6XV1873 SERIES SIMATIC NET FO STANDARD CABLE GP (50/125), 12.04 Kg, Pkg. 1x1x1 (mm)

6XV1440 SERIES CONNECTING CABLE FOR MOBILE PANELS (MPI/PROFIBUS), ST80.1Q, 0.31 Kg, Pkg. 23,10x24,20x5,80 (cm)
6XV1440 SERIES CONNECTING CABLE FOR MOBILE PANELS (MPI/PROFIBUS), ST80.1Q, 0.59 Kg, Pkg. 25,10x25,60x7,40 (cm)
6XV1440 SERIES CONNECTING CABLE FOR MOBILE PANELS (MPI/PROFIBUS), ST80.1Q, 1.033 Kg, Pkg. 23,80x25,60x10,40 (cm)
6XV1440 SERIES CONNECTING CABLE FOR MOBILE PANELS (MPI/PROFIBUS), ST80.1Q, 1.525 Kg, Pkg. 26,10x27,70x9,60 (cm)
6XV1440 SERIES CONNECTING CABLE PN FOR MOBILE PANELS (PROFINET), ST80.1Q, 0.351 Kg, Pkg. 21,70x23,80x6,10 (cm)
6XV1440 SERIES CONNECTING CABLE PN FOR MOBILE PANELS (PROFINET), ST80.1Q, 0.698 Kg, Pkg. 24,80x26,40x8,60 (cm)
6XV1440 SERIES CONNECTING CABLE PN FOR MOBILE PANELS (PROFINET), ST80.1Q, 1.059 Kg, Pkg. 26x26x5 (cm)
6XV1440 SERIES CONNECTING CABLE PN FOR MOBILE PANELS (PROFINET), ST80.1Q, 1.296 Kg, Pkg. 25,10x26,60x7,40 (cm)
6XV1440 SERIES CONNECTING CABLE PN FOR MOBILE PANELS (PROFINET), ST80.1Q, 1.864 Kg, Pkg. 25,70x26,80x14 (cm)
6XV1440 SERIES CONNECTING CABLE PN FOR MOBILE PANELS (PROFINET), ST80.1Q, 2.48 Kg, Pkg. 27,90x28,60x8,10 (cm)
6XV1440 SERIES CONNECTING CABLE PN FOR MOBILE PANELS (PROFINET), ST80.1Q, 3.105 Kg, Pkg. 33,70x35,60x8,30 (cm)
6XV1801 SERIES POWER CONNECTING CABLE M12-180/M12-180 FOR POWER SUPPLY OF ET200, 0.055 Kg, Pkg. 1x1x1 (mm)
6XV1801 SERIES POWER CONNECTING CABLE M12-180/M12-180 FOR POWER SUPPLY OF ET200, 0.295 Kg, Pkg. 1x1x1 (mm)
6XV1801 SERIES POWER CONNECTING CABLE M12-180/M12-180 FOR POWER SUPPLY OF ET200, 0.55 Kg, Pkg. 1x1x1 (mm)
6XV1820 SERIES SIMATIC NET, 0.085 Kg, Pkg. 15x15x1 (cm)
6XV1821 SERIES SIMATIC NET, 2.9 Kg, Pkg. 32x32x8 (cm)
6XV1822 SERIES SIMATIC NET, 1.769 Kg, Pkg. 1x1x1 (mm)
6XV1822 SERIES SIMATIC NET, 2.54 Kg, Pkg. 1x1x1 (mm)
6XV1830 SERIES SIMATIC NET, 4.12 Kg, Pkg. 30,40x32,50x7,90 (cm)
6XV1830 SERIES SIMATIC NET, 8.06 Kg, Pkg. 50x50x13 (cm)
6XV1830 SERIES SIMATIC NET, 16.36 Kg, Pkg. 48x48x13 (cm)
6XV1830 SERIES SIMATIC NET, 42 Kg, Pkg. 40x40x40 (cm)
6XV1830 SERIES SIMATIC NET, 81 Kg, Pkg. 60x60x47,50 (cm)
6XV1830 SERIES SIMATIC NET, 0.54 Kg, Pkg. 27,90x32,90x4,60 (cm)

The Product is not Available now!

