Siemens Ultrasonic level transducers Echomax

ECHOMAX XPS-30 TRANSDUCER HIGH-FREQUENCY ULTRASONIC TRANSDUCER DESIGNED FOR A WIDE VARIETY OF LIQUID AND SOLID APPLICATIONS, FOR USE WITH APPROVED CONTROLLERS. INCLUDES INTEGRAL TEMPERATURE SENSOR. 1 1/2&quot, UNIVERSAL THREAD COMPATIBLE WITH 1 1/2&quot, NPT AND R 1 1/2&quot, ((BSPT), EN 10226) MEASURING RANGE: MIN. 0.6M (1.97 FT), MAX. 30M (98.43 FT) MOUNTING THREAD AND FACING: 1 1/2&quot, UNIVERSAL THREAD CABLE LENGTH: 5 M (16.40 FT) FLANGE: WITHOUT MOUNTING FLANGE APPROVALS: ATEX II 2G 1D, FM CLASS 1 DIV 2 SAA INSTRUCTION MANUAL: MULTI-LANGUAGE QUICK START

ECHOMAX XRS-5 TRANSDUCER WITH A BEAM ANGLE OF 10 DEG, THE XRS-5 PROVIDES RELIABLE, CONTINUOUS LEVEL MONITORING OF LIQUIDS AND SLURRIES IN NARROW LIFT STATIONS/WET WELLS, FLUMES, WEIRS AND FILTER BEDS. MEASURING RANGE: MIN. 0.3 M (1 FT), MAX. 8 M (26 FT) MOUNTING THREAD: 1", NPT (TAPER), ANSI/ASME B1.20.1 CABLE LENGTH: 5 M (16.40 FT) FACING: STANDARD (CSM RUBBER) APPROVALS: FM CLASS I ZONE 1, ATEX II 2G, CSA CLASS I DIV. 2, SAA EX S CLASS I ZONE 1 &, DIP PRACTICE A ZONE 20 BETRIEBSANLEITUNG: QUICK START, MEHRSPRACHIGE . FLANGE: WITHOUT MOUNTING FLANGE

ECHOMAX XRS-5 TRANSDUCER WITH A BEAM ANGLE OF 10 DEG, THE XRS-5 PROVIDES RELIABLE, CONTINUOUS LEVEL MONITORING OF LIQUIDS AND SLURRIES IN NARROW LIFT STATIONS/WET WELLS, FLUMES, WEIRS AND FILTER BEDS. MEASURING RANGE: MIN. 0.3 M (1 FT), MAX. 8 M (26 FT) MOUNTING THREAD: 1&quot, NPT (TAPER), ANSI/ASME B1.20.1 CABLE LENGTH: 30 M (98.43 FT) FACING: STANDARD (CSM RUBBER) APPROVALS: FM CLASS I ZONE 1, ATEX II 2G, CSA CLASS I DIV. 2, SAA EX S CLASS I ZONE 1 &amp, DIP PRACTICE A ZONE 20 BETRIEBSANLEITUNG: QUICK START, MEHRSPRACHIGE . FLANGE: WITHOUT MOUNTING FLANGE

