Sick AFM60A-S4AC262144
AFM60 Absolute encoder
- High-resolution absolute encoders with up to 30 bits (AFM60) or up to 18 bits (AFS60)
- Face mount flange, servo flange, blind or through hollow shaft
- SSI, SSI + Incremental or SSI + Sin/Cos interface
Item Number:
AFM60A-S4AC262144
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Sick AFM60A-S4AC262144 is outdated.
Specification:
Part Number | 1037670 |
Connection type: | Male connector M12, 8-pin, radial |
Resolution: | 18 bit x 12 bit |
Permissible relative humidity: | 90 % (condensation of the optical scanning not permitted) |
Maximum operating speed: | 9,000 /min |
Resolution power: | 262,144 x 4,096 |
Repeat accuracy: | 0.002 ° |
Reverse polarity protection: | 1 |
Operating voltage range: | 4.5 V DC ... 32 V DC |
Moment of inertia of the rotor: | 6.2 gcm? |
Code type: | Gray |
Storage temperature range: | -40 °C ... +100 °C, without package |
Clock frequency: | 2 MHz |
EMC: | (according to EN 61000-6-2 and EN 61000-6-3) |
Permissible Load capacity of shaft: | 40 N (axial), 80 N (radial) |
Max. number of steps per revolution: | 262,144 |
Operating torque: | 0.3 Ncm (+20 °C) |
Working temperature range: | -30 °C ... +100 °C |
Initialization time: | 50 ms |
Resistance to vibration: | 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) |
Measuring step: | 0.014 ° 360 ° / number of steps |
Start up torque: | 0.5 Ncm (+20 °C) |
Electrical interface: | SSI/Gray |
Power consumption: | 0.5 W (without load) |
Interface signals: | Clock +, Clock -, Data +, Data- |
Enclosure rating: | IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side |
Bearing lifetime: | 3.0 x 10^9 revolutions |
Error limits: | ± 0.03 ° |
Resistance to shocks: | 60 g, 6 ms (according to EN 60068-2-27) |
Measuring step deviation: | ± 0.002 ° |
Shaft diameter: | 10 mm |
Max. angular acceleration: | 500,000 rad/s? |
Max. number of revolutions: | 4,096 |
Code sequence: | CW/CCW, parameter adjustable |
MTTFd: mean time to dangerous failure: | 250 a (EN ISO 13849-1) |
CW/CCW (counting sequence when turning): | L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) |
Mechanical interface: | Solid shaft with flat, Face mount flange |
SET (electronic adjustment): | H-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) |
Mass: | 0.26 kg |
People also buy
Comments
No comments yet