Schneider Electric Compact NS

Choose a subcategory:

Show all categories
Device short nameCompact NS2000N
Circuit breaker nameCompact NS2000N
Poles description4P
Neutral positionLeft
Network typeAC

Canalis KSA - power supply unit - 250A - left or right mounting

Canalis KSA - straight element 250A - 5m - 3L+N+PE - 10 windows

IN STOCK!!!

tsxcdp203

  • Length: 2 meters
  • Wire cross-section: 0.324 mm²
  • AWG gauge: AWG 22
  • Connectors: HE10
Poles description3P
Protected poles description3t
Network typeAC
Network frequency50/60 Hz
[In] rated current80 A ( 65 В°C )
Poles description3P
Protected poles description3t
Network typeAC
Network frequency50/60 Hz
[In] rated current80 A ( 65 В°C )
Poles description3P
Protected poles description3t
Network typeAC
Network frequency50/60 Hz
[In] rated current80 A ( 65 В°C )
Poles description3P
Protected poles description3t
Network typeAC
Network frequency50/60 Hz
[In] rated current80 A ( 65 В°C )
Poles description3P
Protected poles description3t
Network typeAC
Network frequency50/60 Hz
[In] rated current80 A ( 65 В°C )
Poles description3P
Protected poles description3t
Network typeAC
Network frequency50/60 Hz
[In] rated current80 A ( 65 В°C )
Poles description3P
Protected poles description3t
Network typeAC
Network frequency50/60 Hz
[In] rated current80 A ( 65 В°C )
Device short nameACP
Accessory / separate part categoryInterlocking accessory
[Us] rated supply voltage220...240 V AC 50/60 Hz
Interlocked deviceCompact NS100...630
Compact NS630b...1600
Masterpact NT
Masterpact NW
NSX100...250
NSX400...630
Selection modesCircuit breaker on N
Circuit breaker on R
Device short nameACP
Accessory / separate part categoryInterlocking accessory
[Us] rated supply voltage440 V AC 60 Hz
380...415 V AC 50/60 Hz
Interlocked deviceCompact NS100...630
Compact NS630b...1600
Masterpact NT
Masterpact NW
NSX100...250
NSX400...630
Selection modesCircuit breaker on N
Circuit breaker on R
Device short nameBA
[Us] rated supply voltage220...240 V AC 50/60 Hz
Operating modeAutomatic operation
Forced operation on normal source
Forced operation on replacement source
Stop (both normal and replacement source off)
Interlocked deviceCompact NS100...630
Compact NS630b...1600
Masterpact NT
Masterpact NW
Selection modesCircuit breaker on N
Circuit breaker on R
Device short nameBA
[Us] rated supply voltage380...415 V AC 50/60 Hz
Operating modeAutomatic operation
Forced operation on normal source
Forced operation on replacement source
Stop (both normal and replacement source off)
Interlocked deviceCompact NS100...630
Compact NS630b...1600
Masterpact NT
Masterpact NW
Selection modesCircuit breaker on N
Circuit breaker on R
Device short nameUA
[Us] rated supply voltage220...240 V AC 50/60 Hz
Operating modeAutomatic operation
Forced operation on normal source
Forced operation on replacement source
Stop (both normal and replacement source off)
Interlocked deviceCompact NS100...630
Compact NS630b...1600
Masterpact NT
Masterpact NW
Selection modesCircuit breaker on N
Circuit breaker on R
Device short nameUA
[Us] rated supply voltage380...415 V AC 50/60 Hz
Operating modeAutomatic operation
Forced operation on normal source
Forced operation on replacement source
Stop (both normal and replacement source off)
Interlocked deviceCompact NS100...630
Compact NS630b...1600
Masterpact NT
Masterpact NW
Selection modesCircuit breaker on N
Circuit breaker on R
Device short nameACP + BA
Accessory / separate part categoryInterlocking accessory
[Us] rated supply voltage220...240 V AC 50/60 Hz
Operating modeAutomatic operation
Forced operation on normal source
Forced operation on replacement source
Stop (both normal and replacement source off)
Interlocked deviceCompact NS100...630
Compact NS630b...1600
Masterpact NT
Masterpact NW
NSX100...250
NSX400...630
Device short nameACP + BA
Accessory / separate part categoryInterlocking accessory
[Us] rated supply voltage440 V AC 60 Hz
380...415 V AC 50/60 Hz
Operating modeAutomatic operation
Forced operation on normal source
Forced operation on replacement source
Stop (both normal and replacement source off)
Interlocked deviceCompact NS100...630
Compact NS630b...1600
Masterpact NT
Masterpact NW
NSX100...250
NSX400...630
Device short nameACP + UA
Accessory / separate part categoryInterlocking accessory
[Us] rated supply voltage220...240 V AC 50/60 Hz
Operating modeAutomatic operation
Forced operation on normal source
Forced operation on replacement source
Stop (both normal and replacement source off)
Interlocked deviceCompact NS100...630
Compact NS630b...1600
Masterpact NT
Masterpact NW
NSX100...250
NSX400...630
Device short nameACP + UA
Accessory / separate part categoryInterlocking accessory
[Us] rated supply voltage440 V AC 60 Hz
380...415 V AC 50/60 Hz
Operating modeAutomatic operation
Forced operation on normal source
Forced operation on replacement source
Stop (both normal and replacement source off)
Interlocked deviceCompact NS100...630
Compact NS630b...1600
Masterpact NT
Masterpact NW
NSX100...250
NSX400...630
Poles description3P
Network typeAC
Network frequency50/60 Hz
[Ie] rated operational currentAC-23A: 630 A AC 50/60 Hz 220/240 V
AC-23A: 630 A AC 50/60 Hz 380/415 V
AC-23A: 630 A AC 50/60 Hz 440/480 V
AC-23A: 630 A AC 50/60 Hz 500/525 V
AC-23A: 630 A AC 50/60 Hz 660/690 V
[Ui] rated insulation voltage800 V AC 50/60 Hz conforming to IEC 60947-3

