Siemens Level switches

SITRANS LR250, 25 GHz pulse level radar

The Product is not Available now!

Check the Price with the manager.

RS1E-X for ET200S High Feature reversing starter

The Product is not Available now!

Check the Price with the manager.

RS1-X for ET 200S Standard reversing starter expandable

The Product is out of Production!

Contact the manager for more information.

  • Power supply: 19 to 230 V AC
  • 19 to 55 V DC
  • two relay outputs (DPDT)

Electronic overload protection up to 0.25 kW / 400 V
Setting range 0.3–1 A

Direct starter with extended functionality

Electronic overload protection up to 0.25 kW / 500 V

KIT,ROPE EXTENSION,SS,L=2000MM
REPLACEMENT ELECTRONICS MODULE FOR POINTEK LVS200, 350 HZ (19 TO 230 V AC, 19 TO 55 V DC, ONE RELAY OUTPUT (SPDT))
SITRANS LPS COMPACT: ROTARY PADDLE SWITCH FOR LEVEL DETECTION IN BULK SOLIDS. COMPACT DESIGN FOR SIDE OR TOP MOUNTED APPLICATIONS PROCESS TEMPERATURE: UP TO +80 C (+176 F) POWER SUPPLY: 230 V AC, 1 REV/MIN. PROCESS CONNECTION THREADED: G 1-1/2", ((BSPP), EN ISO 228-1) PROCESS PRESSURE: UP TO 0.5 BAR (7.25 PSI) PROCESS CONNECTION MATERIAL: STAINLESS STEEL 303 (1.4305) FLANGES 321 (1.4541), TRI-CLAMP 304 (1.4301) EXTENSION LENGTH: 150 MM (5.91 INCH) MEASURING VANE: BOOT SHAPED, 35 X 106 MM (1.38 X 4.17 INCH) APPROVALS: CE, C-TICK .
SITRANS LPS COMPACT: ROTARY PADDLE SWITCH FOR LEVEL DETECTION IN BULK SOLIDS. COMPACT DESIGN FOR SIDE OR TOP MOUNTED APPLICATIONS PROCESS TEMPERATURE: UP TO +80 C (+176 F) POWER SUPPLY: 24 V DC, 1 REV/MIN. PROCESS CONNECTION THREADED: G 1-1/2", ((BSPP), EN ISO 228-1) PROCESS PRESSURE: UP TO 0.5 BAR (7.25 PSI) PROCESS CONNECTION MATERIAL: ALUMINUM EXTENSION LENGTH: 100 MM (3.94 INCH) MEASURING VANE: BOOT SHAPED, 35 X 106 MM (1.38 X 4.17 INCH) APPROVALS: ATEX II 1/2 D, C-TICK .
SITRANS LPS COMPACT: ROTARY PADDLE SWITCH FOR LEVEL DETECTION IN BULK SOLIDS. COMPACT DESIGN FOR SIDE OR TOP MOUNTED APPLICATIONS PROCESS TEMPERATURE: UP TO +600 C (+1112 F) POWER SUPPLY: 24 V DC, 1 REV/MIN. PROCESS CONNECTION THREADED: G 1-1/2", ((BSPP), EN ISO 228-1) PROCESS PRESSURE: UP TO 0.5 BAR (7.25 PSI) PROCESS CONNECTION MATERIAL: STAINLESS STEEL 303 (1.4305) FLANGES 321 (1.4541), TRI-CLAMP 304 (1.4301) EXTENSION LENGTH: 200 MM (7.87 INCH) MEASURING VANE: BOOT SHAPED, 35 X 106 MM (1.38 X 4.17 INCH) APPROVALS: CE, C-TICK .
SITRANS LPS COMPACT: ROTARY PADDLE SWITCH FOR LEVEL DETECTION IN BULK SOLIDS. COMPACT DESIGN FOR SIDE OR TOP MOUNTED APPLICATIONS PROCESS TEMPERATURE: UP TO +80 C (+176 F) BASIC VERSION ALUMINUM POWER SUPPLY: 230 V AC, 1 REV/MIN. PROCESS CONNECTION THREADED: G 1-1/2", ((BSPP), EN ISO 228-1) PROCESS PRESSURE: UP TO 0.5 BAR (7.25 PSI) PROCESS CONNECTION MATERIAL: ALUMINUM EXTENSION LENGTH: 150 MM (5.91 INCH) MEASURING VANE: BOOT SHAPED, 35 X 106 MM (1.38 X 4.17 INCH) APPROVALS: CE, C-TICK .
