Siemens Process instrumentation

Choose a subcategory:

Show all categories

SIPART DR22 CONTROLLER &quot,&quot,NEW&quot,&quot, FOR AC/DC 24 V POWER SUPPLY STANDARD CONTROLLER WITH - 3 ANALOG INPUTS 0/4 TO 20 MA OR 0/2-10V - 3 ANALOG OUTPUTS 0/4 TO 20 MA - 4 DIGITAL INPUTS DC 24 V - 8 DIGITAL OUTPUTS DC 24 V

SIPART DR22 CONTROLLER &quot,&quot,NEW&quot,&quot, FOR AC 230/115V POWER SUPPLY STANDARD CONTROLLER WITH - 3 ANALOG INPUTS 0/4 TO 20 MA OR 0/2-10 V - 3 ANALOG OUTPUTS 0/4 TO 20 MA - 4 DIGITAL INPUTS DC 24 V - 8 DIGITAL OUTPUTS DC 24 V

SIPART DR24 MULTI-FUNCTION UNIT FOR AC/DC 24 V POWER SUPPLY BASIC DEVICE WITH - 3 ANALOG INPUTS 0/4-20 MA OR 0/2-10 V - 3 ANALOG OUTPUTS 0/4-20 MA - 4 DIGITAL INPUTS DC 24 V - 8 DIGITAL OUTPUTS DC 24 V

SIPART DR24 MULTI-FUNCTION UNIT FOR AC 230/115 V POWER SUPPLY BASIC DEVICE WITH - 3 ANALOG INPUTS 0/4-20 MA OR 0/2-10 V - 3 ANALOG OUTPUTS 0/4-20 MA - 4 DIGITAL INPUTS DC 24 V - 8 DIGITAL OUTPUTS DC 24 V

INTELLIGENT SIPART PS2 ELECTROPNEUMATIC POSITIONER FOR PNEUMATIC LINEAR AND PART-TURN ACTUATORS, 2-WIRE, WITHOUT HART-INTERFACE, SINGLE ACTION, HOUSING: MAKROLON WITH FIXABLE SLIPPING CLUTCH WITHOUT EX-APPROVAL CONNECTION THREAD : EL.: M20X1,5 / MEC.: G1/4 WITHOUT LIMIT MONITOR WITH IY MODULE FOR POSITION FEEDBACK (4 ... 20 MA) (6DR4004-.J), INCL. 2ND CABLE GLAND . INSTRUCTION MANUAL: GERMAN, ENGLISH . WITH MOUNTED GAUGE BLOCK, BLOCK MATERIAL: ALUMINIUM SINGLE ACTING G1/4 INCH

INTELLIGENT SIPART PS2 ELECTROPNEUMATIC POSITIONER FOR PNEUMATIC LINEAR AND PART-TURN ACTUATORS, 2-WIRE, WITHOUT HART-INTERFACE, SINGLE ACTION, HOUSING: MAKROLON WITH FIXABLE SLIPPING CLUTCH WITHOUT EX-APPROVAL CONNECTION THREAD : EL.: M20X1,5 / MEC.: G1/4 WITH LIMIT MONITOR BUILT-IN, INCL.2ND CABLE GLAND, ALARM MODULE, ELECTRONIC (6DR4004-.A) WITHOUT OPTION MODULE . INSTRUCTION MANUAL: GERMAN, ENGLISH . WITHOUT ATTACHED GAUGE BLOCK ASSEMBLY

INTELLIGENT SIPART PS2 ELECTROPNEUMATIC POSITIONER FOR PNEUMATIC LINEAR AND PART-TURN ACTUATORS, 2-WIRE, WITHOUT HART-INTERFACE, SINGLE ACTION, HOUSING: MAKROLON WITH FIXABLE SLIPPING CLUTCH WITHOUT EX-APPROVAL CONNECTION THREAD : EL.: M20X1,5 / MEC.: G1/4 WITH MECHANICAL LIMIT SWITCH MODULE (6DR4004-K) """"""""""""""""""""""""""""""" ATTENTION: WHEN THE MODULE 6DR4004-6K IS USED, THE EX-CERTIFICATION ACC. TO CSA FOR THE BASIC UNIT IS NOT VALID """"""""""""""""""""""""""""""" WITH IY MODULE FOR POSITION FEEDBACK (4 ... 20 MA) (6DR4004-.J), INCL. 2ND CABLE GLAND . INSTRUCTION MANUAL: GERMAN, ENGLISH . WITHOUT ATTACHED GAUGE BLOCK ASSEMBLY"

Control valve positioner PS2 4-20MA 1.4-7 BAR for pneumatic linear and part-turn actuators.

