IFM Safety sensors
Choose a subcategory:
Show all categories
Safe active AS-i ClassicLine module, AS-i interface to FC/FC-E lower parts, 2 safe inputs / 2 non-safe LED outputs / 2 non-safe transistor outputs, IR addressing possible, Performance Level e, to EN ISO 13849-1 , for the connection of mechanical contacts, Sockets M12 x 1
Safe active AS-i module, 2 safe inputs (OSSD), Connection via M12x1 sockets or cage clamps, For connection of an electro-sensitive protective equipment (ESPE) type 4 to EN 61496-1
- Safe active AS-i module
- Operating voltage DC 26.5...31.6 V
- DC
- AS-i
- terminals
Illuminated E-STOP with integrated AS-i connection, 2 safe inputs / 1 unsafe LED output, fool-proof E-STOP to EN ISO 13850, Pull to reset, AS-i interface via AS-i flat cable IP 67
Key-release E-STOP with integrated AS-i connection, 2 safe inputs, Connector M12 x 1, AS-i interface via AS-i flat cable IP 67, fool-proof E-STOP to EN ISO 13850, Reset by key operation
AS-i e-stop push button box
AS-i safety PCB, 2 safe inputs / 1 unsafe LED output, Connection of mechanical contact and LED components, Certification to ISO 13849-1: PL e and IEC 61508 / SIL 3
Safe active AS-i ClassicLine module, AS-i interface to FC/FC-E lower parts, 1 safe input / 1 unsafe output, AS-i version 2.1, IR addressing possible, Control category 4 according to EN954-1, For the connection of fail-safe inductive sensors of the control category 4, Sockets M12 x 1
Safe active AS-i output module, Mounting on DIN rail, 4 non-safe inputs, 2 non-safe LED outputs, 1 safe relay output, SIL 3 to EN 62061, IEC 61508 / , SIL 3 and EN ISO 13849 - 1 / PL e, for the safe triggering of actuators, Combicon connection
AS-i Safety at Work, AS-i flat cable connection, 2 safe inputs / 2 non-safe LED outputs, Safe AS-i input module 2SI - 2LO, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1
AS-i Safety at Work, AS-i flat cable connection, 2x2 safe inputs / 2 non-safe LED outputs / 2 non-safe outputs, Safe AS-i input module 4SI / 2DO T / 2LO, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1
AS-i Safety at Work, AS-i flat cable connection, 2 safe inputs / 2 non-safe LED outputs / 2 non-safe outputs, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1
AS-i Safety at Work, AS-i flat cable connection, 2 safe inputs / 2 non-safe LED outputs / 2 non-safe outputs, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1
- AS-i Safety at Work
- Operating voltage DC 26.5...31.6 V
- DC
- M12 Connector
Safety switch with guard locking, Normally closed principle, Rotatable actuating head made of metal, Mechanical release on the front, Supply via AS-i / solenoid supply ext. from 24 V DC, M12 connector
Safety switch with guard locking, Normally open principle, Rotatable actuating head made of metal, Mechanical release on the front, Supply via AS-i / solenoid supply ext. from 24 V DC, M12 connector
Safety switch with guard locking, Normally closed principle, Rotatable actuating head made of metal, Mechanical release on the front, Supply via AS-i / solenoid supply from AS-i, M12 connector
Safety switch with guard locking, Normally open principle, Rotatable actuating head made of metal, Mechanical release on the front, Supply via AS-i / solenoid supply from AS-i, M12 connector
Connection cable , PC / AS-i safety monitor, Western connector RJ 45 8 poles / D-Sub socket 9 poles,
Connection cable , AS-i safety monitor /, AS-i safety monitor, Western connector RJ 45 8 poles,
Illuminated E-STOP,
AS-i Safety at Work, Programming software for AS-i safety monitor AC001S / AC002S / AC003S / AC004S / AC032S, Version 3.0, Configuration, set-up and diagnostics of the AS-i safety monitor
Software ASIMON V3 G2, Configuration, set-up and diagnostics of the AS-i safety monitor, AC041S
PCB 1M PANEL
USB interface cable for the connection of the safety monitor AC041S to the PC, DC,
Bolt for safety guards, For right or left hinged doors without escape release, No additional door handle required
Actuator S standard straight, With rubber bush, overtravel 5 mm, Suitable for a maximum pull force of 2500 N for the door switches AC901S - AC904S
Corner mirror, Length: 250 mm, for safety light curtains, Protected area height, 160 mm
Corner mirror, Length: 400 mm, for safety light curtains, Protected area height, 310 mm
Corner mirror, Length: 540 mm, for safety light curtains, Protected area height, 460 mm