SITRANS LPS200, EXTENDED WITH PROTECTION SHAFT: ROTARY PADDLE SWITCH FOR LEVEL DETECTION IN BULK SOLIDS. EXTENDED DESIGN WITH PROTECTION TUBE FOR ADDED SHAFT PROTECTION. PROCESS TEMPERATURE: UP TO +80 C (+176 F) POWER SUPPLY: 24 V DC, 1 REV/MIN. PROCESS CONNECTION THREADED: 1-1/4", NPT ((TAPER), ANSI/ASME B1.20.1) PROCESS PRESSURE: UP TO 0.5 BAR (7.25 PSI) PROCESS CONNECTION MATERIAL: ALUMINUM EXTENSION LENGTH: 150 MM (5.91 INCH) EXTENSION MATERIAL (PROTECTION TUBE): ALUMINUM MEASURING VANE: BOOT SHAPED, 35 X 106 MM (1.38 X 4.17 INCH) APPROVALS: ATEX II 1/2 D, C-TICK
SITRANS LPS 200: ROTARY PADDLE SWITCH FOR LEVEL DETECTION IN BULK SOLIDS. CABLE EXTENSION FOR INCREASED LENGTH IN TOP-MOUNTED APPLICATIONS. PROCESS TEMPERATURE: UP TO +80 C (+176 F) POWER SUPPLY: 230 V AC, 1 REV/MIN. PROCESS CONNECTION THREADED: G 1-1/2", ((BSPP), EN ISO 228-1) PROCESS PRESSURE: UP TO 0.5 BAR (7.25 PSI) PROCESS CONNECTION MATERIAL: STAINLESS STEEL, THREADS 303 (1.4305),FLANGES 321 (1.4541) CABLE EXTENSION LENGTH: STANDARD CABLE LENGTH, 2000 MM (78.74 INCH) MEASURING VANE: HINGED VANE, 65 X 210 MM (2.56 X 8.27 INCH) APPROVALS: ATEX II 1/2 D, C-TICK .
SITRANS LVS 100 STANDARD : VIBRATING POINT LEVEL SWITCH FOR HIGH OR LOW LEVELS OF BULK SOLIDS. SENSITIVITY >,60G/L. INPUT VOLTAGE: DPDT RELAY - 19 TO 230 V AC, 19 TO 40 V DC PROCESS TEMPERATURE: UP TO +150 C (+302 F) PROCESS CONNECTION THREADED: R 1 1/2", ((BSPT), EN 10226) EXTENSION LENGTH: STAINLESS STEEL 316TI (1.4571): STANDARD LENGTH, 170 MM (6.69 INCH) . APPROVALS: CSA/FM GENERAL PURPOSE, CE, C-TICK . .
SITRANS LVS 100 STANDARD : VIBRATING POINT LEVEL SWITCH FOR HIGH OR LOW LEVELS OF BULK SOLIDS. SENSITIVITY >,60G/L. INPUT VOLTAGE: DPDT RELAY - 19 TO 230 V AC, 19 TO 40 V DC PROCESS TEMPERATURE: UP TO +150 C (+302 F) PROCESS CONNECTION THREADED: R 1 1/2", ((BSPT), EN 10226) EXTENSION LENGTH: STAINLESS STEEL 316TI (1.4571): STANDARD LENGTH, 170 MM (6.69 INCH) . APPROVALS: CSA/FM CLASS II, DIV. 1, GROUP E,F, G, CLASS III, ATEX II 1/2 D, C-TICK . .
SITRANS LVS 100 STANDARD : VIBRATING POINT LEVEL SWITCH FOR HIGH OR LOW LEVELS OF BULK SOLIDS. SENSITIVITY >,60G/L. INPUT VOLTAGE: DPDT RELAY - 19 TO 230 V AC, 19 TO 40 V DC, (STOCKED VERSION) PROCESS TEMPERATURE: UP TO +150 C (+302 F) PROCESS CONNECTION THREADED: R 1 1/2", ((BSPT), EN 10226) EXTENSION LENGTH: STAINLESS STEEL 316TI (1.4571): STANDARD LENGTH, 170 MM (6.69 INCH) . APPROVALS: CSA/FM GENERAL PURPOSE, CE, C-TICK . .