Check the Price with the manager.

6XV1840 SERIES Industrial Ethernet FC TP STANDARD CABLE, 0.063 Kg, Pkg. 1x07x1 (cm)

6XV1840 SERIES SIMATIC NET, 68 Kg, Pkg. 60x60x48 (cm)
6XV1870 SERIES SIMATIC NET, 1.1 Kg, Pkg. 1x1x1 (mm)
6XV1871 SERIES IE CONNECTING CABLE IE FC RJ45 PLUG-180/IE FC RJ45 PLUG-180, 0.18 Kg, Pkg. 1x1x1 (mm)
6XV1871 SERIES IE CONNECTING CABLE M12-180/IE FC RJ45 PLUG-145, 0.75 Kg, Pkg. 1x1x1 (mm)

Cables are an irreplaceable thing in any conditions. They are used in offices, cars, factories, on the streets. It is difficult to imagine the modern world without cables, as it is often the only link between several devices. Damage to even one cable can cause serious damage to production activities and even lead to a series of other, even more unpleasant consequences. When choosing, you should definitely pay attention to the density of the cable, the material used for insulation, the strength of the main part.

Product Advantages

Cables from the manufacturer Siemens outperform their competitors. The manufacturer has tried and equipped its products with increased defense contrary mechanic loss, which will help to get away random wreck. Also, Siemens cables have in their arsenal protection against water and dust penetration (under the insulating material). Siemens cables have a very dense insulating part, so it is difficult to damage it, which automatically reduces the chance of serious damage. The cables are of very high quality and are the best option for working in hazardous industries, industries with high load or for work in rooms with high humidity.

Industrial networks PROFINET/Industrial Ethernet have wide functionality, high flexibility and throughput, and are used at all levels of industrial enterprise management. SIEMENS provides support

  • Industrial networks Industrial Ethernet that meet the requirements of international norms IEEE 802.3 (Ethernet) and IEEE 802.11 a/b/g/h/n (WLAN).
  • Industrial networks PROFINET (PN) based on Industrial Ethernet, focused on application in automation systems that meet the requirements of the international standard IEC 61158 and allow real-time data swap.

Electrical cables and TP cords

PROFINET/Industrial Ethernet networks use TR (Twisted Pair) cables and cords. TP PN/IE electrical cables are accessible in different releases, differing in core and sheath insulation materials, permissible operating conditions, category and number of twisted pairs, as well as support (TP FC) or without support. (TP) Fast Connect (FC) technology. Cables are delivered in the form of ordered lengths falling within the range of minimum and maximum release rates.

TR cords are ready-made connecting standard length cables with installed connectors. The maximum length of a TP cord can be up to 10 m. TP cords are available with straight or crossed (XP) cable cores between connectors. Traditionally, TP XP cords are used to directly connect two network devices to each other.

Connectors for electrical cables

Several types of connectors can be used to make electrical connections in networks. At the same time, Fast Connect technology is predominantly used in all new types of jumpers. IE FC RJ45 gabs are available in metal cases and mounted directly on IE FC TP 2x2 or 4x2 cables. The cable is connected by piercing the core insulation (Fast Connect), the plug contacts are color-coded corresponding to the colors of the sheaths of the cores of the coupled cable.

The IE FC RJ45 modular socket is highly versatile and can be used in networks with data rates up to 1000 Mbps. Each modular socket consists of a base module and an insert. The base module is mounted on a flat surface or on a DIN rail. It is equipped contacts for connecting one 8-core (4x2) IE TP cable, as well as a compartment for installing an insert.

Connecting the IE TP cable of the communication line is carried out by the method piercing the insulation of the cores in accordance with the color setting of the contacts. Possible options for connecting external devices are determined by the type of insert used:

  • The 2FE insert has two 10/100 Mbps RJ45 sockets.
  • 1GE insert with one RJ45 10/100/1000 Mbps joint.
  • Power insert with one RJ45 10/100 Mbps socket and 24 VDC power deliver interface.