INTELLIGENT SIPART PS2 ELECTROPNEUMATIC POSITIONER FOR PNEUMATIC LINEAR AND PART-TURN ACTUATORS 2-WIRE, WITHOUT HART-INTERFACE, DOUBLE ACTION, HOUSING: ALUMINIUM (EEX D) WITH FIXABLE SLIPPING CLUTCH. WITH EXPLOSION PROTECTION EEX D (CENELEC/FM/CSA) CONNECTION THREAD: EL.: 1/2 INCH NPT MEC.: 1/4 INCH NPT WITH LIMIT MONITOR BUILT-IN, INCL.2ND CABLE GLAND, ALARM MODULE, ELECTRONIC (6DR4004-.A) WITHOUT OPTION MODULE . INSTRUCTION MANUAL: GERMAN, ENGLISH . WITHOUT ATTACHED GAUGE BLOCK ASSEMBLY

INTELLIGENT SIPART PS2 ELECTROPNEUMATIC POSITIONER FOR PNEUMATIC LINEAR AND PART-TURN ACTUATORS 2-WIRE, WITH HART-INTERFACE, SINGLE ACTION, HOUSING: MAKROLON WITH FIXABLE SLIPPING CLUTCH. WITHOUT EX-APPROVAL, CONNECTION THREAD: EL.: 1/2 INCH NPT MEC.: 1/4 INCH NPT WITHOUT LIMIT MONITOR WITHOUT OPTION MODULE . INSTRUCTION MANUAL: GERMAN, ENGLISH . WITH MOUNTED GAUGE BLOCK, BLOCK MATERIAL: ALUMINIUM SINGLE ACTING, NPT

SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn actuators

SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn actuators

SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn actuators

SITRANS P210 TRANSMITTERS FOR PRESSURE AND ABSOLUTE PRESSURE FOR LOW-PRESSURE APPLICATIONS NON-LINEARITY: 0,25 PERCENT (TYPICALLY) WETTED PARTS MATERIAL: STAINLESS STEEL PLUS SEALING MATERIAL, NON-WETTED PARTS MATERIAL: STAINLESS STEEL MEASURING RANGE FOR GAUGE: 0 TO 250 MBAR, OVERLOAD- PRESSURE 1 BAR OUTPUT SIGNAL: 4 TO 20 MA TWO-WIRE CONNECTION, POWER SUPPLY DC 7 TO 33 V WITHOUT EXPLOSION PROTECTION ELECTRICAL CONNECTION: PLUG TO DIN EN 175301-803-A, THREAT FOR PACKED GLAND M16 (WITH CONNECTOR) PROCESS CONNECTION: G1/2&quot, MALE TO EN 837-1 (1/2&quot, BSP MALE) (STANDARD FOR METRIC PRESSURE RANGES MBAR, BAR) SEALING MATERIAL BETWEEN SENSOR AND HOUSING: VITON (FPM, STANDARD) STANDARD VERSION

SITRANS P210 TRANSMITTERS FOR PRESSURE AND ABSOLUTE PRESSURE FOR LOW-PRESSURE APPLICATIONS NON-LINEARITY: 0,25 PERCENT (TYPICALLY) WETTED PARTS MATERIAL: STAINLESS STEEL PLUS SEALING MATERIAL, NON-WETTED PARTS MATERIAL: STAINLESS STEEL MEASURING RANGE FOR GAUGE: 0 TO 400 MBAR, OVERLOAD- PRESSURE 1 BAR OUTPUT SIGNAL: 4 TO 20 MA TWO-WIRE CONNECTION, POWER SUPPLY DC 7 TO 33 V WITHOUT EXPLOSION PROTECTION ELECTRICAL CONNECTION: PLUG TO DIN EN 175301-803-A, THREAT FOR PACKED GLAND M16 (WITH CONNECTOR) PROCESS CONNECTION: G1/2&quot, MALE TO EN 837-1 (1/2&quot, BSP MALE) (STANDARD FOR METRIC PRESSURE RANGES MBAR, BAR) SEALING MATERIAL BETWEEN SENSOR AND HOUSING: VITON (FPM, STANDARD) STANDARD VERSION

SITRANS P210 TRANSMITTERS FOR PRESSURE AND ABSOLUTE PRESSURE FOR LOW-PRESSURE APPLICATIONS NON-LINEARITY: 0,25 PERCENT (TYPICALLY) WETTED PARTS MATERIAL: STAINLESS STEEL PLUS SEALING MATERIAL, NON-WETTED PARTS MATERIAL: STAINLESS STEEL MEASURING RANGE FOR GAUGE: 0 TO 600 MBAR, OVERLOAD- PRESSURE 3 BAR OUTPUT SIGNAL: 4 TO 20 MA TWO-WIRE CONNECTION, POWER SUPPLY DC 7 TO 33 V WITHOUT EXPLOSION PROTECTION ELECTRICAL CONNECTION: PLUG TO DIN EN 175301-803-A, THREAT FOR PACKED GLAND M16 (WITH CONNECTOR) PROCESS CONNECTION: G1/2&quot, MALE TO EN 837-1 (1/2&quot, BSP MALE) (STANDARD FOR METRIC PRESSURE RANGES MBAR, BAR) SEALING MATERIAL BETWEEN SENSOR AND HOUSING: VITON (FPM, STANDARD) STANDARD VERSION

SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEuropean Article NumberING SPAN: PN 32 (MWP 464 PSI): 1 TO 20 MBAR (0.4015 TO 8.03 INH2O), MAX. STATIC PRESSURE 32 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: 7/16-20 UNF DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL INTERNATIONAL DESIGN ENGLISH INSCRIPTION DOCUMENTATION AS CD ATEX (EX IA + EX D + ZONE 1D/2D) ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X1.5 HOUSING COVER WITH WINDOW

SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEuropean Article NumberING SPAN: PN 160 (MWP 2320 PSI): 1 TO 60 MBAR (0.4015 TO 24.09 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: 7/16-20 UNF DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL STANDARD DESIGN . WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND 1/2-14 NPT HOUSING COVER WITH WINDOW

SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEuropean Article NumberING SPAN: PN 160 (MWP 2320 PSI): 1 TO 60 MBAR (0.4015 TO 24.09 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: 7/16-20 UNF DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL INTERNATIONAL DESIGN ENGLISH INSCRIPTION DOCUMENTATION AS CD ATEX (EX IA + EX D + ZONE 1D/2D) ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X1.5 HOUSING COVER WITH WINDOW

SITRANS P DS III / P410, PROFIBUS PA, transmitter

SITRANS P DS III / P410, PROFIBUS PA, transmitter

SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 420 MEASURING CELL FILLING SILICONE OIL NORMAL CLEuropean Article NumberING SPAN 16 TO 1600 MBAR (6.424 TO 642.4 INH2O), MAX.STATIC PRESSURE 420 BAR DIAPHRAGM MADE OF STAINLESS STEEL, MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: M12 DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE SCREWS STAINLESS STEEL (PN 420) INTERNATIONAL DESIGN ENGLISH INSCRIPTION DOCUMENTATION AS CD WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M 20X1.5 HOUSING COVER WITH WINDOW

SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR LEVEL MEASURING CELL FILLING SILICONE OIL NORMAL CLEuropean Article NumberING SPAN 25 TO 250 MBAR (0.363 TO 3.63 PSI) DESIGN FOR REMOTE SEALS. NOTE: PLEASE ADD THE DELIVERY TIME OF THE REMOTE SEAL! PROCESS CONNECTION: 1/4-18 NPT SECURING THREAD: 7/16-20 UNF DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS MADE OF STAINLESS STEEL INTERNATIONAL DESIGN ENGLISH INSCRIPTION DOCUMENTATION AS CD WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M 20X1.5 WITHOUT VISIBLE DIGITAL INDICATOR (DIGITAL DISPLAY HIDDEN, SETTING: MA)

SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR LEVEL MEASURING CELL FILLING SILICONE OIL NORMAL CLEuropean Article NumberING SPAN 25 TO 600 MBAR (0.363 TO 8.70 PSI) DESIGN FOR REMOTE SEALS. NOTE: PLEASE ADD THE DELIVERY TIME OF THE REMOTE SEAL! PROCESS CONNECTION: 1/4-18 NPT SECURING THREAD: M10 DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS MADE OF STAINLESS STEEL STANDARD DESIGN WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND PG 13.5 (NOT WITH EXPLOSION PROOF) WITHOUT VISIBLE DIGITAL INDICATOR (DIGITAL DISPLAY HIDDEN, SETTING: MA)

SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR LEVEL MEASURING CELL FILLING SILICONE OIL NORMAL CLEuropean Article NumberING SPAN 53 TO 1600 MBAR (0.77 TO 23.2 PSI) DESIGN FOR REMOTE SEALS. NOTE: PLEASE ADD THE DELIVERY TIME OF THE REMOTE SEAL! PROCESS CONNECTION: 1/4-18 NPT SECURING THREAD: M10 DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS MADE OF STAINLESS STEEL INTERNATIONAL DESIGN ENGLISH INSCRIPTION DOCUMENTATION AS CD EXPLOSION PROTECTION EEX D ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M 20X1.5 HOUSING COVER WITH WINDOW

