Sick TBS-1BSG12506NM
Temperature and Flow sensors
- Large display
- Individually programmable transistor outputs PNP or NPN, optional analog output 4 mA ... 20 mA or 0 V ... 10 V
- Round connector M12 x 1
Item Number:
TBS-1BSG12506NM
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Specification:
Part Number | 6048672 |
Maximum ohmic load RA: | ≤ 100 k&;937; (Switching outputs) < 0.5 k&;937; (output signal 4 mA ... 20 mA) |
Storage and transport temperature: | -20 °C ... 80 °C |
Seal: | NBR |
Short-circuit protection: | Outputs QA, Q1, Q2 towards M |
Process connection: | Thread G 1/4 A according to DIN 3852-E |
Maximum switching current: | 250 mA |
Relative humidity: | 45 % ... 75 % |
Messbereichskalierung: | Zero point: max. +25 % of span Full scale: max. -25 % of span |
Accuracy of switching output: | ≤ ± 0.8 % of span |
Maximum power consumption: | 70 mA |
Response time t50: | ≤ 5 s |
Ambient temperature: | -20 °C ... 80 °C |
RoHS certificate: | + |
Switching voltage: | Supply voltage [V DC] - 1 V DC |
Connection type: | Round connector M12 x 1, 4-pin |
Housing material: | Lower body: stainless steel 1.4301 (AISI 304) Plastic head: PC + ABS Input keypad: TPE-E Display window: PC |
Supply voltage: | 15 V DC ... 35 V DC |
Maximum process pressure: | 150 bar |
Protection class: | III |
Display: | 14-segment LED, blue, 4-digits, height 9 mm, display electronically turnable by 180 °, update: 200 ms |
Accuracy of analog output: | ≤ ± 0,5 % of span |
Insertion length/diameter of probe: | 250 mm / 6 mm |
Switching output function: | Normally open/normally closed, windows- and hysteresis function freely adjustable |
Display accuracy: | ≤ ± 0.8 % of span ± 1 digit |
Sensor element: | Pt1000, 2-wire, class A according to IEC 60751 |
Enclosure rating: | IP 65, according to IEC 60529 IP 67, according to IEC 60529 |
Temperature offset: | ± 3 °C |
Output signals: | 1 x PNP 1 x 4 mA ... 20 mA |
Rotatable housing: | Display against housing with electrical connection: 330 °, Housing against process connection: 320 ° |
Setting accuracy of switching outputs: | 0.1 °C |
Measuring range: | -20 °C ... 80 °C |
CE-conformity: | 2004/108/EC, EN 61326-1 emission (group 1, class B) and interference immunity (industrial application) |
Total current consumption: | 570 mA (incl. switching current) 320 mA |
Wetted parts: | Stainless steel 1.4571 (AISI 316Ti) |
Reverse polarity protection: | L+ towards M |
Response time t90: | ≤ 10 s |
Switching output: | Transistor |
Switching delay: | 0 s ... 50 s, programmable |
Isolation voltage: | 500 V DC |
Overvoltage protection: | 40 V DC |
Accuracy of sensor element: | ≤ ± (0.15 °C + 0.002 |t|) |
People also buy
Comments
No comments yet