Voltage supply | 10...30 VDC |
Reverse polarity protection | Yes |
Consumption w/o load | ≤100 mA (24 VDC) |
Operating temperature | -25...+85 °C -40...+85 °C (optional) |
- Overview
- Datasheet
- Alternative numbers
- Comments
Operating temperature | -25...+85 °C -40...+85 °C (optional) |
Rotor moment of inertia | 20 gcm² |
Reverse polarity protection | Yes |
Programmable parameters | Steps per revolution Number of revolutions Preset Scaling Rotating direction |
Emitted interference | DIN EN 61000-6-4 |
Sensing method | Optical |
Interference immunity | DIN EN 61000-6-2 |
Relative humidity | 95 % non-condensing |
Number of turns | ≤65536 / 16 bit |
Protection DIN EN 60529 | IP 54 IP 65 |
Steps per turn | ≤8192 / 13 bit |
Weight approx. | 500 g |
Voltage supply | 10...30 VDC |
Materials | Housing: steel Flange: aluminium Bus cover: zinc die-cast |
Diagnostic functions | Position or parameter error Multiturn sensing |
Size (flange) | ø58 mm |
Approval | UL approval / E63076 |
Connection | Bus cover |
Device adress | Rotary switch in bus cover (type-specific) |
Incremental output | 2048 pulses A90°B (optional) |
Absolute accuracy | ±0.025 ° |
Resistance | DIN EN 60068-2-6 Vibration 10 g, 16-2000 Hz DIN EN 60068-2-27 Shock 200 g, 6 ms |
manufacter SKU | GXMMS |
Starting acceleration | ≤1000 U/s² |
Operating speed | ≤6000 rpm (mechanical) ≤6000 rpm (electric) |
Status indicator | DUO-LED integrated in bus cover |
Code | Binary |
Shaft type | ø12 mm (blind hollow shaft) ø14 mm (blind hollow shaft) ø15 mm (blind hollow shaft) |
Starting torque | ≤0.015 Nm (IP 54) ≤0.03 Nm (IP 65) |
Interfaces | CANopen® DeviceNet EtherCAT EtherNet/IP PoE Profibus PROFINET POWERLINK SAEJ1939 SSI |
Function | Multiturn |
Consumption w/o load | ≤100 mA (24 VDC) |
Initializing time typ. | 250 ms after power on |
Code sequence | CW/CCW programmable |