Voltage release MN

Main contact parts set

Accessory / separate part categoryInterlocking accessory
[Us] rated supply voltage24...250 V DC
Period18 months
Device short nameIVE
Accessory / separate part categoryInterlocking accessory
[Us] rated supply voltage480 V AC 60 Hz
48...415 V AC 50/60 Hz
Period18 months
Accessory / separate part categoryInterlocking accessory
[Us] rated supply voltage24...250 V DC
Period18 months
Device short nameIVE
Accessory / separate part categoryInterlocking accessory
[Us] rated supply voltage48...415 V AC 50/60 Hz
440 V AC 60 Hz
Control typeRemote control
Period18 months
Product or component typeMechanical interlock
Accessory / separate part categoryInterlocking accessory
Poles description3P
4P
Source-changeover interlockManual
Interlocked deviceNS100...250
Device short nameIVE
Accessory / separate part categoryInterlocking accessory
[Us] rated supply voltage24...250 V DC
Control typeRemote control
Period18 months

The introduction of the Compact NS circuit breaker has revolutionized the world of molded case circuit breakers. Attractive, innovative, and of course flexible in use, the Compact NS quickly became a role model.

Equipped with new generation Micrologic monitoring and control units, modern Compact NS630b-1600 circuit breakers provide, in addition to the functions of measuring and analyzing power parameters, power measurement and electricity metering.

Compact NS Schneider Main Advantages

Unification

The circuit breakers of this series are available in one standard size, which facilitates installation and, accordingly, reduces the size of the distribution cabinet.

Efficiency

NS technology will meet all your requirements for circuit breakers from 630 to 1600 A with breaking capacity from 50 to 200 kA. Circuit breakers guarantee protection and measurement of all parameters of the electrical network, due to the equipment of electronic control and management units.

Flexibility

With the Compact NS you will always make the right choice as it meets the requirements of any application such as protection of AC installations as well as generators and motors, in turn operation in 1000 V circuits and use as a load break switch and changeover device.

Modifiability

Compact NS grows with your electrical installation: thanks to interchangeable releases and standardized accessories, the ability to change the protection calibrator without dismantling the device and the addition of signaling and control functions, Compact NS is one of the most flexible solutions on the market.

Apparatus with electrical control

The Compact NS series can be remote controlled. For this, the devices are equipped with a special electric drive for charging the spring and electromagnets for switching on and off. Remote control is usually complemented by:

  • indication of the position of the device "On / Off";
  • electrical fault indication (SDE).

Power connection

Circuit breakers can be fed from above or below without any degradation of their performance. This helps to make connections easier when installed in a switchboard.

Compact NS devices are resistant to:

  • overvoltages caused by electromagnetic disturbances;
  • overvoltages caused by atmospheric phenomena or switching of electrical networks (for example, switching off lighting);
  • radio waves of various devices (walkie-talkies, radio transmitters, etc.);
  • electrostatic discharges, the source of which is the consumers themselves.

The main series of Compact NS Schneider are:

  • compact ns100 with rated current 100 A and 3P or 4P (including ns100n, ns100h, ns100h Schneider);
  • compact ns 1600 n with Micrologic 2.0 and rated current 1600A;
  • ns160 schneider (ns 160 n) – 2 poles switch disconnector with 160A;
  • compact ns400 is 3 poles and 400A disconnector (including ns400n and ns400h Schneider);
  • compact ns 800 (with ns800n micrologic 2.0, ns800h, ns800n 3p and ns800n 4p, mccb ns800n).

Now Compact NS series is discontinued by Schneider Electric. You can get a replacement by contacting our managers.  We will offer you full range of Schneider Compact  with a favorable price and with the best delivery times.