nsx100n tm100d

  • Rated operating frequency: 50/60 Hz
  • Maximum operating voltage: 440 V AC
  • Insulation limit voltage: 690 V AC
  • Mechanical wear resistance: 10,000 on/off cycles
  • Electrical wear resistance: 2000 on/off cycles at short-circuit current

nsx100n tm63d

  • Rated operating voltage (Ue): 690 V AC 50/60 Hz
  • Maximum operating voltage (Umax): 720 V AC 50/60 Hz
  • Rated operating frequency: 50/60 Hz
  • Maximum power loss: 10 W

25 kA at 415 VAC, 3 poles 3d, TMD trip unit 125 A

25 kA (415 VAC), ComPact NSX160B, TMD trip unit 160 A, 3 poles, 3d

nsx160f 125a

Rated operating frequency: 50/60 Hz
Current control limit of the thermal disconnector: 0.5 - 1.25 In
Current control limit of the electromagnetic release: 3 - 12 In

nsx160f 160a

  • Rated operating frequency: DC
  • Heating limit: 85°C
  • Electrical wear resistance: CO, CE
  • Operating temperature range: -25°C to +70°C
  • Storage temperature: -40°C to +80°C

nsx160f ma150

  • Short circuit current limit (Icu): 36 kA
  • Operating frequency: 50/60 Hz
  • Maximum switching voltage: 690 В
  • Mechanical resistance: 12 mechanical on/off cycles

schneider electric nsx250b

  • Operating temperature range: From -25°C to +55°C
  • Vibration resistance: Meets the requirements of IEC 60068-2-6
  • Impact resistance: Meets the requirements of IEC 60068-2-7

nsx250b micrologic 2.2

  • Mounting: DIN rail or panel
  • Vibration resistance: 3g/10 Hz
  • Impact resistance: 50g/11ms

nsx250b tm250d

  • Operating temperature range: -25°C...+70°C
  • Vibration resistance: according to IEC 60068-2-6
  • Impact resistance: according to IEC 60068-2-7
  • Electrical resistance: according to IEC 60947-2

nsx250f

  • Maximum operating voltage: 253/440 V AC
  • Nominal DC voltage: 750 V
  • Maximum DC voltage: 825 V
  • Voltage drop: 0.75% (at rated current)
  • Power consumption: 7.5 VA (AC) / 12 VA (DC)

nsx250f tm200d

  • Frequency: 50/60 Hz
  • Maximum overload current: 1.31 x In (1 x hour)
  • Short-time withstand current: 1.45 x In (0.5 s)
  • Thermal Uncoupling Limit: 1.1 x In

nsx250f tm250d

  • Maximum switching capacity: 250 A
  • Mechanical wear resistance: 10,000 on/off cycles
  • Electrical durability: 2,000 on/off cycles under load

nsx250n 3p

  • Operating switching power: 52 kW
  • Maximum switching power: 104 kW
  • Switching power limit: 156 kW
  • Maximum switching power: 208 kW

nsx250n 4p

  • Rated short-circuit current (Ics): 10 kA
  • Thermal current limit (Ith): 300 A
  • Nominal power loss: 12.5 W
  • Electrical wear resistance: CO-EI

nsx250n ma220

  • Degree of protection: IP40
  • Impact resistance: IK07
  • Mounting: DIN rail or panel

nsx250n micrologic 2.2

  • Nominal operating frequency: 50/60 Hz
  • Nominal power: up to 175 kW
  • Electromagnetic compatibility: conforms to IEC 61134-2 and IEC 61000-6-1
  • Short-circuit withstand current: 50 kA at 220/240 V AC 50/60 Hz
  • Limiting current characteristic: Icu = 90 kA at 220/240 V AC 50/60 Hz

nsx250n tm250d

  • Rated voltage: 400 V AC
  • Frequency: 50 Hz
  • Short circuit current limit: 12 kA
  • Peak short-circuit current: 36 kA
  • Operating frequency: 0.5 Hz
  • Electrical wear resistance: CO 10,000

nsx400f micrologic 2.3

  • Ambient temperature: from -25°C to +55°C
  • Mounting: on a DIN rail or panel
  • Connection: cable clamps, terminals

nsx400h micrologic 2.3

  • Nominal operating frequency: 50/60 Hz
  • Thermal current limit: 0.4 - 1.0 In
  • Short-term withstand current: 12 In for 1 s
  • Peak Current: 14 In

nsx400n micrologic 2.3

  • Nominal operating frequency: 50/60 Hz
  • Heat release limit: 60°C

nsx630a

  • Limit of mechanical resistance: up to 10 kA
  • Thermal resistance limit: up to 630 A
  • Limit of dynamic stability: up to 63 kA

nsx630n 4p

  • Rated voltage: 415 V AC
  • Frequency: 50/60 Hz
  • Maximum power loss: 30 W
  • Mechanical wear resistance: 10,000 on/off cycles
  • Electrical durability: 20,000 on/off cycles
  • Switching capacity: category AC-3E


nsx630n micrologic 2.3

  • Degree of protection: IP40
  • Operating temperature range: from -25°C to +55°C
  • Body material: thermoplastic
  • Installation: on a DIN rail
  • phase control relay 

  • 2OF 

  • 208 to 480Vac

ComPact NS1250N - circuit breaker - 4P4D - 50KA - Micrologic 2.0E - fixed front terminal

  • ComPacT NSX250F - circuit breaker 
  • TM-D 250A 
  • 4P3D
  • 36kA 
  • fixed mounting
  • ComPacT NSX400F - circuit breaker 
  • MicroLogic 2.3
  • 400A 
  • 4P4D 
  • 36kA - fixed
  • MicroLogic 5.3 E
  • 630A - 4P4D trip unit for NSX630