Schneider Electric Compact NSX Accessories

Range compatibilityCompact NSX630
Compact NSX400
Device applicationDistribution
Generator
Poles description3P
Protected poles description3t
Network typeAC
Range compatibilityCompact NSX630
Compact NSX400
Device applicationDistribution
Generator
Poles description4P
Protected poles description3t
3t + 1.6 N
3t + N/2
4t
Neutral positionLeft
Product or component typeCase
Accessory / separate part categoryMaintenance accessory
Provided equipmentPower supply
USB maintenance interface
USB cord
RJ45/RJ45 male cord
Microligic cord
Sustainable offer statusNot Green Premium product
RoHS (date code: YYWW)Will not be Compliant
Circuit breaker nameCompact NS100L
Poles description3P
Network typeAC
DC
Network frequency50/60 Hz
Control typeToggle
Device short nameMN with time delay
Voltage release typeUndervoltage release
Control circuit voltage220...240 V AC 50/60 Hz
Threshold tripping voltage0.85 Un - during closing time
0.35...0.7 Un - during opening time
Supply holding power< 5 VA
Device short nameMN delay unit
Voltage release typeInstantaneous
Control circuit voltage48...60 V DC
48...60 V AC 50/60 Hz
Impulse duration200 ms
Time delay range0.5...3 s
Accessory / separate part typeTrip unit accessories
Trip unit nameSTR
Period18 months
Accessory / separate part typeTrip unit accessories
Trip unit nameSTR
Period18 months
Accessory / separate part typeWiring accessory
Location of connectionInside
Localisation on deviceInterface module
Length60 m
Product compatibilityPowerPact H-Frame
PowerPact J-Frame
PowerPact L-Frame
Accessory / separate part typeControl units accessories
[Us] rated supply voltage24...30 V - DC - tolerance: +/- 20 %
Product compatibilityPowerPact H-Frame
PowerPact J-Frame
PowerPact L-Frame
Trip unit nameMicrologic
Overvoltage categoryIV
Accessory / separate part typeControl units accessories
[Us] rated supply voltage48...60 V - DC - tolerance: +/- 20 %
Product compatibilityPowerPact H-Frame
PowerPact J-Frame
PowerPact L-Frame
Trip unit nameMicrologic
Overvoltage categoryIV
Accessory / separate part typeControl units accessories
[Us] rated supply voltage100...125 V - DC - tolerance: +/- 20 %
Product compatibilityPowerPact H-Frame
PowerPact J-Frame
PowerPact L-Frame
Trip unit nameMicrologic
Overvoltage categoryIV
Accessory / separate part typeControl units accessories
[Us] rated supply voltage110...130 V - AC - 50/60 Hz tolerance: +10 % -15 %
Product compatibilityPowerPact H-Frame
PowerPact J-Frame
PowerPact L-Frame
Trip unit nameMicrologic
Overvoltage categoryIV
Accessory / separate part typeControl units accessories
[Us] rated supply voltage200...240 V - AC - 50/60 Hz tolerance: +10 % -15 %
Product compatibilityPowerPact H-Frame
PowerPact J-Frame
PowerPact L-Frame
Trip unit nameMicrologic
Overvoltage categoryIV
Accessory / separate part typeControl units accessories
[Us] rated supply voltage380...415 V - AC - 50/60 Hz tolerance: +10 % -15 %
Product compatibilityPowerPact H-Frame
PowerPact J-Frame
PowerPact L-Frame
Trip unit nameMicrologic
Overvoltage categoryIV
Device short nameBattery
Accessory / separate part typeElectrical accessories
Mounting modeFixed
[Ue] rated operational voltage24 V DC
Range compatibilityCompact NSX250
Compact NSX160
Compact NSX100
Device applicationDistribution
Poles description4P
Protected poles description4t
Neutral positionLeft
Range compatibilityCompact NSX250
Compact NSX160
Compact NSX100
Device applicationDistribution
Poles description4P
Protected poles description4t
Neutral positionLeft
Range compatibilityCompact NSX250
Compact NSX160
Compact NSX100
Device applicationDistribution
Poles description3P
Protected poles description3t
Network typeAC
Range compatibilityCompact NSX250
Compact NSX160
Compact NSX100
Device applicationDistribution
Poles description3P
Protected poles description3t
Network typeAC
Range compatibilityCompact NSX250
Compact NSX160
Compact NSX100
Device applicationGenerator
Poles description3P
Protected poles description3t
Network typeAC
Range compatibilityCompact NSX250
Compact NSX160
Compact NSX100
Device applicationGenerator
Poles description3P
Protected poles description3t
Network typeAC
Range compatibilityCompact NSX250
Compact NSX160
Compact NSX100
Device applicationDistribution
Poles description4P
Protected poles description3t
3t + N/2
4t
Neutral positionLeft
Range compatibilityCompact NSX250
Compact NSX160
Compact NSX100
Device applicationDistribution
Poles description4P
Protected poles description3t
3t + N/2
4t
Neutral positionLeft
Range compatibilityCompact NSX250
Compact NSX160
Compact NSX100
Device applicationGenerator
Poles description4P
Protected poles description3t
3t + N/2
4t
Neutral positionLeft
Range compatibilityCompact NSX250
Compact NSX160
Compact NSX100
Device applicationGenerator
Poles description4P
Protected poles description3t
3t + N/2
4t
Neutral positionLeft
Range compatibilityCompact NSX250
Compact NSX160
Compact NSX100
Device applicationDistribution
Generator
Poles description3P
Protected poles description3t
Network typeAC
Range compatibilityCompact NSX250
Compact NSX160
Compact NSX100
Device applicationDistribution
Generator
Poles description3P
Protected poles description3t
Network typeAC
Range compatibilityCompact NSX250
Compact NSX160
Compact NSX100
Device applicationDistribution
Generator
Poles description3P
Protected poles description3t
Network typeAC
Range compatibilityCompact NSX250
Compact NSX160
Compact NSX100
Device applicationDistribution
Generator
Poles description3P
Protected poles description3t
Network typeAC

in international format without spaces