Pepperl+Fuchs AS-Interface

AS-Interface sensor module VAA-4E-G4-ZE

  • Gateway and safety monitor in one housing

  • Connection to Ethernet Modbus TCP/IP

  • SafeLink

  • Integrated data decoupling

  • Gateway compliant with AS-Interface specification 3.0

  • Connection to PROFINET IO

  • Fault diagnosis via LEDs and grafic display

  • Easy commissioning by graphic display

  • Gateway compliant with AS-Interface specification 3.0
  • Connection to Ethernet Modbus TCP/IP
  • 2 AS-Interface networks
  • Dublicate addressing detection
  • Integrated webserver
  • Earth fault detection
  • AS-Interface noise detection
  • Ethernet diagnostic interface
  • Integrated switch allows line topology
  • DLR technology supports ring topology
  • 5 A output load
  • Wide range input 95...265 VAC
  • 24 V DC output voltage
  • Sustained short-circuit proof, overload-proof and open-circuit proof
  • LED operating display
  • LED output overload indicator
  • SELV
  • Suitable for AS-Interface power supply in gateway-integrated data decoupling
  • 8 ... 10 A output load
  • 230/115 V AC supply voltage
  • Sustained short-circuit proof, overload-proof and open-circuit proof
  • 24 ... 30 V DC output voltage, can be regulated
  • LED operating display
  • LED output overload indicator
  • SELV
  • Suitable for AS-Interface power supply in gateway-integrated data decoupling
  • 2 A output load
  • 110 - 250 VAC supply voltage
  • 24 V DC output voltage
  • Continuous short-circuit and continuous open-circuit proof
  • LED operating display
  • SELV-Output
  • Compact design
  • 89 % efficiency level
  • Suitable for AS-Interface power supply in gateway-integrated data decoupling
  • 2-channel, compelled connected
  • Outwit-proof according to ISO 13850/EN 418
  • TГњV-approval for system components is available
  • Biased actuator for self-monitoring
  • EMERGENCY STOP unlocking by turning or pulling
  • M12 plug connection
  • Small plastic housing
  • Encapsulated electronics
  • Especially suited to small doors and coverings
  • Multiple-flush magnet system
  • Cable with M12 plug
  • Small plastic housing
  • Encapsulated electronics
  • Especially suited to small doors and coverings
  • Multiple-flush magnet system
  • Cable with M12 plug
  • 2 safe inputs for mechanical contacts such as EMERGENCY-STOP switch
  • Housing with removable terminals
  • Communication monitoring
  • Power supply of inputs from the module
  • Function display for bus and inputs
  • Cross-circuit detection
  • Addressing jack
  • 2-channel, compelled connected
  • Overload-protected in accordance with IEC 60947-5-5
  • TГњV-approval for system components is available
  • Biased actuator for self-monitoring
  • EMERGENCY STOP unlocking by turning or pulling
  • Connection of contact safety switches, e.g. EMERGENCY STOP button
  • Applications up to PLe
  • Modular safety solution
  • Ultra-compact enclosure
  • Degree of protection IP67
  • Connection of contact safety switches, e.g. EMERGENCY STOP button
  • Applications up to PLe
  • Modular safety solution
  • Ultra-compact enclosure
  • Degree of protection IP67
  • Connection of contact safety switches, e.g. EMERGENCY STOP button
  • Applications up to PLe
  • Modular safety solution
  • Ultra-compact enclosure
  • Degree of protection IP67
  • Compact plastic housing
  • Encapsulated electronics
  • Especially suited to small doors and coverings
  • Multiple-flush magnet system
  • Cable with M12 plug
  • 2-channel, compelled connected
  • Overload-protected in accordance with IEC 60947-5-5
  • Integrated illumination in the actuator
  • TГњV-approval for system components is available
  • Biased actuator for self-monitoring
  • EMERGENCY STOP unlocking by turning or pulling
  • Switchable internal logic operation of the inputs and outputs via parameter bit
  • One-piece housing with stainless steel base
  • Installation without tools
  • Metal threaded inserts with SPEEDCON technology
  • Flat cable connection with cable piercing technique, variable flat cable guide
  • Red LED per channel, lights up in the event of output overload
  • Communication monitoring, configurable
  • 2 safe inputs for mechanical contacts such as EMERGENCY-STOP switch
  • DIN rail mounting
  • AS-Interface certificate
  • 2 safe inputs for mechanical contacts such as EMERGENCY-STOP switch
  • Housing with removable terminals
  • Communication monitoring
  • Power supply of outputs from the external auxiliary voltage
  • Power supply of inputs from the module
  • Function display for bus, ext. auxiliary voltage, inputs and outputs
  • Output overload monitoring
  • Switchable internal logic operation of the inputs and outputs via parameter bit
  • Addressing jack
  • Two inputs for connecting a noncontact safety device (opto-electronic safety device) PL e in accordance with EN ISO 13849-1
  • Inputs for photoelectric protective systems
  • Housing with removable terminals
  • Power supply of the inputs from the AUX auxiliary voltage
  • Power supply of outputs from auxiliary voltage AUX
  • Function display for bus, auxiliary voltage AUX, inputs and outputs
  • Up to SIL3 (EN 62061) and PLe (EN13849-1)
  • Applications up to PLd
  • 40 mm narrow construction, fixture dimensions compatible with all safety switches
  • Rotating metal head
  • Integrated guard locking up to 2500 N
  • M12 plug connection
  • Highly visible 4-way LED display
  • Applications up to PLd
  • 40 mm narrow construction, fixture dimensions compatible with all safety switches
  • Rotating metal head
  • Integrated guard locking up to 2500 N
  • M12 plug connection
  • Highly visible 4-way LED display
  • AS-Interface certificate
  • Degree of protection IP65
  • Flat or round cable connection (via standardized EMS base, not included with delivery)
  • Cable piercing method for flat cable
  • Inputs for 2- and 3-wire sensors
  • Function display for bus, inputs and outputs
  • Direct connection of pneumatic cylinders
  • AS-Interface certificate
  • Degree of protection IP67
  • Addressing jack
  • Flat cable connection with cable piercing technique, variable flat cable guide
  • Communication monitoring
  • Inputs for 2- and 3-wire sensors
  • Power supply of outputs from the external auxiliary voltage
  • Power supply of inputs from the module
  • Function display for bus, ext. auxiliary voltage, inputs and outputs
  • Monitoring of sensor overloads
  • One-piece housing with stainless steel base
  • Installation without tools
  • Metal threaded inserts with SPEEDCON technology
  • Flat cable connection with cable piercing technique, variable flat cable guide
  • Red LED per channel, lights up in the event of output overload
  • Communication monitoring, configurable
  • DIN rail mounting
  • AS-Interface certificate