ECHOMAX XRS-5 TRANSDUCER WITH A BEAM ANGLE OF 10 DEG, THE XRS-5 PROVIDES RELIABLE, CONTINUOUS LEVEL MONITORING OF LIQUIDS AND SLURRIES IN NARROW LIFT STATIONS/WET WELLS, FLUMES, WEIRS AND FILTER BEDS. MEASURING RANGE: MIN. 0.3 M (1 FT), MAX. 8 M (26 FT) MOUNTING THREAD: R 1", ((BSPT), EN 10226) CABLE LENGTH: 5 M (16.40 FT) FACING: STANDARD (CSM RUBBER) APPROVALS: FM CLASS I ZONE 1, ATEX II 2G, CSA CLASS I DIV. 2, SAA EX S CLASS I ZONE 1 &, DIP PRACTICE A ZONE 20 BETRIEBSANLEITUNG: QUICK START, MEHRSPRACHIGE . FLANGE: . DN 100 STYLE, PN 10/16, TYPE A, FLAT FACED
ECHOMAX XRS-5 TRANSDUCER WITH A BEAM ANGLE OF 10 DEG, THE XRS-5 PROVIDES RELIABLE, CONTINUOUS LEVEL MONITORING OF LIQUIDS AND SLURRIES IN NARROW LIFT STATIONS/WET WELLS, FLUMES, WEIRS AND FILTER BEDS. MEASURING RANGE: MIN. 0.3 M (1 FT), MAX. 8 M (26 FT) MOUNTING THREAD: R 1", ((BSPT), EN 10226) CABLE LENGTH: 10 M (32.81 FT) FACING: STANDARD (CSM RUBBER) APPROVALS: FM CLASS I ZONE 1, ATEX II 2G, CSA CLASS I DIV. 2, SAA EX S CLASS I ZONE 1 &, DIP PRACTICE A ZONE 20 BETRIEBSANLEITUNG: QUICK START, MEHRSPRACHIGE . FLANGE: WITHOUT MOUNTING FLANGE
ECHOMAX XPS-10 TRANSDUCER HIGH-FREQUENCY ULTRASONIC TRANSDUCER DESIGNED FOR A WIDE VARIETY OF LIQUID AND SOLID APPLICATIONS, FOR USE WITH APPROVED CONTROLLERS. INCLUDES INTEGRAL TEMPERATURE SENSOR. MEASURING RANGE: MIN. 0.3M, MAX. 10M MOUNTING THREAD AND FACING: 1", NPT ((TAPER), ANSI/ASME B1.20.1) CABLE LENGTH: 5 M (16.40 FT) FLANGE, FLUSH MOUNT: NO FLANGE APPROVALS: ATEX II 2GD,FM CLASS I DIV 2/SAA CLASS 1 ZONE 1 .
ECHOMAX XPS-10 TRANSDUCER HIGH-FREQUENCY ULTRASONIC TRANSDUCER DESIGNED FOR A WIDE VARIETY OF LIQUID AND SOLID APPLICATIONS, FOR USE WITH APPROVED CONTROLLERS. INCLUDES INTEGRAL TEMPERATURE SENSOR. MEASURING RANGE: MIN. 0.3M, MAX. 10M MOUNTING THREAD AND FACING: 1", NPT ((TAPER), ANSI/ASME B1.20.1), FOAM FACING CABLE LENGTH: 5 M (16.40 FT) FLANGE, FLUSH MOUNT: NO FLANGE APPROVALS: ATEX II 2GD,FM CLASS I DIV 2/SAA CLASS 1 ZONE 1 .
ECHOMAX XPS-10 TRANSDUCER HIGH-FREQUENCY ULTRASONIC TRANSDUCER DESIGNED FOR A WIDE VARIETY OF LIQUID AND SOLID APPLICATIONS, FOR USE WITH APPROVED CONTROLLERS. INCLUDES INTEGRAL TEMPERATURE SENSOR. MEASURING RANGE: MIN. 0.3M, MAX. 10M MOUNTING THREAD AND FACING: R 1", ((BSPT) EN 10226-1) CABLE LENGTH: 10 M (32.81 FT) FLANGE, FLUSH MOUNT: NO FLANGE APPROVALS: ATEX II 2GD,FM CLASS I DIV 2/SAA CLASS 1 ZONE 1 .
ECHOMAX XPS-15 TRANSDUCER HIGH-FREQUENCY ULTRASONIC TRANSDUCER DESIGNED FOR A WIDE VARIETY OF LIQUID AND SOLID APPLICATIONS, FOR USE WITH APPROVED CONTROLLERS. INCLUDES INTEGRAL TEMPERATURE SENSOR. MEASURING RANGE: MIN. 0.3M, MAX. 15 M MOUNTING THREAD AND FACING: 1", NPT ((TAPER), ANSI/ASME B1.20.1) CABLE LENGTH: 5 M (16.40 FT) FLANGE: NO MOUNTING FLANGE APPROVALS: ATEX II 2GD, FM CLASS I DIV 2/SAA CLASS 1 ZONE 1 MANUAL: MULTI-LANGUAGE,QUICK START

ECHOMAX XPS-15 TRANSDUCER HIGH-FREQUENCY ULTRASONIC TRANSDUCER DESIGNED FOR A WIDE VARIETY OF LIQUID AND SOLID APPLICATIONS, FOR USE WITH APPROVED CONTROLLERS. INCLUDES INTEGRAL TEMPERATURE SENSOR. MEASURING RANGE: MIN. 0.3M, MAX. 15 M MOUNTING THREAD AND FACING: 1&quot, NPT ((TAPER), ANSI/ASME B1.20.1) CABLE LENGTH: 10 M (32.81 FT) FLANGE: NO MOUNTING FLANGE APPROVALS: ATEX II 2GD, FM CLASS I DIV 2/SAA CLASS 1 ZONE 1 MANUAL: MULTI-LANGUAGE,QUICK START

ECHOMAX XPS-15 TRANSDUCER HIGH-FREQUENCY ULTRASONIC TRANSDUCER DESIGNED FOR A WIDE VARIETY OF LIQUID AND SOLID APPLICATIONS, FOR USE WITH APPROVED CONTROLLERS. INCLUDES INTEGRAL TEMPERATURE SENSOR. MEASURING RANGE: MIN. 0.3M, MAX. 15 M MOUNTING THREAD AND FACING: R 1", ((BSPT) EN 10226-1) CABLE LENGTH: 5 M (16.40 FT) FLANGE: NO MOUNTING FLANGE APPROVALS: ATEX II 2GD, FM CLASS I DIV 2/SAA CLASS 1 ZONE 1 MANUAL: MULTI-LANGUAGE,QUICK START
ECHOMAX XPS-15 TRANSDUCER HIGH-FREQUENCY ULTRASONIC TRANSDUCER DESIGNED FOR A WIDE VARIETY OF LIQUID AND SOLID APPLICATIONS, FOR USE WITH APPROVED CONTROLLERS. INCLUDES INTEGRAL TEMPERATURE SENSOR. MEASURING RANGE: MIN. 0.3M, MAX. 15 M MOUNTING THREAD AND FACING: R 1", ((BSPT) EN 10226-1) CABLE LENGTH: 10 M (32.81 FT) FLANGE: NO MOUNTING FLANGE APPROVALS: ATEX II 2GD, FM CLASS I DIV 2/SAA CLASS 1 ZONE 1 MANUAL: MULTI-LANGUAGE,QUICK START