Pepperl+Fuchs
Choose a subcategory:
Show all categories
- 1-channel
- DIN rail mount module
- For intrinsically safe or non-intrinsically safe 30 V applications
- Protects field or control circuit inputs
- Max. surge current (8/20 micro-s) 20 kA
- Uninterruptable operation (auto reset)
- 2-channel
- DIN rail mount module
- For intrinsically safe or non-intrinsically safe 30 V applications
- Protects field or control circuit inputs
- Max. surge current (8/20 micro-s) 20 kA
- Uninterruptable operation (auto reset)
- 2-channel
- DIN rail mount module
- For intrinsically safe or non-intrinsically safe 30 V applications
- Protects field or control circuit inputs
- Max. surge current (8/20 micro-s) 20 kA
- Uninterruptable operation (auto reset)
- 2-channel
- DIN rail mount module
- For intrinsically safe or non-intrinsically safe 6 V applications
- Protects field or control circuit inputs
- Max. surge current (8/20 micro-s) 20 kA
- Uninterruptable operation (auto reset)
- 5 A output load
- Wide range input 95...265 VAC
- 24 V DC output voltage
- Sustained short-circuit proof, overload-proof and open-circuit proof
- LED operating display
- LED output overload indicator
- SELV
- Suitable for AS-Interface power supply in gateway-integrated data decoupling
- Suitable for the connection of sensors and absolute encoders with SSI interface
- Converts both SSI data and serial data into a parallel format
- Parallel output 25 bit (Push-pull, short-circuit proof)
- RS 232 Interface for the serial read out of sensor information
- SSI:Master or slave operation
- Specified option for arbitrary linearization characteristics
- Additional functions such as z. B. bit masking, concentricity function
- Supply 18 V DC ... 30 V DC
- Suitable for the connection of sensors and absolute encoders with SSI interface
- Analog output 0/4 mA ... 20 mA
- RS 232/RS 485-Interface for serial readout of sensor information
- SSI:Master or slave operation
- Specified option for arbitrary linearization characteristics
- Additional functions such as z. B. bit masking, concentricity function
- Supply 18 V DC ... 30 V DC
- 8 ... 10 A output load
- 230/115 V AC supply voltage
- Sustained short-circuit proof, overload-proof and open-circuit proof
- 24 ... 30 V DC output voltage, can be regulated
- LED operating display
- LED output overload indicator
- SELV
- Suitable for AS-Interface power supply in gateway-integrated data decoupling
- 2 A output load
- 110 - 250 VAC supply voltage
- 24 V DC output voltage
- Continuous short-circuit and continuous open-circuit proof
- LED operating display
- SELV-Output
- Compact design
- 89 % efficiency level
- Suitable for AS-Interface power supply in gateway-integrated data decoupling
- 2-pin
- For KC modules of K-System
- Integrated Cold Junction Compensation
- Packaging unit: 1 piece KC-CJC, 1 piece KC-STP-BU
- 2-pin
- For KC modules of K-System
- Integrated Cold Junction Compensation
- Packaging unit: 1 piece KC-CJC, 1 piece KC-STP-GN
- Counter/Timer
- Adding/subtracting via 2 separate inputs
- Batch controller with 1 pre-selection
- Easy-to-read, 2-line LCD display with symbols for indicated pre-selection and output status
- Display range and preselection range from -999999 up to 999999
Overflow will be evaluated correctly up to 1 decade - PNP and NPN sensors can be connected
- Degree of protection IP65 (front only)
- Counter/Timer
- Adding/subtracting via 2 separate inputs
- Batch controller with 1 pre-selection
- Easy-to-read, 2-line LCD display with symbols for indicated pre-selection and output status
- Display range and preselection range from -999999 up to 999999
Overflow will be evaluated correctly up to 1 decade - PNP and NPN sensors can be connected
- Degree of protection IP65 (front only)
- Counter/Timer/TacPepperl+Fuchster
- Adding/subtracting via 2 separate inputs
- Batch controller with 2 pre-selections
- Easy-to-read backlit 2-line LCD display with icons for the displayed preselection and the status of both outputs
- Multicolor display
- Display range and preselection range from -999999 up to 999999
Overflow will be evaluated correctly up to 1 decade - PNP and NPN sensors can be connected
- Degree of protection IP65 (front only)
- Counter/Timer/TacPepperl+Fuchster
- Adding/subtracting via 2 separate inputs
- Batch controller with 2 pre-selections
- Easy-to-read backlit 2-line LCD display with icons for the displayed preselection and the status of both outputs
- Multicolor display
- Display range and preselection range from -999999 up to 999999
Overflow will be evaluated correctly up to 1 decade - PNP and NPN sensors can be connected
- Degree of protection IP65 (front only)
- Counter/Timer/TacPepperl+Fuchster
- Adding/subtracting via 2 separate inputs
- Batch controller with 2 pre-selections
- Easy-to-read backlit 2-line LCD display with icons for the displayed preselection and the status of both outputs
- Display range and preselection range from -999999 up to 999999
Overflow will be evaluated correctly up to 1 decade - PNP and NPN sensors can be connected
- Degree of protection IP65 (front only)
- 1-channel signal conditioner
- 24 V DC supply (loop powered)
- Logic input 19 V DC ... 26.5 V DC, non-polarized
- Relay contact output for de-energized to safe function
- Test pulse immunity
- Up to SIL 3 acc. to IEC 61508
- Up to PL e acc. to EN/ISO 13849
- 1-channel signal conditioner
- 24 V DC supply (loop powered)
- Logic input 19 V DC ... 26.5 V DC, non-polarized
- Relay contact output for energized to safe function
- Test pulse immunity
- Up to SIL 3 acc. to IEC 61508
- 1-channel isolated barrier
- 24 V DC supply (loop powered)
- Current limit 45 mA at 12 V DC
- Housing width 12.5 mm
- Connection via spring terminals with push-in connection technology
- Up to SIL 3 acc. to IEC 61508
- 1-channel isolated barrier
- 24 V DC supply (loop powered)
- Current limit 45 mA at 10 V DC
- Test pulse immunity
- Housing width 12.5 mm
- Up to SIL 3 acc. to IEC 61508
- 1-channel isolated barrier
- 24 V DC supply (loop powered)
- Current limit 45 mA at 12 V DC
- Test pulse immunity
- Housing width 12.5 mm
- Up to SIL 3 acc. to IEC 61508
- 1-channel isolated barrier
- 24 V DC supply (loop powered)
- Current limit 45 mA at 12 V DC
- Test pulse immunity
- Housing width 12.5 mm
- Connection via spring terminals with push-in connection technology
- Up to SIL 3 acc. to IEC 61508