The indicated price is the minimum price for products in this series!

COMPACT VIBRATING LEVEL SWITCH

SITRANS LVL100: COMPACT VIBRATING LEVEL SWITCH FOR USE IN LIQUID APPLICATIONS SUCH AS OVERFLOW, HIGH, LOW AND DEMAND APPLICATIONS, AS WELL AS PUMP PROTECTION. IDEAL FOR USE IN CONFINED SPACES. APPROVALS: WITHOUT APPROVALS PROCESS TEMPERATURE: STANDARD -40 TO 100 C PROCESS CONNECTION: THREAD G 3/4&quot, A PN64 / 316L ELECTRONICS: CONTACTLESS ELECTRONIC SWITCH 20...250 V AC/DC HOUSING: 316L ELECTRICAL CONNECTION / PROTECTION: ACCORDING TO DIN 43650 INCLUDING PLUG / IP65 . .

SITRANS LVL100: COMPACT VIBRATING LEVEL SWITCH FOR USE IN LIQUID APPLICATIONS SUCH AS OVERFLOW, HIGH, LOW AND DEMAND APPLICATIONS, AS WELL AS PUMP PROTECTION. IDEAL FOR USE IN CONFINED SPACES. APPROVALS: WITHOUT APPROVALS PROCESS TEMPERATURE: STANDARD -40 TO 100 C PROCESS CONNECTION: THREAD G 3/4", A PN64 / 316L ELECTRONICS: TRANSISTOR OUTPUT PNP 10...55 V DC HOUSING: 316L ELECTRICAL CONNECTION / PROTECTION: ACCORDING TO DIN 43650 INCLUDING PLUG / IP65 . .
SITRANS LVL100: COMPACT VIBRATING LEVEL SWITCH FOR USE IN LIQUID APPLICATIONS SUCH AS OVERFLOW, HIGH, LOW AND DEMAND APPLICATIONS, AS WELL AS PUMP PROTECTION. IDEAL FOR USE IN CONFINED SPACES. APPROVALS: WITHOUT APPROVALS PROCESS TEMPERATURE: STANDARD -40 TO 100 C PROCESS CONNECTION: THREAD G1", A PN64 / 316L ELECTRONICS: CONTACTLESS ELECTRONIC SWITCH 20...250 V AC/DC HOUSING: 316L ELECTRICAL CONNECTION / PROTECTION: ACCORDING TO DIN 43650 INCLUDING PLUG / IP65 . .
SITRANS LVL100: COMPACT VIBRATING LEVEL SWITCH FOR USE IN LIQUID APPLICATIONS SUCH AS OVERFLOW, HIGH, LOW AND DEMAND APPLICATIONS, AS WELL AS PUMP PROTECTION. IDEAL FOR USE IN CONFINED SPACES. APPROVALS: WITHOUT APPROVALS PROCESS TEMPERATURE: STANDARD -40 TO 100 C PROCESS CONNECTION: THREAD G1", A PN64 / 316L ELECTRONICS: TRANSISTOR OUTPUT PNP 10...55 V DC HOUSING: 316L ELECTRICAL CONNECTION / PROTECTION: ACCORDING TO DIN 43650 INCLUDING PLUG / IP65 . .
SITRANS LVL100: COMPACT VIBRATING LEVEL SWITCH FOR USE IN LIQUID APPLICATIONS SUCH AS OVERFLOW, HIGH, LOW AND DEMAND APPLICATIONS, AS WELL AS PUMP PROTECTION. IDEAL FOR USE IN CONFINED SPACES. APPROVALS: WITHOUT APPROVALS PROCESS TEMPERATURE: EXTENDED -40 TO 150 C PROCESS CONNECTION: THREAD G 3/4", A PN64 / 316L ELECTRONICS: TRANSISTOR OUTPUT PNP 10...55 V DC HOUSING: 316L ELECTRICAL CONNECTION / PROTECTION: M12X1 / IP67 1 . .
SITRANS LVL200 STANDARD: STANDARD VIBRATING LEVEL SWITCH FOR USE IN LIQUID AND LIQUID HAZARDOUS APPLICATIONS SUCH AS OVERFLOW, HIGH, LOW AND DEMAND APPLICATIONS, AS WELL AS PUMP PROTECTION. FOR USE IN SIL-2 APPLICATIONS. ELECTRONICS: CONTACTLESS ELECTRONIC SWITCH 20...250 V AC/DC APPROVALS: ATEX II 1/2G, 2G EEX D IIC T6 + WHG PROCESS CONNECTION / MATERIAL: THREAD G 3/4", A, PN64 / 316L ADAPTER/PROCESS TEMPERATURE: WITHOUT ADAPTER/ -50...150 C HOUSING/CABLE ENTRY: ALUMINIUM IP66/IP67 / M20X1.5 . .
