 20...30; (DC)
  • > 11

PCB PCI-Card 2 Master V3.0

AS-i tuner, diagnostic module, Extension of the cable to a maximum of 200 m without additional repeater, Monitoring of the message quality, Display of critical states by "traffic light" LEDs

AS-i addressing unit, AS-i version 3.0 with extended addressing mode

Power supply, AS-i dual power supply 115/230 V AC 2 x AS-i, Integrated data decoupling, AS-i switch power supplies

Power supply, AS-i power supply 115/230 V AC, Integrated data decoupling, AS-i switch power supplies

Power supply, DC convertor 24 V DC for AS-i system voltage, Integrated data decoupling, AS-i switch power supplies

SmartPLC DataLine 2ASi EIP

SmartPLC DataLine 1ASi ECAT

Active CompactLine module, AS-i flat cable connection, 60 x 152 x 27, 4 inputs / 4 outputs, IR addressing possible, Sockets M12 x 1, Digital inputs and outputs

Active CompactLine module, AS-i flat cable connection, 4 inputs / 4 outputs, IR addressing possible, Metal parts from stainless steel, Sockets M12 x 1, Digital inputs and outputs

CompactM12 4 DI-Y 4 DO V4A

Active CompactLine module, AS-i flat cable connection, 4 inputs / 4 outputs, IR addressing possible, External sensor supply PELV, Sockets M12 x 1, Digital inputs and outputs

Active ClassicLine module, AS-i interface to FC/FC-E lower parts, 4 inputs 4...20 mA, AS-i profile S-7.3, 4 analogue inputs 4...20 mA, IR addressing possible, For the connection of 2-wire, 3-wire or 4-wire sensors, Sockets M12 x 1

Active ClassicLine module, AS-i interface to FC/FC-E lower parts, 4 inputs 0...10 V, AS-i profile S-7.3, 4 analogue inputs 0...10 V, IR addressing possible, For the connection of 2-wire, 3-wire or 4-wire sensors, Sockets M12 x 1

Active ClassicLine module, AS-i interface to FC/FC-E lower parts, 4 outputs 0...20 mA, AS-i profile S-7.3, IR addressing possible, 4 analogue outputs 0...20 mA, For the connection of 2-wire actuators, Sockets M12 x 1

Active ClassicLine module, AS-i interface to FC/FC-E lower parts, 4 outputs 0...10 V, AS-i profile S-7.3, 4 analogue outputs 0...10 V, IR addressing possible, For the connection of 2-wire actuators, Sockets M12 x 1

Active ClassicLine module, AS-i interface to FC lower parts, 4 inputs Pt100, 4 analogue inputs , temperature Pt100, AS-i profile S-7.3, IR addressing possible, Sockets M12 x 1

Active ClassicLine module, AS-i interface to FC-E lower parts, 4 outputs 0...20 mA, AS-i profile S-7.3, IR addressing possible, 4 analogue outputs 0...20 mA, For the connection of 3-wire actuators, Sockets M12 x 1

Active AS-i module IP 65, AS-i interface to FC-E lower parts, 2 outputs 0...20 mA, 2 analogue outputs 0...20 mA, AS-i profile S-7.3, For the connection of 2-wire actuators or 4-wire actuators with separate 24 V supply, Connection via cage clamps

Active AS-i module IP 65, AS-i interface to FC lower parts, 4 inputs Pt100, 4 analogue inputs , temperature Pt100, AS-i profile S-7.3, Connection via cage clamps

Active ProcessLine module, 4 inputs / 3 outputs, Version 2.1 with extended addressing mode, Protection rating IP 69K, high-grade stainless steel, Sockets M12 x 1, Digital inputs and outputs


It is difficult to imagine the normal operation of a modern plant with all its production processes without reliable data transmission and transparent communication. The main goal of industrial communication is to unite all parts of the factory in a sole network frame: from the check grade to the area degree. After all, the use of all-encompassing big-efficiency information networks magnification the existence and power of both the equipment and the plant as a whole. IFM sensors and field devices can be easily integrated into existing systems, which guarantees transparent communication. and improved productivity.

Modern industrial communication also allows you to connect all business units into a single network, thereby ensuring the availability of all data and acting as the basis of the Industrial Internet of Things. In order to guarantee solid and sensible broadcast of wide amounts of data at all levels, IFM suggestions lofty-productivitysmart components.

Industrial network is a data network connecting various sensors, actuators, industrial controllers and used in industrial automation.

The main goal of industrial communication is the reliable transmission of data from the field level to the control level. Integrated solutions with the implementation of technology, modern wireless technologies and cyber protection increase the availability and security of connected systems within the web. Network records and fieldbus methods are responsible for efficient data exchange.

The starter-transducerinterface (AS-i) is a producer-irrespective rate for the hookup of drives and sensors of the early field degree. AS-Interface has get mounted as an economical installation way in technical automation.

A two-conductor tabular rope sends facts and power. This plenty decreases installation intricacy since regular parallel wiring of every sensor or transducer to the regulator is no durable necessary. It also spare the consumer a good item of terminals, dissenter boxes, inlet/outlet cards and rope lines.

AS-i sluice with combined PLC purpose control the evidence trade to the sensor/starter degree and inform fast with excellent monitoring level. They can be used as autonomous, decentralised controllers or as gateways for whole general fieldbus schemes. The row involve interfaces with EtherNet/IP, Profibus, Profinet, EtherCAT or CANopen.

The decentralised AS-Interface I/O pitches connect double and simulator sensors and drives to the gateway or PLC via AS-Interface.

Connection of the two-conductor plane rope by indicate of seclusion bias technology guarantees reverse polarity safeguard. Sensors and gears are coupled via proven, hard connectors.

IFM Industrial communication

1. Controllers

  • AS-Interface nailers
  • Industrial brainy SPS inspection lers
  • Apps

2. Pitches / Masters

  • Ethernet area mods
  • AS-Interface I/O modules
  • Fieldbus compositions

3. Schemes / Sensors
AS-Interface systems and sensors

4. Tension supply
AS-Interface energy stocks and monitors

5. Enclosures

  • AS-Interface for unsafe fields
  • AS-Interface Safety at Work