SITRANS P TRANSMITTER COMPACT FOR PRESSURE AND ABSOLUT PRESSURE FOR FOOD, PHARMACEU- TICALS AND BIOTECHNOLOGY, WITH DIAPHRAGM FLUSH AT FRONT. 2-WIRE SYSTEM, PROCESS TEMPERA- TURE UP TO 140 DEG. CEL., ACCURACY 0.2 % OF F.S.V. OUTPUT SIGNAL: 4...20 MA, PROCESS CONNECTION: QUICK-RELEASE CONNECTION: CLAMP CONNECTION ACCORDING DIN 32676: DN 40 FILLING LIQUID: LIQUID FDA APPROVED OUTPUT SIGNAL : 4-20 MA HOUSING(STAINLESS STEEL1.4404)/ ELECTRICAL CONNECTION: HOUSING WITH ANGELD PLUG ACCORDING DIN 43650, IP65 MEASURING RANGE: 0...160 MBAR OVERLOAD PRESSURE: 2 BAR WITHOUT EXPLOSION PROTECTION

SITRANS P TRANSMITTER COMPACT FOR PRESSURE AND ABSOLUT PRESSURE FOR FOOD, PHARMACEU- TICALS AND BIOTECHNOLOGY, WITH DIAPHRAGM FLUSH AT FRONT. 2-WIRE SYSTEM, PROCESS TEMPERA- TURE UP TO 140 DEG. CEL., ACCURACY 0.2 % OF F.S.V. OUTPUT SIGNAL: 4...20 MA, PROCESS CONNECTION: QUICK-RELEASE CONNECTION: CLAMP CONNECTION ACCORDING DIN 32676: DN 40 FILLING LIQUID: LIQUID FDA APPROVED OUTPUT SIGNAL : 4-20 MA HOUSING(STAINLESS STEEL1.4404)/ ELECTRICAL CONNECTION: HOUSING WITH ANGELD PLUG ACCORDING DIN 43650, IP65 MEASURING RANGE: 0...400 MBAR OVERLOAD PRESSURE: 6 BAR WITHOUT EXPLOSION PROTECTION

SITRANS P TRANSMITTER COMPACT FOR PRESSURE AND ABSOLUT PRESSURE FOR FOOD, PHARMACEU- TICALS AND BIOTECHNOLOGY, WITH DIAPHRAGM FLUSH AT FRONT. 2-WIRE SYSTEM, PROCESS TEMPERA- TURE UP TO 140 DEG. CEL., ACCURACY 0.2 % OF F.S.V. OUTPUT SIGNAL: 4...20 MA, PROCESS CONNECTION: QUICK-RELEASE CONNECTION: CLAMP CONNECTION ACCORDING DIN 32676: DN 40 FILLING LIQUID: LIQUID FDA APPROVED OUTPUT SIGNAL : 4-20 MA HOUSING(STAINLESS STEEL1.4404)/ ELECTRICAL CONNECTION: HOUSING WITH ANGELD PLUG ACCORDING DIN 43650, IP65 MEASURING RANGE: 0...6 BAR OVERLOAD PRESSURE: 30 BAR WITHOUT EXPLOSION PROTECTION

ECHOMAX XPS-30 TRANSDUCER HIGH-FREQUENCY ULTRASONIC TRANSDUCER DESIGNED FOR A WIDE VARIETY OF LIQUID AND SOLID APPLICATIONS, FOR USE WITH APPROVED CONTROLLERS. INCLUDES INTEGRAL TEMPERATURE SENSOR. 1 1/2&quot, UNIVERSAL THREAD COMPATIBLE WITH 1 1/2&quot, NPT AND R 1 1/2&quot, ((BSPT), EN 10226) MEASURING RANGE: MIN. 0.6M (1.97 FT), MAX. 30M (98.43 FT) MOUNTING THREAD AND FACING: 1 1/2&quot, UNIVERSAL THREAD CABLE LENGTH: 5 M (16.40 FT) FLANGE: WITHOUT MOUNTING FLANGE APPROVALS: ATEX II 2G 1D, FM CLASS 1 DIV 2 SAA INSTRUCTION MANUAL: MULTI-LANGUAGE QUICK START

ECHOMAX XPS-30 TRANSDUCER HIGH-FREQUENCY ULTRASONIC TRANSDUCER DESIGNED FOR A WIDE VARIETY OF LIQUID AND SOLID APPLICATIONS, FOR USE WITH APPROVED CONTROLLERS. INCLUDES INTEGRAL TEMPERATURE SENSOR. 1 1/2&quot, UNIVERSAL THREAD COMPATIBLE WITH 1 1/2&quot, NPT AND R 1 1/2&quot, ((BSPT), EN 10226) MEASURING RANGE: MIN. 0.6M (1.97 FT), MAX. 30M (98.43 FT) MOUNTING THREAD AND FACING: 1 1/2&quot, UNIVERSAL THREAD CABLE LENGTH: 10 M (32.81 FT) FLANGE: DN 150, PN10/16, TYPE A, FLAT FACED APPROVALS: ATEX II 2G 1D, FM CLASS 1 DIV 2 SAA INSTRUCTION MANUAL: MULTI-LANGUAGE QUICK START


in international format without spaces