SITRANS LVL200 STANDARD: STANDARD VIBRATING LEVEL SWITCH FOR USE IN LIQUID AND LIQUID HAZARDOUS APPLICATIONS SUCH AS OVERFLOW, HIGH, LOW AND DEMAND APPLICATIONS, AS WELL AS PUMP PROTECTION. FOR USE IN SIL-2 APPLICATIONS. ELECTRONICS: CONTACTLESS ELECTRONIC SWITCH 20...250 V AC/DC APPROVALS: ATEX II 1/2G, 2G EEX D IIC T6 + WHG PROCESS CONNECTION / MATERIAL: TRI-CLAMP 2",, PN16 / 316L RA<,0.8 MICROMETERS ADAPTER/PROCESS TEMPERATURE: WITHOUT ADAPTER/ -50...150 C HOUSING/CABLE ENTRY: ALUMINIUM IP66/IP67 / M20X1.5 . .

Siemens offers a wide range of industrial level sensors designed to monitor liquid levels in various industrial applications. These devices can be used to control pumps, valves, and other devices depending on the liquid level in reservoirs, tanks, or wells. Today, we will look at Siemens level switches in more detail.

Explore the Range of Siemens Level Switches

If you decide to choose a Siemens level switch, you should be prepared that the choice will not be straightforward, given the wide range of products. Let's find out exactly what devices the company offers.

Float level switches
Siemens manufactures float level switches that use the buoyancy principle. These switches are typically used in applications where liquid levels must be monitored or controlled. Depending on the specific application requirements, they can be installed vertically or horizontally.

Capacitive level sensors
Capacitive level sensors from Siemens are designed to detect the presence or absence of liquid or solid material. They work based on a change in capacitance between the sensor and the target substance. These switches are often used in applications where contact with the material is undesirable or impossible.

Ultrasonic level sensors
Siemens ultrasonic level switch uses ultrasonic technology to detect the level of liquid or solid materials in a container. They emit ultrasonic pulses and measure the time it takes for them to be reflected to the sensor. These switches are suitable for various applications and provide non-contact level measurement.

Vibrating level switches
Vibrating level switches work by detecting changes in vibration frequency caused by the presence or absence of material. Siemens offers vibrating level sensors suitable for both liquids and solids. They are often used when the measured material is sticky, viscous, or prone to deposits.

Guided wave radar level sensors
Siemens Guided Wave Radar Level Sensors use radar technology to measure the level of liquids, solids, and interface layers. They emit radar pulses along a probe or cable, and the reflected signals are analyzed to determine the level of the material. These switches suit demanding applications such as high temperatures, pressures, or aggressive environments.

