Pepperl+Fuchs Terminal and Junction Boxes

  • For installation of power distribution networks
  • 316L Stainless Steel
  • Ex e certified
  • M10 internal/external brass earth stud
  • Installation in Zone 1, Zone 2, Zone 21 and Zone 22
  • 977 mm x 677 mm x 300 mm
  • Switch disconnector, 2 position with left OFF - 3x NO
  • Labeling '0 - I'
  • Auxiliary contacts - 1x NO
  • Installation in Zone 1, Zone 2, Zone 21 and Zone 22
  • Carbon loaded, antistatic glass fiber reinforced polyester
  • Bottom face cable glands polyamide, 2x M25 1x M20
  • Ex db eb and Ex tb certified
  • Padlockable switch
  • Degree of protection: IP 65
  • Switch disconnector, 2 position with left OFF - 3x NO
  • Labeling '0 - I'
  • Installation in Zone 1, Zone 2, Zone 21 and Zone 22
  • Carbon loaded, antistatic glass fiber reinforced polyester
  • Bottom face cable glands polyamide, 2x M25
  • Ex db eb and Ex tb certified
  • Padlockable switch
  • Degree of protection: IP 65
  • Switch disconnector, 2 position with left OFF - 4x NO
  • Labeling '0 - I'
  • Installation in Zone 1, Zone 2, Zone 21 and Zone 22
  • Carbon loaded, antistatic glass fiber reinforced polyester
  • Bottom face cable glands polyamide, 2x M25 1x M20
  • Ex db eb and Ex tb certified
  • Padlockable switch
  • Degree of protection: IP 65
Disconnector
  • Switch disconnector, 2 position with left OFF - 3x NO
  • Labeling '0 - I'
  • Auxiliary contacts - 1x NO
  • Installation in Zone 1, Zone 2, Zone 21 and Zone 22
  • Carbon loaded, antistatic glass fiber reinforced polyester
  • Bottom face cable glands polyamide, 2x M32 1x M20
  • Ex db eb and Ex tb certified
  • Padlockable switch
  • Degree of protection: IP 65
  • Switch disconnector, 2 position with left OFF - 4x NO
  • Labeling '0 - I'
  • Carbon loaded, antistatic glass fiber reinforced polyester
  • Installation in Zone 1, Zone 2, Zone 21 and Zone 22
  • Bottom face cable glands polyamide, 2x M32 1x M20
  • Ex db eb and Ex tb certified
  • Padlockable switch
  • Degree of protection: IP 65
  • Switch disconnector, 2 position with left OFF - 3x NO
  • Labeling '0 - I'
  • Installation in Zone 1, Zone 2, Zone 21 and Zone 22
  • Stainless Steel enclosure
  • Bottom face cable glands metal, 2x M25
  • Ex db eb and Ex tb certified
  • Padlockable switch
  • Switch disconnector, 2 position with left OFF - 3x NO
  • Labeling '0 - I'
  • Auxiliary contacts - 1x NO
  • Installation in Zone 1, Zone 2, Zone 21 and Zone 22
  • Stainless Steel enclosure
  • Bottom face cable glands metal, 2x M25 1x M20
  • Ex db eb and Ex tb certified
  • Padlockable switch
  • Degree of protection: IP 65
  • Switch disconnector, 2 position with left OFF - 4x NO
  • Labeling '0 - I'
  • Installation in Zone 1, Zone 2, Zone 21 and Zone 22
  • Stainless Steel enclosure
  • Bottom face cable glands metal, 2x M25 1x M20
  • Ex db eb and Ex tb certified
  • Padlockable switch
  • Switch disconnector, 2 position with left OFF - 3x NO
  • Labeling '0 - I'
  • Auxiliary contacts - 1x NO
  • Installation in Zone 1, Zone 2, Zone 21 and Zone 22
  • Stainless Steel enclosure
  • Bottom face cable glands metal, 2x M32 1x M20
  • Ex db eb and Ex tb certified
  • Padlockable switch
  • Degree of protection: IP 65
  • Stainless Steel enclosure
  • Various enclosure size and design variants
  • Installation in Zone 21 and Zone 22
  • Ex tD certified
  • Degree of protection IP65 / IP66
  • Customizable configuration of operators, cable entry quantities and cable gland types as per specification
  • Wide range of labels and accessories available
  • Integration of electrical components and operating elements in Ex tD enclosures as per customer specification
  • Product available for Australia and New Zealand only
  • Glass fiber reinforced polyester (GRP) enclosure
  • Installation in Zone 1, Zone 2, Zone 21 and Zone 22
  • Ex e, Ex ia and Ex tb certified
  • Modern design with high impact resistance
  • Easy installation due to easily accessible mounting points
  • Prefabricated mounting grid for flexible arrangement of internal components
  • Durable IP degree of protection due to foamed gasket and protected sealing area
  • Easy cover opening without damage due to mulitple pry points
  • Withstands temperatures down to -60 В°C
  • Customizable configuration of terminals, cable entries and cable gland types as per specification
  • Sturdy hinges as an option
  • Aluminum alloy
  • Various enclosure size and design variants
  • Ex e and Ex tD certified
  • Installation in Zone 1, Zone 2, Zone 21 and Zone 22
  • Customizable configuration as per specification
  • Degree of protection IP66
  • Stainless Steel enclosure
  • Ex d and Ex tb certified
  • Installation in Zone 1, Zone 2, Zone 21 and Zone 22
  • Gas group IIB+H2
  • Various enclosure size and design variants
  • Customizable configuration as per specification
  • Thermo-resistant tempered glass window
  • Degree of protection IP66 or IP66 / IP67