Schneider Electric
Choose a subcategory:
Show all categories
| Device short name | BA |
| [Us] rated supply voltage | 220...240 V AC 50/60 Hz |
| Operating mode | Automatic operation Forced operation on normal source Forced operation on replacement source Stop (both normal and replacement source off) |
| Interlocked device | Compact NS100...630 Compact NS630b...1600 Masterpact NT Masterpact NW |
| Selection modes | Circuit breaker on N Circuit breaker on R |
| Device short name | BA |
| [Us] rated supply voltage | 380...415 V AC 50/60 Hz |
| Operating mode | Automatic operation Forced operation on normal source Forced operation on replacement source Stop (both normal and replacement source off) |
| Interlocked device | Compact NS100...630 Compact NS630b...1600 Masterpact NT Masterpact NW |
| Selection modes | Circuit breaker on N Circuit breaker on R |
| Device short name | UA |
| [Us] rated supply voltage | 220...240 V AC 50/60 Hz |
| Operating mode | Automatic operation Forced operation on normal source Forced operation on replacement source Stop (both normal and replacement source off) |
| Interlocked device | Compact NS100...630 Compact NS630b...1600 Masterpact NT Masterpact NW |
| Selection modes | Circuit breaker on N Circuit breaker on R |
| Device short name | UA |
| [Us] rated supply voltage | 380...415 V AC 50/60 Hz |
| Operating mode | Automatic operation Forced operation on normal source Forced operation on replacement source Stop (both normal and replacement source off) |
| Interlocked device | Compact NS100...630 Compact NS630b...1600 Masterpact NT Masterpact NW |
| Selection modes | Circuit breaker on N Circuit breaker on R |
| Device short name | ACP + BA |
| Accessory / separate part category | Interlocking accessory |
| [Us] rated supply voltage | 220...240 V AC 50/60 Hz |
| Operating mode | Automatic operation Forced operation on normal source Forced operation on replacement source Stop (both normal and replacement source off) |
| Interlocked device | Compact NS100...630 Compact NS630b...1600 Masterpact NT Masterpact NW NSX100...250 NSX400...630 |
| Device short name | ACP + BA |
| Accessory / separate part category | Interlocking accessory |
| [Us] rated supply voltage | 440 V AC 60 Hz 380...415 V AC 50/60 Hz |
| Operating mode | Automatic operation Forced operation on normal source Forced operation on replacement source Stop (both normal and replacement source off) |
| Interlocked device | Compact NS100...630 Compact NS630b...1600 Masterpact NT Masterpact NW NSX100...250 NSX400...630 |
| Device short name | ACP + UA |
| Accessory / separate part category | Interlocking accessory |
| [Us] rated supply voltage | 220...240 V AC 50/60 Hz |
| Operating mode | Automatic operation Forced operation on normal source Forced operation on replacement source Stop (both normal and replacement source off) |
| Interlocked device | Compact NS100...630 Compact NS630b...1600 Masterpact NT Masterpact NW NSX100...250 NSX400...630 |
| Device short name | ACP + UA |
| Accessory / separate part category | Interlocking accessory |
| [Us] rated supply voltage | 440 V AC 60 Hz 380...415 V AC 50/60 Hz |
| Operating mode | Automatic operation Forced operation on normal source Forced operation on replacement source Stop (both normal and replacement source off) |
| Interlocked device | Compact NS100...630 Compact NS630b...1600 Masterpact NT Masterpact NW NSX100...250 NSX400...630 |
| Poles description | 3P |
| Network type | AC |
| Network frequency | 50/60 Hz |
| [Ie] rated operational current | AC-23A: 630 A AC 50/60 Hz 220/240 V AC-23A: 630 A AC 50/60 Hz 380/415 V AC-23A: 630 A AC 50/60 Hz 440/480 V AC-23A: 630 A AC 50/60 Hz 500/525 V AC-23A: 630 A AC 50/60 Hz 660/690 V |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz conforming to IEC 60947-3 |
Masterpact NW32HA
55 kw soft starter schneider
- Operating temperature range: -10°C to +50°C
- Degree of protection: IP20
- Type of terminals: Screw
- Cable cross-section: 25 mm²
7.5 kw soft starter schneider
- Maximum switching current: 34 А
- Power factor: 0.95
- Operating temperature range: -10°C to +50°C
- Storage range: -25°C to +70°C
- Insulation class: F
- Acti9 iC60L
- 2P, 16 A
- C curve
- 15000 A (IEC 60898-1)
- 25 kA (IEC 60947-2)
- rated current: 40 A
- Network Frequency: 50/60 Hz
- Weight: 0.37 kg
- Mechanical durability: 20,000 cycles
Dedicated output module for PLC signals
Electromechanical switching and solid state switching
LED indication for control signal state
High performance ensuring machine and system availability
Easy to use
| Product or component type | Room temperature controller |
| Device presentation | Insert with central cover plate |
| Bus type | KNX |
| Colour tint | Polar white matt (RAL 9003) |
| Display type | Digital display |
altistart 3
- Operating temperature range: -20°C to +50°C
- Degree of protection: IP20
- Mounting: on a panel or on a DIN rail
altivar 0.75 kw
- Installation: wall mounted
- Body: ABS plastic
- Radiator: aluminum
- Certificates: CE, CSA, UL
altivar 1.5 kw
- Ambient temperature: -10°C to +40°C
- Installation: Wall mounted
altivar 11kw
- Communication protocols: Modbus RTU, Profibus DP, CANopen, EtherNet/IP
- Certificates: CE, UL, CSA, CCC
altivar 15kw
Input characteristics:
- Rated voltage: 380-480 VAC
- Voltage range: 300-550 V AC
- Rated frequency: 50/60 Hz
- Frequency range: 47-63 Hz
altivar 2.2 kw
- Efficiency: > 95%
- Power factor: > 0,95
- Overload capacity: 150% for 60 seconds
altivar 22kw
- Analog inputs: 2 current inputs (0-10 mA, -10-10 mA), 2 virtual inputs
- Digital inputs: 6 program inputs (230 VAC/24 VDC)
- Analog outputs: 1 current output (0-10 mA, -10-10 mA), 1 virtual output
- Digital outputs: 2 relay outputs (250 VAC, 30 VDC)
- Communication interfaces: RS-485, Modbus RTU, CANopen
altivar 31 0.75 kw
- Degree of protection: IP20
- Ambient temperature: -10°C to +40°C
- Relative humidity: up to 90% without condensation
altivar 4kw
- Degree of protection: IP20
- Installation: wall mounted
altivar 5.5 kw
- Supply voltage range: 380-460 VAC (+/- 10%)
- Rated current: 12.5 А
- Maximum current: 19.5 А
- Power factor: 0.95
- Switching frequency: 8 kHz
- Efficiency: up to 97%.
altivar 7.5 kw
- Nominal supply voltage: 380-500 VAC (+/- 10%)
- Rated power supply current: 16.2 А
- Maximum overload current: 19.8 A (60 seconds)
- Power factor: 0.95
altivar process
- Ambient temperature: -10°C - +40°C (standard)
- Vibration: 0.5 g (peak-to-peak)
- Impact: 5 g (peak-to-peak)
schneider ats01n2
Rated frequency: 50/60 Hz
Efficiency: > 95%
Power factor: > 0,95
Current consumption: < 1 А
Type of control: Thyristor