Hydrostatic level sensors
Siemens hydrostatic level sensors use hydrostatic pressure to detect liquid levels. They are often used in applications where the process pressure is constant and the fluid's specific gravity is known. These switches are simple in design and provide reliable level detection.

Point Level Switches

Siemens offers a range of point level switches designed for various industrial applications. These switches are used to detect the presence or absence of material at a particular point within a container or vessel. Some of the popular liquid level switch models include:

  • SITRANS LVL100. This is a vibrating level switch suitable for solids and liquids. It is particularly useful in applications where material buildup is a concern.
  • SITRANS LVS100. This is a capacitance point level switch designed for liquids, slurries, and solids. It offers high sensitivity and can be used in a wide range of industries.
  • SITRANS LPS200. This is a capacitance level switch primarily designed for liquids and slurries. It provides reliable level detection in challenging process conditions.
  • SITRANS LVS200. Another capacitance point level switch from Siemens is suitable for liquids, slurries, and solids. It offers robust construction and precise level detection.
  • SITRANS LVS300. This is a rotary paddle level switch designed for bulk solids. It offers simple installation and reliable operation, even in dusty environments.
  • SITRANS LPS300. A capacitance level switch is suitable for liquids and slurries. It offers advanced diagnostics and is suitable for demanding process applications.
  • SITRANS LPS400. This is a vibrating point level switch designed for liquids and solids. It offers high sensitivity and can detect a wide range of materials.

Continuous Level Switches

Siemens offers a range of continuous level switches designed to provide accurate and reliable level measurements in various industrial applications. These switches are used to monitor the level of liquids or solids in tanks, vessels, and silos continuously.
One of the popular products in Siemens' continuous level switch lineup is the SITRANS LG series. These switches utilize different technologies such as radar, ultrasonic, and guided wave radar to suit different application requirements. They are known for their robust construction, high accuracy, and ease of installation and maintenance.
The SITRANS LG series includes models such as:

  • SITRANS LG240. This is an ultrasonic level transmitter suitable for continuous level measurement of liquids and slurries. It offers reliable performance even in challenging environments.
  • SITRANS LG250. This is a radar level transmitter designed for continuous level measurement of liquids, slurries, and solids. It provides accurate measurements even in applications with extreme conditions such as high temperatures and pressures.
  • SITRANS LG260. This is a guided wave radar level transmitter suitable for continuous level measurement of liquids and solids. It is particularly useful in applications where there are changes in temperature, pressure, or dielectric constant.

Selecting the Right Siemens Level Switch

When you choose equipment for industrial purposes, your choice should be influenced not only by Siemens level switch price but also by several other factors:

  • Determine whether you require spot level measurement (on/off control) or continuous level measurement (continuous monitoring). Consider factors such as measurement range, accuracy requirements, response time, and required output signals (analog, digital, or both).
  • Understand whether you are measuring liquids, suspensions, or solids. Consider the physical and chemical properties of the medium, such as density, viscosity, dielectric constant, and particle size.
  • Consider factors such as temperature, pressure, humidity, and the presence of corrosive or abrasive materials. Choose a level switch that can withstand the environmental conditions of your application without compromising performance or durability.
  • Siemens offers level sensors based on various technologies, including ultrasonic, radar, guided wave, capacitive and electromechanical. Each technology has its own advantages and limitations, so choose the one that best suits your application requirements and environmental conditions.
  • Experience the ease of installation, calibration, and maintenance requirements of a level switch. Choose a switch that is easy to install and maintain, minimizing downtime and operating costs.
  • Ensure that the level switch you select complies with relevant industry standards and regulations such as ATEX, IECEx, SIL (Safety Integrity Level), and FDA regulations for food and pharmaceutical applications.
  • Siemens provides technical support and expertise to help customers select the right level switch for their specific applications.
  • Contact Siemens representatives or distributors to discuss your requirements and receive personalized advice.